Loading...
HomeMy WebLinkAboutPH 1 MODEL CONST CODES 11-16-87PUBLIC HEARING TO: FROM: SUBJECT: WILLIAM A. HUSTON, CITY HANAGER CONHUNITY DEVELOPMENT DEPARTT4ENT ORDINANCE NO. 995 TO ADOPT UPDATED EDITIONS OF THE MODEL CONSTRUCTION CODES #ITH LOCAL MODIFICATIONS. ii RECOMMENDATION: It is recommended that the City Council take the following"actions' 1. Adopt Resolution No. 87-133 setting forth flndfngs which make certatn modifications .and changes to the Untform Buildtng Code, Untform Plumbing Code, and the Nattonal Electrical Code reasonably necessary for houstng occupancies. 2. M.O. - Hold ftrst readtng of Ordinance 995 by title only. 3. M.O. - Introduce Ordinance 995. BACKGROUND: il , The City's Planntng and Butldtng Divisions are currently using the 1979 editions of model construction codes published by the !nternattonal Conference of Buildtng Officials. The state has recently adopted the 1985 editions of the model construction codes and tt is now appropriate that the City adopt by ordinance the following: Uniform Administration Code (1985 Edition) Uniform Building Code (1985 Edftt.on) Uniform Security Code (1985 Edition) State Historical Code (1985 Edition) Uni form Mechanical Code (1985 Edt ti on) Uniform Plumbing Code (1985 Edition) Uniform Solar Energy Code (1985 Edition) National Electrical Code (1987 Edition) promulgated by the National Fire Protection Association. Uniform Swimming Pool, Spa and Hot Tub Code (1985 Edition) Uni form Si gn Code (1985 ~Edi ti on) Uniform Housing Code (1985 Edition) Uniform Code for the Abatement of Dangerous Buildings {1985 Edition) The proposed Ordinance adopts all Codes which earlier editions have been in use previously by the Planning and Building Codes. ,, J City Council Meeting November 16, 1987 Page two ' ino~.~ in het ght above grade. 2. Permtts would be requtred for all on-stte construction - curbs, lots, sidewalks, etc. The Model Construction Codes may be modified to address local conditions or concerns provided that any local modification is more restrictive than the model codes. A resolution is attached setting forth findings which justify those recommended modtflcations or changes to the Uniform Building Codes. Major modifications or changes to the code can be summarized as follows: '~J~~ 1. Permits would be required for the construction of fences/walls over parki nf~s~~ 3. Permit fee schedules could be adopted and modified by City Council Resolution as needed. 4. One hour construction may In some instances be compensated with a fire sprinkler system. 5. All roofs be fire treated, Class C even for repair work. 6. Elevator inspection and permits be obtained from the State of California. 7. Asbestos water pipes be prohibited. 8. Modification of our swimming pool code has been made as to be more in agreement with neighboring cities and the State code. The City Attorney has reviewed the proposed ordinance and resolutions and has approved them as to form and content. "Christine A. S~ingleton, Director of Community Development LD'CAS- ts' jk Attachments- Ordinance 995 Resolution No. 87-133 Corn munity Development Department 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 ORDINANCE NO. 995 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TUSTIN AMENDING SPECIFIED SECTIONS OF ARTICLE 8 OF THE TUSTIN CITY CODE ADOPTING 1985 CODES AS THE BUILDING REGULATIONS OF THE CITY OF TUSTIN The City Council of the City of Tustin does hereby ordain as follows' Section 1- Chapter one of Article 8 of the Tusttn City Code is hereby repealed in its entirety, and a new Chapter 1, Article 8 is hereby added in place thereof to read as follows- CHAPTER 1 BUILDING CODE 8100 - Adoption of 1985 Uniform Administrative Code Except as provided in this chapter, that certain administrative code known, and designated as the Uniform Administrative Code, 1985 Edition, published by the International Conference of Building Officials, shall be and become the administrative code of the City, providing for the administration and enforcemeflt of the technical codes adopted by the City. One copy of the Uniform Administrative Code has been deposited in the office of the City Clerk, and shall be at all times maintained by the City Clerk for use and examination- by the public. 8101 Amendment of the 1985 Uniform Administrative Code The 1985 Uniform Administrative Code is hereby amended as follows- (A) Section 104(b) is amended by the addition of a paragraph at the end thereof to read as follows' Notwithstanding the ordinances effective on the date of the construction of a building, conditions requiring subsequent alterations, additions or repairs to such buildings included in and required by subsequent resolutions of the City Council, City Planning Commission or City Planning Agency, or by the Statutes of the State of California, shall be enforceable through the provisions of Section 108 of the Uniform Administrative Code. (B) Section 105 Definitions Whenever any of the following names or terms are used in the Uniform Administrative Code, each such name or term shall be deemed and construed to have the meaning ascribed to it in this section as follows' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page le ® Se "Building Code" - means Article 8102 of this code as amended. "Electrical Code" - means article 8400 of this code as amended. "Plumbing Code" - means Arttcle 8300 of thts code as amended. "Mechanical Code" - means Article 8200 of this code as amended. "Board of Appeals" - means the Planntng Commlsslon of the Ctty of Tusttn. (C) Sectlon 202 ts amended by adding Subsection (k) to read as follows' Ke Infractions. As a law enforcement offtcer (as authorized by) Sectton 202(a) and (b), and as authorized by the State Penal Code Secttons 17, 19c, 19d, 836.5, 840, 841, 853.6 and 1042, the Butldlng Offtclal of thts Ctty is authorized to tssue citations. These citations (may be) issued to persons who have committed an Infraction tn violation of: (1) A state statute of the California Administrative Code tn which the statute or'CMA requires enforcement by the local building official; (2) City Council adopted edition of the Uniform Building Code, Uniform Mechanical Code, Uniform Plumbing Code, or-ICBO Plumbing Code, Uniform Swimming Pool Code, Uniform Solar Energy Code; and (3) current zoning code as adopted by ordinance by the City Council which provides for enforcement by the Building Official. The Building Official or his authorized representative shall issue citations for infractions. (D) Section 205 is amended to read as follows' Violations. No person shall violate any provision, or fail to comply with any of the provisions of this Code, or of any Code adopted herein by reference. Any person violating any of the provisions or failing to comply with any of the mandatory requirements of this Code, or any Code adopted by reference 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26 27 28 Ordinance No. 995 Page three hereln, unless otherwlse specified In thts Code, may be subject to enforcement action as more specifically set forth in Part 2 of the Tustln City Code, entitled "Penalty Provisions". Each such person violating any provision or failing to comply with any of the requirements shall be guilty of a separate offense, and-each day during any portion of which any violation of any provision of this Code, or any Code adopted by reference herein, is committed, continued or permitted by such person, shall constitute a separate offense, and shall be punishable accordingly. Provided further that each such person violating a provision which limits the time an act may be permitted or continued, each such period or portion thereof of which any violation of such provision is committed, continued or permitted by such person shall constitute a separate offense, and shall be punishable accordingly. In addition to the penalties hereinabove provided, any condition caused or permitted to exist in violation of any of the provisions of this Code, or of any Code adopted by reference herein, shall be deemed a public nuisance and may be summarily abated as such by the City, and each day ~uch condition continues shall be regarded as a new and separate nuisance and offense." (E) Section 301 is amended by changing subsection (b) and adding ~ubsections (c), (d), and (e) to read respectively as follows: (b) (1) The Uniform Administrative Code is amended by deleting subsection B and E and renumbering the remaining subsections accordingly, so that building permits are required for all fences and retaining walls over thirty six inches in height above grade. (c) The Building Official shall issue building permits for construction, demolition, addition, alteration and installation of required on-site improvements such as, but not limited to, curbing, walks, stairs, ramps, parking lots, driveways, irrigation systems, lighting systems, landscaping and incidental light grading (not requiring a grading permit, Chapter 70). These permits will be issued when the on-site work does not otherwise require a building permit. All such above work shall be as authorized and/or required as 'a condition of approval by the City Council, City Planning Agency, City Planning Commision, Director of Community Development and/or City. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page four (d) (1) Relocatlon of Building: No butldlng or structure shall be moved or relocated unless and unttl the necessary permtts to relocate the butldtng or structure have been tssued by the Butldtng Official. (2) Upon request to relocate a butldtng or structure, the Butldtng Official shall collect from the owner or his representative for an Investigative Inspection. The Butldtng Offtctal shall determine tf the butldtng is capable in his judgment of being moved. In addition, tf the butldlng fs to be moved tnto the Ctty, or relocated within the City, the investigative inspection shall determine if the building will satisfy the zoning and building code requirements. He shall then report in writing, all facts, judgments and information, to advise the owner or his representative, the requirements 'and conditions to relocate the building. (3) A permit to relocate the building shall be issued only to a building, moving, wrecking contractor, C-21, to move the building. Concurrent with the relocation permit, grading, building, electrical, plumbing and mechanical permits, as necessary, shall be issued for necessary site work and/or building rework. Permits shall be issued, after the Building Official has · approved drawings describing the scope of work to be constructed, altered, repaired, and such other work, to place the relocated building in such conditions that it conforms to the requirements of the state law, ordinances, and the City Building and Zoning Codes. (4) If the relocated building or structure would be unlawful, dangerous or defective and there is no practical remedy or correction which can effectively be made in the judgment of the Building Official, or the Building. Official's conditions have not been complied with, the relocation permit shall be denied. (5) The Building Official shall, in issuing any relocation permit, impose therein such terms and conditions, including a cash bond deposit, as may be necessary to ensure compliance with the requirements of all state laws, City ordinances and of the city Building and Zoning Codes. The terms and conditions upon which 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page fi ve each permit is granted shall be specified in writing in the permit, or appended in writing thereto. (6) If the relocation permit is not issued within ninety (90) days after notice to the applicant by the Building Official, a new investigation fee shall be paid and an additional inspection and written report be made before the relocation permit may be issued. (7) Prior to permit issuance, a refundable cash deposit shall be collected to reimburse the expense to the City for the Building Official to demolish the building or structure, and dispose of the debris in a public dump or other action as required of the Building Official as stated elsewhere. The cash deposit shall be Two Thousand Five Hundred Dollars {$2,500.00); plus One Dollar and Twenty-five cents ($1.25) per square foot over one thousand (1,000) square feet. In addition, the valuation of the improvement permits shall be added to the cash deposit. (8) The building relocation permtttee shall take out and maintain during the life of the permit, such public liability and property damage insurance as shall protect the City of Tustin, its elective and appointive boards, officers, agents and employees, contractors and any subcontractors, from claims for damages to public and private property, and for personal injury, including death, resulting from the operations under the permit for building relocation, whether such operations are by the permittee, or by anyone directly or indirectly employed by the permittee. The amounts of said insurance shall be as follows: a. Public Liability Insurance. In an amount not less than Five Hundred Thousand Dollars ($500,000.00) for injuries, including, subject to the same limit for each person, in an amount not less than One Million Dollars ($1,000,000.00) on account of any one occurrence. b. Property Damage Insurance. In an amount of not less than Two Hundred Thousand Dollars 1 2 3 4 5 6 7 8 9 .. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page six ($200,000.00) for damage to City property, or the property of each person on account of any one occurrenoe. (9) Contractor shall furnish satisfactory proof of carriage of the insurance required, a certificate of insurance by his insurance carrier naming the City of Tustin and its employees additional insureds, and legal assurance that each carrier will give the City at least thirty (30) days prior written notice of the cancellation of any policy during the effective period of the permit. The insurance certificate shall be as prescribed by the City of Tustin. (10) Bond Condition. Every cash bond in the amount determined by the Building Official deposited pursuant to this Section, shall be conditioned as follows: a. That each and all of the terms and conditions of the relocation permit shall be completed'as approved by the Building Official. be That all of the work required to be' done pursuant to the conditions of the relocation permit, shall be fully performed and completed within the time limit specified in the relocation permit; or if no time limit is specified, within ninety (90) days after issuance of permit. The time limit herein specified, or the time limit specified in any permit, may be extended for good and sufficient cause beyond the control of the permittee, by the Building Official. No such extension shall be a release from any cash bond or insurance policy. There shall be no additional extension. (11) Default in Performance. a. Whenever the Building Official shall find that a default has occurred in the performance of any term or condition of any permit, written notice (certified mail, return receipt requested) thereof shall be given to the owner and/or permt tree. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 .16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page seven be Such notlce shall specify the' work to be done, the estimated cost therof, and the period of time deemed by the Butldlng Official to be reasonably necessary for the completion of such work. Ce After receipt Of such notice, the owner and/or permtttee thereof specified shall cause the required work to be performed. Should the owners refuse or fail therein, the Building Official shall, with no liability to the City or its employees, proceed by such mode as the Buildt.ng Official deems convenient to cause the building to be demolished or completed. de Should the building, while being moved, be wrecked or abandoned in the public right-of-way and the Chief of Police declare the building to be dangerous to the public, the Building Official, in the interest of public safety shall, without delay, and with no liability to the City or its employees, proceed by such mode as the Building Official deems convenient-to cause the bui 1 ding to be removed from the publ t c right-of-way, including demolition. e® Should the building, while being moved, be abandoned on publtc or private property and the property owner request the Building Official to remove or dispose of the building, the Building Official shall endeavor to have the building owner and/or permittee move or dispose of the building. The Building Official shall, after reasonable time (but no less than thirty (30) days), and with no liability to the City or its employees proceed by such mode as the Building Official deems convenient to cause the building to be demolished or the required work to be performed and completed. (e) (1) Demolition of building or structure: No building or Structure shall be demolished unless and until the necessary permits to demolish the building or structure have been issued by the Building Official. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page etght (2) Prtor to tssutng any permtts, tn additton to the requirements of Section 4409 of the Uniform Building Code, the Butldlng Offtclal wtll ensure llfe and property is reasonably protected. A refundable cash depostt shall be collected, to reimburse the expenses to the City should the Building Offtctal be required to demoltsh the butldfng or structure or any portton remaining thereof, and dtspose of the debris In a publlc dump and/or to repatr or clean public property damaged or not cleaned by the permtttee. (3) The cash depostt shall be Two Thousand Five Hundred Dollars ($2,500,00) plus One Dollar and Twenty-five cents ($!,25) per square foot for each square foot over one thousand (!,000) square feet, (4) The Building Official shall, in issuing any demolition permit, impose therein such terms and conditions, including a cash bond deposit, as may be necessary to ensure compliance with the requirements of all state laws, City ordinances, and of the City Building and Zoning Codes. The terms and conditions upon which each permit is granted shall be specified in writing in the permit, or appended in writing thereto. (5) Default in Performance. a. Whenever the Building Official shall find that a default has occurred in the performance of any term or condition of the demolition permit, or has soiled or damaged public property, written notice thereof shall be given to the owner and/or permi tree. b. Such notice shall specify the work to be done, the estimated cost thereof, and the period of time deemed by the Building Official to be reasonably necessary for the completion of such work. c. After receipt of such notice, the owner and/or permtttee thereof specified shall cause the required work to be performed. Should the owner refuse or fail therein, the Building Official shall proceed by such mode as he deems 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 '27 28 Ordinance No. 995 Page nine convenient, to cause the building to be demolished but no 11ability shall be tncurred theretn, other than for City expenses deducted from the cash depostt. de Upon completion of the demolition work, the cash deposit shall be refunded, less that portion required to reimburse the City for demolition, repairs, or clean-up expenses due to the default of the permtttee. (Fl Section 303 is amended by adding subsection (fl to read respectivelY as follows: (fl Change of Contractor or of ownership. A permit issued hereunder shall expire upon a change of ownership or a change of contractor regarding the building, structure or grading for which said permit was issued if the work thereon has not been completed, and a new permit shall be required for the completion of. the work. (Gl Section 304 (b) the first paragraph is amended to read as , ii - -- follows: (b) Permit Fees Permit fee schedules for each technical code adopted bY the City shall be that schedule which the City Council may from time to time adopt by resolution. No fees will be required for work financed by the City of Tustin. (H) Section 304(c) Plan Review Fees is amended to read as follows: When a plan or other data are required to be submitted by Subsection (c) of Section 302, a plan review fee shall be paid at the time of submitting plans and specifications .for review. Plan Review Fees schedules for each technical code adopted by the City shall be that schedule which the City Council may from time to time adopt by resolution. (Il Section 304(e) Investigation Fees - Work without a permit: is amend'eld als follows: le Investigation. Whenever any work for which a permit is required by this Code has been commenced without first obtaining said permit, a special investigation shall be made before a permit may be issued for such work. 1 Ordlnance No. 995 Page ten 5 6 7 8 9 10 11 12 13 14 15 1G 20 21 22 23 2~ 25 2~ 2. Fee. An Investigation fee, in addition to the permit fee, shall be requtred and collected whether or not a permtt ts then or subsequently tssued. The Investigation fee shall be equal to the amount of the perm1 t required by thts Code. The mi ntmum Investigation fee shall be tn no case less than stxty dollars ($60.00). The payment of such Investigation fee shall not exempt any person from compliance wtth all of the provisions of etther thts Code or the technical codes or from any penalty described by law. (J) Sectton 307(b) ts amended to read as follows: Temporary Connections. The Building Official will authorize energy connection only after all work for the project, as shown on the approved drawings, is completed as required by various applicable state laws, ordinances, and codes; and as required by the City Council, the City Planning Commission, City Planning Agency, the Director of Community Development, the City Engineer, the Director of Public Works, and/or the Fire Marshal. EXCEPTION: The Building Official may authorize energy connection of the building service equipment only after the owner or permittee has made a written request therefore, showing justification for the connections and after all fees and deposits have been paid, if the Building Official finds that no substantial hazard will result. The cash deposit shall be in the amount of the valuation of the uncompleted work. Should the work not be completed prior to the date approved by the Building Official, the Building Official will order the work completed. All of the expenses to the City for con~leting the work shal.1 be deducted from this cash deposit. 8102 - ADOPTION OF THE 1985 UNIFORM BUILDING CODE AND 1985 UNIFORM BUILDING CODE STANDARDS Except as provided in this chapter, those certain building codes known and designated as the Uniform Building Code and the Uniform Building Code Standards, 1985 Editions, including the appendix to the Uniform Building Code published by the International Conference of Building Officials, shall be and become the building codes of the City for regulating the erection, construction, enlargement, alteration, repair, moving, removal, demolition, conversion, occupancy, equipment, use, height, area and maintenance of all buildings and/or structures in the City. One copy each of the Uniform Building Code, its appendix and the Uniform 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 2O 21 22 23 24 25 26 27 28 Ordinance No. 995 Page eleven Butldtng Code Standards, has been deposited fn the office of the Ctty Clerk, and shall be at all ttmes maintained by the Ctty Clerk for use and examtnatt on by the publ tc. A® Part I. Part I is deleted from the Uniform Building Code. · 8103 - AMENDMENTS TO THE UNIFORN BUILDING CODE A. The 1985 Uniform Building Code is hereby amended as follows' B. Section 508 is amended to read as follows' When one-hour fire-resistive construction throughout is required by this code, an approved automatic sprinkler system, as specified in Chapter 38, may be substituted, provided such system is not otherwise required throughout the building. EXCEPTIONS: 1.) An approved automatic sprinkler required by - Section 3802 (b) 5 may be substituted. 2.) Such substitution shall not waive nor reduce required fire-resistive construction for: Occupancy separations (Section 503[c]). 2. Exterior wall protection due to proximity of property lines (Section 504 [B]). 3. Area separations (Sectio 505[e]). 4. Shaft enclosures (Section 1706). 5. Corridors (Section 3305 [g] and [h]). 6. Stair enclosures (Section 3309). 7. Exit passageways (Section 3312[a]). 8. Type of construction separation (Section 1701). g. Atriums constructed in accordance with Section 1715. C. Subsection 3202 (b) is amended to read as follows: (1) Fire Retarding when required. Roof coverings shall be fire retardant, except for Occupancy Group M where ordinary roof coverings (as defined in Section 3203(f)) may be used. Skylights shall be constructed as required in Chapter 34. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page t~el ve Penthouses shall be constructed as required in Chapter 36. For use of plastics in roofs, see Chapter 52. For Attics; Access and Area, see Section 3205. For Roof Drainage, see section 3207. For solar energy collectors located above or upon a roof, see Section 1714. (D) Subsection 3203(f), to read as follows' (f) Ordinary roof covering. An ordinary roof covering shall be any of the following roofings: 1. Any roof covering listed in Section 3203(e). 2. Any built-up roofing assembly not less than Class C roofing. 3. Any mineral aggregate surface built-.up roof for application to roof having a slope of not more than three (3) inches to twelve (12) inches applied as specified in Section 3203(d)2, consisting of not less than the *fol 1 owl ng: Base sheet and plies Three (3) layers of Type 15 organic or inorganic fiber felt; and Surfacing materials; Three hundred (300) pounds per roofing square of gravel or other approved surfacing material; or Two hundred fifty (250) pounds per roofing square of crushed slag in fifty (50) pounds of asphalt; or Stxty (60) pounds of pi tch. 4. Any prepared roofing not less than Class C roofing. 5. Wood shingles (treated). 6. Wood shakes (treated). 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26 27 28 Ordinance No. 995 Page thtrteen EXCEPTION: Notwithstanding the provisions of Sectton 104(b), hereof, once tn any twelve-month pertod of ttme, any extsttng roof covertng may be replaced by the use of in ktnd roof covertng where the replacement thereof does not exceed twenty-five (25) percent of the existing gross roof area. (E) Sectton 3802 (b) ts amended by addtng subsection 5 to read respectively as follows: ® In all new buildings or structures when the gross square footage thereof exceeds 6,000 square feet or more than two (2) stortes tn hetght regardless of area separation walls. (F) Sectton 3802 is amended by adding subsection (h) to read respectively as follows' (h) Group R, Dtvtston I Occupancies. An automatic sprinkler system shall be Installed in Group R, Division ! Occupancies. (G) Section 3804 subsection 2 is amended to read as follows' 2. Sprinklers shall not be installed when the applfcatton of water or flame and water to the contents may constitute a sertous ltfe or ftre hazard. Other approved automatic fire-extinguishing systems shall be Installed in these areas when the area is requtred to be protected by other secttons of tht s Code. (H) Chapter 41 is amended to read as follows: For the purposes of establishing minimum standards to make buildings resistant to unlawful entry, all provisions of the 1985 Edltlon, Untform Buildtng Securtty Code, adopted and published by the Internatlonal Conference of Butldlng Officials, of whtch one copy has been and now is ftled in the offtce of the Ctty Clerk of the Ctty of Tusttn, are hereby adopted and incorporated heretn as fully as though set forth tn full heretn, save and except such portions as are hereinafter deleted, modtfted or amended. (1) Sectton 4101 ts amended as follows: The purpose of thts Code 'is t~ establish mtnimum standards to make all buildings resistant to unlawful entry. (2) .Sectlon 4102 ts amended as follows: The provisions of this chapter shall apply to opentngs tnto all buildings, including dwelling untts wtthin apartment houses of Group R, Dtvtston I Occupancies and Group R, Otvtston 3 · Ordinance No. 995 Page fourteen 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Occupancies, and to openings between attached garages and dwelling units. Except for vehicular access, door openings in enclosed attached garages shall be in accordance with the provisions of this Chapter. EXCEPTIONS: (1) An opentng in an exterior wall when all porttons of such openings are more than twelve (12) feet vertically or six (6) feet horizontally from an accessible surface of any adjoining yard, court, passageway, public way, walk, breezeway, patio, planter, porch or similar area. (2) An opening in an exterior wall when all portions of such 'openings are more than twelve (12) feet vertically or six (6) feet horizontally from the surface of any adjoining roof, balcony, landt-ng, stair tread, platform or similar structure or when any portion of such surface is itself more than twelve (12) feet above an accessible surface. (3) Any opening in a roof when all portions of such roof are more than twelve (12) feet above an accessible surface. (4) Openings where the smaller dimension is six (6) inches or less, provided that the closed edge of such openings is at least thirty-six '(36) inches from the locking device of the door or window assembly. (5) Openings protected by required fire door assemblies having a fire endurance rating of not less than forty-five (45) minutes. (3) Section 4110, Garage Type Doors' Rolling Overhead, Solid Overhead, Swinging, Sliding or Accordion Style, is added to read as follows' The above described doors shall conform to the following (3) Fiberglass doors shall have panels a minimum density of six (6) ounces per square foot from the bottom of the door to a height of seven (7) feet. Panels above seven (7) feet and panels in residential structures Ordinance No. 995 Page ftfteen 3 4 5 6 7 8 9 10 11 12 13 1.4 15 16 20 21 22 23 2~ 25 2¢ 27 28 shall have a denstty of not less than five (5) ounces per square foot. (4) Overhead doors shall be equipped with bolts which shall be capable of utilizing padlocks with a minimum nine-thirty-seconds-inch shackle. (5) Doors utilizing a cylinder lock shall have a minimum five-pin tumbler operation with the bolt or locking bar extending into the receiving guide a minimum of one (1) inch. (6) Doors that exceed sixteen (16) feet in width shall have two (2) lock' receiving points, or if the door does not exceed nineteen (19) feet, a single bolt may be used if placed in the center of the door with the locking point located either in the floor or door frame header. (7) Slide bolt assemblies shall have a frame a minimum of .120 inches in thickness, a bolt diameter a minimum of one-half (1/2) inch and protrude at least one and one-half (1 1/2) inches into the receiving guide. A bolt diameter of three eights (3/8) inch may be used in a residential building. (8) Slide bolt assemblies shall be attached to the door with bolts which are nonremovable from the exterior. Rivets shall not be used to attach such assemblies. (9) Padlocks used with exterior mounted slide bolts shall have a hardened steel shackle, a minimum of nine thirty-seconds (9/32) inch in diameter with heel and tow locking and a minimum five-pin tumbler operation. The key shall be nonremovable when in an unlocked post ti on. (4) Section 4111, Special Residential Building Provisions, is added to read as follows' The following special provisions shall apply to all residential dwellings (R-l, R-3 and M-l)- (1) Except for vehicular access doors, all exterior swinging doors of any residential building and 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Ordinance No. 995 Page sixteen attached enclosed garages, Including the door leadtng from the garage area tnto the dwelltng untt, shall be equtpped as follows' a. ^11 wood doors shal] be of sol t d core construction wtth a mtntmum thickness of one and three-fourths (1 3/4) inches, or with panels not less than nine-sixteenths (9/16) of an tnch thtck. b. A slngle or double door shall be equtpped with a double or stngle cyltnder deadbolt havtng a mlnlmum protection of one (1) 1rich and an embedment of at least three-fourths (3/4) 1rich tnto the strike receiving the bolt. The bolt shall be constructed so as to resist cutttng tool attacks. The cyltnder shall have a cyltnder guard, a minimum of ftve (5) pin tumblers, and shall be connected to the t nner portions of the lock by connecting screws of at least one-fourth (1/4) of an inch in diameter. (The provisions of the preceding paragraph do not appty where panic hardware is required or an equivalent device is approved by the enforcing authority. Further, a dual locktng mechanism, constructed so that both the deadbolt and latch can be retracted by a stngle actton of the tnstde door knob or lever, may be substituted provtded tt meets all other specifications for locktng devices.) c. The tnactfve leaf on metal frame double doors shall be equipped with flush bolts havtng a mtntmum protection of five-eighths (5/8) of an tnch at the top and bottom of the leaf. On wood frame double doors, the projection shall be a mtnlmum of one (1) tnch. d. Glazing in exterior doors or within forty (40) inches of a door locking mechanism shall be of fully tempered glass or rated burglary resistant glazing, except where double cylinder deadbolts are installed. e. All front exte'rtor doors shall be equipped with a wi de angle (one hundred eighty [180] degrees) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26 27 28 Ordinance No'. 995 Page seventeen door viewer, except where clear vision panels are Installed. (2) Street numbers and other tdenttfylng data shall be displayed as follows: (3) a. Every dwelling unit shall display a street number in a prominent location on the street side of the residence in such a posit*ion that the number is easily visible to approaching emergency vehicles. The numerals shall be no less than three (3) inches in height and shall be of a contrasting color to the background to which they are attached and illuminated during hours of darkness. °. b. There shall be positioned at each entrance of each R-1 occupancy complex an illuminated diagraphic representation of the complex which shows the location of the vi ewer and the unit designations within the complex. In addition, each individual unit within the complex shall display a prominent identification number which is easily visible to approaching vehicular and/or pedestrian traffic. Lighting in R-1 type occupancies shall be as follows: a. Aisles, passageways and recesses related to and within the building complex shall be illuminated with an intensity of at least twenty-five hundredths (.25) of a footcandle at the ground level during the hours of darkness. Lighting devices shall be protected by weather and vandal i sm resistant covers. be Open parking lots and carports shall be provided with a maintained minimum of one (1) footcandle of light on the parking surface during hours of darkness. Lighting devices shall be protected by vandal resistant covers. These lighting devices ,shall be automatically energized during hours of darkness. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page eighteen (c) Each residential untt of R-1 type occupancies shall have an enclosed parking space with a garage door equipped as in Section 4106 of this Chapter. 5. Sectton 4112, Spectal Commercial Butldtng Provisions other than Type R-l, R-3 and M-l, is added to read as follows: The following special provisions shall apply to commercial buildings: (A) All exterior swinging doors shall be equipped with a double or single cylinder deadbolt. The bolt shall have a minimum projection of one (1) inch and will have an embedment of at least three-quarters (3/4) of an inch into the strike receiving the bolt. The bolt shall be constructed so as to resist cutting tool attacks. The cylinder shall have a cylinder guard, a minimum of five (5) pin tumblers and shall be connected to the inner portion of the lock by connecting screws of at least one-quarter-inch diameter. (The provisions of the preceding paragraph do not apply where panic hardware is required or an equivalent device is approved by the enforcing authori ry. ) (B) Wood doors shall be of solid core construction and have a minimum thickness of not less than one and three-fourths (1 3/4) inches. (C) Hollow metal doors shall be constructed of a minimum sixteen (16) U.S. gauge steel and have sufficient reinforcement to maintain the designed thickness of the door when any locking device is installed; such reinforcement being able to resist collapsing of the door around the locking device. (O) The inactive leaf on metal frame double doors shall be equipped with flush bolts having a minimum projection of five-eighths (5/8) of an inch at the top and bottom of the leaf. On wood frame doors, the projection shall be a minimum of one (1) inch. (E) Double doors shall have an astragal constructed of steel a minimum of .125 of.an inch thick which will cover the opening between the doors. The astragal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page nineteen shall be a mfntmum of two (2) Inches wtde and extend a mtntmum of one (1) inch beyond the edge of the door to whtch it ts attached. Tile astragal shall be attached to the outstde of the acttve door by weldtng or nonremovable bolts spaced apart on not more than ten-tnch centers. (F) Any glaztng utlltzed wtthln forty (40) tnches of any locking mechanism on a door, other than a double cylinder deadbolt, shall be secured as follows: 1. Fully tempered glass or rated burglary resistant glazing; or . Iron or steel bars of at least one-half-inch round or one-inch by one-fourth-inch flat metal spaced not more than five (5) inches apart and secured on the inside of the building; or . Iron or steel grills of at least one-eighth-inch metal with a maximum two-inch mesh, secured on the inside of the building. Items 1. and 2. above shall not interfere with the operation of opening windows if such windows are required to be openable by this Code. (G) Aluminum frame swinging doors shall conform to the following: 1. The jamb shall be so constructed or protected to withstand sixteen hundred (1600) pounds of pressure in both a vertical distance of three (3) inches and a horizontal distance of one (1) inch each side of the strike, so as to provide violation of the strike. 2. The bolt projection shall be a minimum of one and one-half (1 1/2) inches; or, a hook shaped or similar bolt may be used as long as it engages the strike sufficiently to resist jamb spreading. (H) In multiple occupancy office building, all entrance doors to individual office suites shall meet the requirements for exterior doors. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Pa ge twenty (I) Where pantc hardware ts requtred by thts Code, or Title 19, California Admtnt.strattve Code, it shall be equipped and installed as follows: 1. There shall be a minimum of two (2) locking points on'each door; or ® On single doors, panic hardware may have one locking point which is not to be located at either the top or 'bottom rails of the door frame. The door shall have an astragal constructed of steel .125 inches thick which shall be welded or attached with nonremovable bolts to the outside of the door. The astragal shall extend a minimum of two (2) inches wide and extend a minimum of one (1) inch beyond the edge of the door; or ® Double doors containing panic hardware shall have an astragal attached to the doors at their meeting point which will close the opening between them but not interfere with the operation of either door. (O) Exterior transoms or windows shall be deemed accessible if less than twelve (12) feet above ground or adjacent to any pedestrian walkway. Accessible windows and transoms not visible from a public or private throughfare and having a pane or opening exceeding ninety-six (96) square inches shall be constructed or protected as follows: o Fully tempered or rated burglary resistant glazing shall be used; or 2. Interior steel or iron bars of at least one-half-inch round or one-inch by one-quarter- inch flat steel or iron may be used if spaced not more than five (5) inches apart and secured by bolts which are nonremovable from the exterior; or Interior iron or steel grills of at least one-eighth-inch metal having a mesh of not more than one (1) inch may be used if secured with bolts which are nonremovable from the exterior. Ordinance No. 995 Page ~enty-one 3 4 5 6 7 Items 1. and 2. above shall not interfere wi th the opera ti on of windows if such windows are required to be operable by this Code. The bars or grillwork shall be capable of quick opening f~om the inside only. (K) All hatchway openings on the roof of any building used for business purposes shall be secured as follows: 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 ® If the hatchway is of wooden material it shall be covered on the inside with a minimum sixteen-gauge sheet metal or its equivalent, attached wi th screws. 2. The hatchway shall be secured from the inside with a slide bar or slide bolt. The slide bar or slide bolt shall automatically release when actuated by smoke or heat from a fire. ® Outside hinges on all hatchway openings shall be provided with nonremovable pins and shall use nonremovable screws for mounting.. (L) All exterior air duct or air vent openings exceeding ninety-six (96) square inches shall be secured by one of the following means: ® Iron or steel bars of at least one-half-inch round or one-inch by one-fourth-inch flat metal, spaced no more than five (5) inches apart and secured by bolts which are nonremovable from the exterior; or ® Iron or steel grills having a minimum thickness of one-eighth-inch, a mesh of net not more than one-inch, and secured by bolts which are nonremovable from the exterior. 3. The above must not interfere wi th any venting requirements. (M) Permanently affixed ladders leading'to roofs shall be covered wi th sheet metal to a height of ten (10) feet. If the ladder protrudes more than six (6) inches from the building, the sides must also be 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page. t~enty-t~o covered with sheet metal. The covering shall be locked against the ladder by means of a case hardened hasp, secured with nonremovable bolts or screws. If hinges are of the pin type, they shall be equipped with nonremovable pins. Padlocks shall have hardened steel shackles, heel and toe locking, a minimum of five (8) pin tumblers in its operation and a nonremovable key when in an unlocked position. (N) All exterior commercial doors shall be illuminated with a minimum of one (1) footcandle of light. Such lights shall be maintained during hours of darkness and be protected by vandal resistant covers. (0) Open parking lots providing more than ten (10) parking places and for use by the general public shall be provided with a maintained minimum of one (1) footcandle of light on the parking surface from dusk until the termination of business every operating day. (P) Every commercial building shall display an address number in a-prominent position so that it shall be easily visible from the street. The numerals in these numbers shall be no less than six (6) inches in height, of a color contrasting to the background and located so that they may be clearly seen and read. Any business which affords vehicular access to the rear of the building through any driveway, alleyway or parking lot shall also display the same numbers on the rear of the building. (6) Section 4113, Definitions, is added to read as follows' A® "Approved" means approved by the Building Official as meeting the requirements of this Chapter with regard to a given material, mode of construction, piece of equipment or device. B® "Auxiliary Locking Device" is a secondary locking system added to the primary locking system to provide additional security. C, "Bolt" is a metal bar which, when actuated, is projected (or thrown) either horizontally or vertically into a retaining member, such as a strike plate, to pr'event a door from moving or opening. 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26: 27 Ordfnance No. 995 Page t~enty three D® "Part" as dtstfngutshed from component, ts a untt for subassembly, whtch combfnes with other untts to make up a component. E. "Primary Locktng Devfce" ts the sfngle locktng system on a door or wtndow untt whose functton f s to prevent unauthorized tntrusfon. F. "Sfngle Cyllnder Deadbolt" fs a deadbolt lock whfch fs activated from the extertor by a key and from the fnterfor by a knob, thumb-turn, lever or stmtlar mechanism. Ge "Solld Core Door" means a door composed of soltd wood construction. H® "Stile" Is a verttcle framfng member of a wfndow or door. A meettng sttle ts one which mates wtth a stfle of another sash or a verttcal framtng member of a door or wtndow frame when the sash fs fn the closed position. "Strike" ts a metal plate attached to or mortised fnto a door jamb to recefve and to hold a projected latch bolt and/or deadbolt fn order to secure the door to the jamb. "Swinging Door" means a door htnged at the sttle or at the head and threshold. K® "U.L. Listed" means tested and 11sted by Underwrfters' Laboratories, Inc. . Sectton 4114, Keytng Requirements, ts added to Chapter 41 to read as follows- Upon occupancy by the owner or proprietor, each stngle untt tn a tract or commercial development, constructed under the same general plan, shall have locks using combinations whtch are Interchange free from locks used Jn all other separate dwe111ngs, proprietorships or slmtlar dtsttnct occupancies. Thts ts tntended to prohtbtt master keytng. I. _Chapter 51 of the Appendix' Sectton 5110; Permits-Certificate of _~nspectton, is amended to read as follows. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page twenty four a. Permits Required. It shall be unlawful to hereafter install any new elevator, moving walk, escalator, or dumbwaiter, to make major alterations to any existing .elevator, dumbwaiter, escalator or moving walk without having first obtained a permit for such installation from the State of California Division of Industrial Safety. Permits shall not be required for maintenance or minor alterations. (See: ANSI Code, Part XII). b. Certificates of Inspection Required. It shall be unlawful to operate any elevator, dumbwaiter, escalator or moving walk without a current certificate of inspection issued by the State of California Department of Industrial Safety. Such certificate shall be issued annually upon payment of prescribed fees and the presentation of a valid inspection report indicating the the conveyance is safe and that the inspection was made within the previous six (6) months. Certificates shall not be issued when. the conveyance is posted as unsafe pursuant to Section 5114. EXCEPTION: Certificates of inspection shall not be required for..conveyances within a dwelling unit. c. Application for Permits. Appli'cation for a permit to install shall be made on forms provided by the State of California Division of Industrial Safety and the permit · shall be issued to an owner upon payment of prescribed permit fees. d. Application for Certificates of Inspection. Application for a certificate of inspection shall be made by the owner of an elevator, dumbwaiter, escalator or moving walk. Applications shall be accompanied by an inspection report as described in Section 5113. J. Chapter 51 of the Appendix, Section 5113, Requirements for Opera ti on and Maintenance is amended by amending Section ~13(b) and' (e)lto'read as ~ollows:. (b) Annual Inspections and Tests. Except in dwelling units, elevators., escalators and moving walks shall be inspected at least once every twelve (12) months by an inspector for the State of California Division of Industrial Safety. Such inspections shall include tests of the car and counterweight safeties, governors and oil buffers to be made in accordance with Rule 1001.1b of the ANSI Code. 1 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 ~0 25 27 Ordinance No. 995 Page twenty five Inspections and tests shall be made as requtred by Part X of the ANSI Code. (e) Inspection Reports. After each required inspection, a full and correct report of such inspection shall be filed with the State of California Division of Industrial Safety. K. Chapter 51 of the Appendix, Section 5114, Unsafe Conditions, is amended to read as follows: When an inspection reveals an .unsafe condition, the inspector for the State of California Division of Industrial Safety shall immediately file with the owner and the Building Official a full and true report of such inspection and such unsafe condition. If the inspector 'for the State of California Division of Industrial Safety finds that the unsafe condition endangers human life, he shall cause to be placed on such elevator, escalator or moving walk in a conspicuous place, a notice stating that such conveyance is unsafe. The owner shall see to it that such notice of unsafe condition is legibly maintained where placed by the inspector. The State Inspector shall also issue an order in writing to the owner requiring the repairs or alterations to be made to such conveyance which are necessary to render it safe and may order the operation thereof discontinued until the repairs or alterations are made or unsafe conditions are removed. A posted notice of unsafe conditions shall be removed only by the State Inspector when he is satisfied that the unsafe conditions have been corrected. 8105 ADOPTION OF STATE HISTORICAL BUILDING CODE The State of California, California Administrative Code, Title 24, State Building Standards, Part 8, State Historical Building Code, for the purpose of providing alternative building regulations for the rehabilitation, preservation, restoration or relocation of buildings or structures designated as historical buildings by Federal, State of California, County of Orange, or City of Tustin, all provisions in effect October 20, 1979, adopted and published by Office of Administrative Hearings, Department of General Services, distributed by State of California, Documents Section, P.O. Box 1015, North Highlands, California, 95660, one copy of the code has been deposited in the office of the City Clerk, and shall be at all times maintained by the City Clerk for use and examination by the public. Section 2: Chapter two of Article 8 of the City of Tustin is amended to read as follows: 28/ 1 2 3 4 5 6 7 8 9 10 11 12 '13 14: 15 16 17 18 19 20 21 22 23 2,~ 25 26 27 28 Ordlnance No. 995 Page t~enty st x CHAPTER 2 MECHANICAL CODE 8200 ADOPTION OF 1985 UNIFORM HECHANICAL CODE Except as provided in this chapter, that certain Mechanical Code known and designated as the Uniform Mechanical Code, 1985 Edition, published by the International Conference of Building Officials and the International Association of Plumbing and Mechanical Officials, shall be and become the Mechanical Code of the City, regulating and controlling the design, construction, installation, quality of materials, location, operation and maintenance of heating, ventilating, cooling, refrigeration systems, incinerators and other miscellaneous heat producing appliances. One copy-of the Uniform Mechanical Code has been deposited in the office of the City Clerk and shall be at all times maintained by the City Clerk for use and examination by the public. 8201 AMENDMENTS TO THE UNIFORM MECHANICAL CODE The 1985 Uniform Mechanical Code is hereby amended as follows: Part I: Part I is deleted from the Uniform Mechanical Code. 31 Section 3: Chapter 3 of Article 8 of the Tustin City Code is amended to read as follows: CHAPTER 3 PLUMBING CODE 8300 ADOPTION OF 1985 UNIFORH PLUMBING CODE Except as provided in this chapter, that certain plumbing code known and designated as the Uniform Plumbing Code, 1985 Edition, including the appendix to the Uniform Plumbing Code, published by the International Association of Plumbing and Mechanical Officials, shall be and become the Plumbing Code of the City, regulating erection, installation, alteration, repair, relocation, replacement, maintenance or use of plumbing systems within the City. One copy of the Uniform Plumbing Code has been deposited in the office of the City Clerk and shall be at all times maintained by the City Clerk for use and examination by the public. 8301 AMENDMENTS TO THE UNIFORM PLUMBING CODE The 1985 Uniform Plumbing Code is hereby amended as follows: (A) Part I. Part I is deleted from the Uniform Plumbing Code. 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page t~enty seven (B) Sectton 315 ts amended by adding a new subsectfon (g) to read as follows: (G) All earth within the City of Tusttn is corrosive, unless the permittee proves to the satisfaction of the Building Official the specific earth is not corrosive to the plumbing, piping, fittings, fixtures and/or equipment for installation to contact with or buried in the ground. Steel or galvanized steel shall be protected by at least double spiral wrapping, half overlapping with 10 mil plastic tape (total 40 mils cover) or approved equal. (C) Section 1004(a) Amended - Water Distribution Materials Section 1004 of the Uniform Plumbing Code is amended to read as fol 1 ows: Section 1004(a) Materials a) Water pipe and fittings shall be of brass, copper, cast iron galvanized malleable iron, galvanized wrought iron, galvanized steel or other approved materials. CPVC, PB, PE, or PVC water pipe manufactured to recognized standards may be used for cold water distribution systems outside a building. All materials used in the water supply .system, except valves and similar devices shall be of a like material, except where otherwise approved by the Admi nt strati ye Authori ry. 8302 - ADOPTION OF 1985 UNIFORN SOLAR ENERGY CODE For the purpose of prescribing regulations for the erection, construction, enlargement, alteration, repair, moving, removal, conversion, demolition, occupancy, equipment, use, height and area of building structures, all of the provisions of the 1985 Edition of the Uniform Solar Energy Code including the appendix thereto, adopted and published by the International Association of Plumbing and Mechanical Officials. One copy of the code has been deposited in the office of the City Clerk, and shall be at all times maintained by the City Clerk for use and examination by the people. 8303 AMENOINENTS TO THE UNIFOR)I SOLAR ENERGY CODE The 1985 Uniform Solar Energy Code is hereby amended as follows: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26 27 28 Ordinance No. 995 Page twenty et ght (A) Part I. Part I is deleted from the Uniform Solar Energy Code. (B) Section 305 is amended by adding a new subsection (g) to read as mm i ii ii follows: g) All earth within the City of Tusttn is corrosive, unless the permitee proves to the satisfaction of the Building Official the specific earth is not corrosive to the plumbing, piping, fittings, fixtures and/or equipment for installation in contact with or buried in the ground. Steel or galvanized steel shall be protected by at least double, spiral wrapping, half overlapping with 10 mil plastic tape (total 40 mils cover) or approved equal. 34 Section 4: Chapter 4. of Article 8 of the Tusttn City Code is amended to read as follows: CHAPTER 4 ELECTRICAL CODE 8400 ADOPTION OF 1987 NATIONAL ELECTRIC CODE Except as provided in this chapter, that certain electrical code known and designated as the National Electrical Code, 1987 Edition, published by the National Fire Protection Association, shall be and become the Electrical Code of the City, regulating all installation, arrangement, alteration, repair, use and other operation of electrical wiring, connections, fixtures and other electrical appliances on premises within the City. One copy of the National Electrical Code has been deposited in the office of the City Clerk, and shall be at all times maintained by the City Clerk for use and examination by the public. 8401 AMENDMENTS TO THE NATIONAL ELECTRICAL CODE The 1987 edition of the National Electrical Code is hereby amended as follows: Ae Article 90 is hereby amended by the addition of the following sections to read: Article 90-9 Relocated Buildings .... and Structures. Except for Class B-l, B-3 and M-1 occupancies, relocated buildings and structures shall conform to the requirements of this code as if it were a new building or structure. 1 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 ~0 21 23 25 26 27 ':28 Ordinance No. 995 Page twenty nine Article 90-10 Revocations and Suspensions. The Building Official may suspend or revoke any electrical permit for any of the following reasons: . If any reason is found to exist which would have been cause for denial of such permit. 2. Any material mt srepresenta~ion or falsity in the application upon which said permit was issued. . For failure to comply with the provisions of the sections in this code pertaining to electricity; after due notice of corrections and the ti me limit therefore has expired, or for failure to comply with other codes of this jurisdiction that may be related to or appertain to the sections in this Code pertaining to electricity. Article 90-11 Inspections and Corrections. Upon completion of the work which has been authorized by issuance of any permit, except an annual permit, it shall be the duty of the person, firm, or corporation installing the same, to notify the Building Official who shall inspect them installation as soon thereafter as practicable. If, upon inspection, the installation is not found to be in conformity with the provisions of this Code, the Building Official shall notify the person, firm or corporation making the installation, stating the defects which have been found to exist. All defects shall be corrected within ten (10) days after inspection and notification, or within other reasonable time as permitted by the Building Official. No electrical installation shall be energized until inspected and approved by the Bull ding Official. Article 90-12 Approval Of Equipment. All appliances and equipment shall be-listed and labeled by a nationally recognized testing laboratory, equal to but not limited to Underwriters's Laboratories, Inc., and approved by the Building Official. Article 90-13. Used Materials. Previously used materials shall not be re-used without the written approval obtained in advance from the Building Official. Article 90-14 Nameplates. The maker's nameplate, trademark, or other identification symbol shall be placed on the outside, where it is visible at time of inspection on all electrical materials, devices, appliances, fittings, and equipment used or installed under the provisions of this Code. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 22 23 24 25 26 27 28 Ordinance No. 995 Page thirty Artlcle 110-5 ts amended by addlng a second paragraph to read as follows: ....... Conductors shall be of copper. Copper wtre shall be the preferred material used for wtrtng No. 6 and smaller tn all tnstallatlon. Consideration for use of alumlnum wtrtng can be made by the Building Official on an individual case basis where adequate safety measures can be ensured. Article 210-1 is amended by adding the following two paragraphs to read: (a) Accessory uses or other buildings, signs, etc., separately located on the same lot or premises, shall have connecting conductors run underground. (b) Where spare circuit protective devices are provided or space for future circuit protective devices are provided on the bus in any flush or semtflush mounted panel, then raceways of sufficient capacity to permit utilization of such spaces or spaces shall be provided to an approved accessible location. Such accessible locati, on is defined as follows: Where sufficient attic space is available or under floor space is available, a raceway shall terminate conveniently for future use in each such space. Where this condition does not exist, then such terminations shall be approved by the Building Official. (c) Class R-l, R-3 and M-1 occupancies are exempt from the requirements of the above two subsections, 210-1(a) and (b). Article 230-43 is hereby amended by deleting the section and substituting the following to read: Except for Class R-l, R-3 and M-1 occupancies, wiring methods for 600 volts or less. Service-entrance conductors extending along the exterior or entering buildings or other structures, shall be enclosed in rigid, conduit; or, for circuits not exceeding 600 volts, in wireways, auxiliary gutter, or as busways. Article 250-91(a) is hereby amended by deleting the section and substituting the following to read: 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Ordinance No. 995 Page th+try one (a) Grounding Electrode Conductor. The grounding electrode conductor shall be of copper. The material selected shall be resistant to any corrosive condition existing at the installation, or shall be suitably protected against corrosion. The conductor shall be solid or stranded, insulated, covered or bare, and shall be installed in one continuous length without a splice or joint. Article 300-6(b) is amended by adding the following paragraph: All earth within the City of Tustin is corrosive, unless the permtttee proves to the satisfaction of the Building Official the specific earth is not corrosive for the installation of the above noted electrical items in contact with or buried in the earth. Unless otherwise authorized by the Building Official, all such items embedded in the ground shall be protected by at least double, spiral wrapping, half overlapping with 10 mil plastic tape (total 40 mils cover), or approved equal. 8402 UNDERGROUND UTILITIES (a) Whenever any property in any zone is developed with new or relocated buildings or structures, or whenever enclosed floor area in excess of 200 square feet is added to an existing building site in any zone, except zones permitted for single family residential use, or whenever a residential building or use is converted to any purpose or use other than that which existed at the time of conversion, all electrical, telephone, community antenna, television and similar service wires or cables which provide direct service to the property being developed, shall, within the exterior boundary lines of such property, be installed underground. I (b) For the purpose of this Section, appurtenances and associated 20 equipment such as, but not limited to, surface mounted transformers, pedestal mounted terminal boxes and meter cabinets, may be placed above 211 ground. 23 24 25 26 27 28 (c) The developer or owner is responsible for complying with the requirements of this Section, and shall provide all necessary facilities on their premises so as to receive such services from the supplying utility or utilities subject to the applicable rules, regulations and tariffs of the respective utility or utilities on file with the California Public Uti I i ti es Commi ssi on. 1 2 3 5 6 7 8 9 10 11 12 14 15 16 17 18 19 21 22 23 2~ 26 27 Ordinance No. 995 Page thtrty t~o (d) Where practical difficulties or unnecessary hardships Inconsistent with the provisions of thts chapter result from 1ts literal Interpretation or enforcement, the Planntng Commission may watve, modtfy, or delay the application of any undergroundtng requirement upon written request by a butldtng stte owner. Such request shall be ftled wtth the Planning Commission and shall contain any and all facts which are offered I n support. (e) If the Planning Commission's action is to delay the installation of required undergrounding utilities, it may require the building site owner to file with the City a cash deposit, and/or record a covenant sufficient to p.rovide for the future installation of the underground features which are to bedelayed. The amount of the cash deposit shall be determined by the Building Official. 8500 ADOPTION OF THE 1985 UNIFORM SWINI~ING POOL, SPA AND HOT TUB CODE Except as provided in this chapter, that certain Swimming Pool Code known and designated as the Uniform Swimming Pool, Spa and Hot Tub Code, 1985 Edition, published by the International Association of Plumbing and Mechanical Officials, shall be and become the Swimming Pool Code of the City, regulating erection, installation, alteration, repair, replacement, maintenance or use of swimming pools, spas and hot tubs within the City. One copy of the Uniform Swimming Pool, Spa and Hot Tub Code has been deposited in the office of the City Clerk and shall be at all times maintained by the Clerk for use and examination by the public. 8501 NNENDINENTS TO THE UNIFORM SWIllING POOL, SPAS AND HOT TUB CODE The current edition of the Uniform Swimming Pool, Spa and Hot Tub Code is hereby amended as follows: A) Deleting Part 1 with the exception of Sections: 1.0, 1.1, 1.2, 1.3 1.4, 1.8, 1.9, 1.12 and 1.14. B) Section 1.11 is amended to read as follows: Permit Fees. The fees for swimming pools, spa and hot tubs shall be those which the City Council may from time to time adopt by resolution. C) Section 310 Waste Water Disposal. No direct or indirect connection shall be made between any storm drain, sewer, drainage system, seepage pit, underground leaching pit, or subsoil drainage line, and 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page thtrty three any line connected to a swimming pool, unless approved by the Building Official. Waste water from any filter, scum filter, scum gutter, overflow, pool enq~tying line or similar apparatus or appurtenance shall discharge into an approved type receptor and subsequently into a public sewer. The flood level rim of such receptor shall be at least six (6) inches above the flood level of the adjacent ground. Each such receptor, when permitted to be connected to any part of a drainage system shall be provided with an approved three (3) inch trap. Plans and specifications for any deviation from the above manner of installation, shall first be approved by the Building Official before any portion of any such system is installed. Section 320 - The following section is hereby added to the Uniform Swimming Pool Code to read as follows: 1. Every swimming pool, hot tub/spa or other out-of-doors body of water, having a depth in excess of etthteen (18) inches, shall maintain in good condition an enclosure or fence .not less than five (5) feet in height above the adjacent exterior grade. Such fence or wall shall be constructed and maintained with no opening nor projections which could serve as a means to scale same. Vertical openings shall be no wider than four (4) inches, and horizontal members accessible from the exterior, shall be sufficient distance from any structure, shrubbery or grade so as to restrict scaling. 2. All enclosures and gates shall extend to within two (2) inches of firm soil or within four (4) inches of pavement. 3. Gates and door. s opening through such enclosures shall be self-closing and self-latching with release at least four (4) feet above exterior grade, or so located on the pool side as to prevent release from the exterior. Access through the gate or door from outside the pool enclosure shall be by key only. 4. Access from a public street to the front door of any single-family dwelling unit shall not be obstructed by a pool enclosure. 5. Except for single-family residences, the fence or walls shall be so located so there will be no access from any dwelling unit into 1 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 23 ~25 26 Ordinance No. 995 Page thirty four £) the pool enclosure. The fence or walls shall serve to isolate the pool from other activities or structures, and shall be located within fifty (50) feet of the pool. Gates or doors into such enclosures shall be located in view of the pool. A building wall with no doors may be u'sed as part of such pool enclosure when within the specified distance of the pool. EXCEPTIONS: When approved by the Director of Community Development, such enclosures may include sunshade, toilet or shower structures which are used only in conjunction with the pool. Access through an accessory recreation building may be permitted through a lockable door with. a sign above door, one-inch letters with contrasting background, "Lock Door When Pool Is Not In Use." Any lights used to illuminate any swimming pool enclosure shall be so arranged and shaded as to reflect light away from any adjoining premises. Section 321 Construction Requirements is added to read as follows: (1) All pool construction shall be in conformance with engineered design for expansive soils, unless a soils report by a registered engineer approved by the Building Official indicates otherwise. (2) The 'pool shall be constructed not less than seven (7) feet from the top of a cut, fill or natural earth slope, less than five (5) feet from toe of a cut, fill or natural earth slope not less than five (5) feet from the property line (measured from water line). (3) A swimming pool constructed of reinforced concrete or pneumatically placed concrete is not described as an exception in Uniform Administrative Code Section 305(a). A continuous inspection by a special inspector shall be required on all pools constructed of reinforced guntte, or reinforced cast in place concrete. Said special inspector shall insure all electrical bonding is properly installed; ensure all required reinforcing steel and diving board or slide anchor bolts are properly in place, ensure concrete is cast to the thickness required for expansive soil, ensure the concrete is properly placed; and take test samples during the placing of concrete and such samples shall be tested by an approved testing laboratory to attain a strength exceeding two thousand (2,000) psi, or as required by the design engineer at twenty-eight (28) days. Should such test show the concrete to fail or to be of questionable quality or 1 2 3 4 5 6 7 8 9 10' 11 12 13 14 15 16 17 18 i9 20 21 22 23 24 :25 26 27 :28 I Ordinance No. 995 Page thirty five · strength, the special inspector may require core tests to be taken upon approval of the Building Official. Special inspectors shall submit to the Building Official a written report showing the dates of inspection, and the result of the laboratory tests. This report shall indicate the reinforcing steel is per the approved drawings and per Chapter 26, UBC, expansive soil details were followed, the work complies with the approved drawings, this Code and footings and anchor bolts of diving boards and other pool accessories are adequate. F)' Section 322 - Clean-Up Bond is added. The Building Official shall prior to issuing.... a permit for a swimming pool require clean-up bonds as follows: (1) Each applicant for a swimming pool permit shall provide, before issuance, an agreement and cash bond for the purpose of insuring a) that all sand, cement, dirt and any other debris is ren~ved from streets, gutters, curbs, parkways, sidewalks and other public property, b) that the public property shall be left clean and undamaged condition, and c) that adequate barricades have been installed and maintained. Said bond shall be in the amount of fifteen hundred dollars {$1500.00) for the construction of a swimming pool or other construction related thereto requiring the use of heavy equipment. (2) Said agreenmnt and bond may be reduced to not less than five hundred dollars ($500.00) for the issuance of a spa, jacuzzi, and other small pool permit not intended for swimming, when in the · determination of the Building Official the scope of the project will have a minimal impact on public improvements; by reason of not requiring the use of heavy construction equipment over curbs, si.dewalks or public streets. (3) Said bond shall terminate and be returnable to the applicant at the time and provided that a) debris and other materials have been properly removed, b) the public property has been left clean and undamaged. All damage to public curbs, gutters, sidewalks, driveways and light standards during the construction of pool, shall be repaired prior to preplaster inspection. A written, signed release from the City Engineer shall be filed with the Building Official to ensure damages have been repaired. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25- 26 27 28 Ordinance No. 995 Page thtrty stx A letter stattng that excess dtrt, debris, trash and other materials from the pool construction have been disposed of at the Orange County dtsposal statton or other authorized location, must be delivered to the Butldtng Offtctal by the permtttee prtor to preplaster Inspection. (4) If the public property has not been left in a clean and undamaged condition and/or adequate barricades required by the City Engineer have not been installed and maintained, the City shall cause the necessary work to be done and shall deduct the cost thereof from the bond. G) Section 323 Public Encroachment Materials on Public Property. The Building Official shall advise at permit issuance, and he shall enforce the requirement of this Section by stop order if necessary, the following: Construction materials, debris, trash containers (~sters), and other non-vehicle materials shall not be deposited on public property without the written approval of the Ct..ty Engineer and only under such conditions as he may impose. Any barricading required by the City Engineer shall be provided by the contractor at his expe.nse. H) Section 324 Modification of Requirements, is added to read as follows: (1) Following written request by the owner, the Building Official may modify or eliminate the requirements of this Code where, in the judgment of the Building Official, UAC Section 108, such request is justified and will not result in unsafe conditions. The Building Official may require that evidence or proof in the form of affidavits, recorded easements or other documents be submitted to substantiate or justify such requests and may apply reasonable conditions to ensure ultimate compliance with the spirit of this Section in the event of a change of conditions. (2) The pump/filter may be loca'ted in the side yard setback provided it is within one (1) foot of the dwelling exterior wall and four (4) feet from the property line and at least ten (10) feet away from an existing or possible future adjacent on-site or off-site dwelling window and/or covered patio. This provision is to attenuate noise to a reasonable level. (3) The gas fuel fired water heater may be located within the side yard setback, provided it is located.within one (1) foot of the exterior wall of the dwelling, four (4) feet from the property line, four (4) feet from a window or door, ten (10) feet from'an HVAC air intake, window, greenhouse or patio (on or off-site) and 1 3 4 5 6 7 8 9 10 1-! 12 13 14 15 16 17 18 19 20 23 25 27 Ordinance No. 995 Page thirty seven ten (10) feet from off-site sensitive (to products of combustion) plants. The heater shall be installed with clearance as listed by the American Gas Association or Underwrtter's Laboratories. Section 6: Chapter 6 of Article 8 of the Tusttn City Code is amended to iii read as follows: CHAPTER 6 8600 ADOPTION OF 1985 UNIFORM SIGN CODE For the purpose of prescribing regulations for the erection, construction, enlargement, alteration, repair, moving, removal, conversion, demolition, occupancy, equipment, use, height and area of building structures, all of the provisions of the 1976 edition of the Uniform Sign Code including the appendix thereto, adopted and published by the International Conference of Building Officials. One copy of the Uniform Sign Code has been deposited in the office of the City Clerk and .shall be at all times maintained by the City Clerk for use and examination by the public. 8601 CONFLICTS WIlll ARTICLE 9400, SIGNING CODE · , Nothing in this Article 8600 shall be construed to be in' conflict with Article 9400, Signing Code, Tustin City Code and guidelines and standards ... "regarding"... "the character of signs and sign structure ..." The purpose of Article 8600; Sign Code, Tustin City Code," .... is to provide minimum standards to safeguard life, health, property and public welfare by regulating and controlling the design, quality of materials, construction, location, electrification and maintenance of all signs and sign structures not within a building." Any conflicts between Article 9400 and Article 8, Building Regulations, Tustin City Code, regarding enforcement of adopted codes and amendments, the provisions and requirements of Article 8 shall govern. Section 6: Chapter 7 of Article 8 of the Tustin City code is amended to read as follows: CHAPTER 7 8700 UNIFORM HOUSING CODE ADOPTED Except as provided in this chapter, that certain housing code known and designated as the Uniform Housing Code, 1985 Edition, published by the International Conference of Building Officials, shall become the Housing Code of the City, regulating and controlling the use and occupancy, 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 ,23 2t 25 26 27 :28 Ordinance t. lo. 995 Page thtrty eight location and maintenance of all residential buildings and structures within this City. One copy of the Uniform Housing Code has been deposited in the office of the City Clerk and shall be at all times maintained by the City Clerk for use and examination by the public. Sectton 8 of Arttcle 8 of the Tusttn City Code ts amended to read as follows: CHAPTER 8 8800 ADOPTION OF 1985 UNIFORM CODE FOR THE ABATEMENT OF DANGEROUS BUILDINGS Except as otherwise provided in this Chapter, that certain but]ding code known and designated as the Uniform Code for the Abatement of Dangerous Buildings, 1985 Edition, pub]tshed by the International Conference of Building Officials, shall be and become the Code of the City for the Abatement of Dangerous But]dings; providing for a just, equitable and practica] method, to be cumulative with and in addition to, any other remedies provided by the Building Code, Housing Code, or otherwise aval]ab]e at ]aw, whereby butldlngs or structures which from any cause endanger the life, limb, health, morals, property, safety or welfare of the general public or their occupants, may be requested to be repaired, vacated or demolished. One copy of the Uniform Code for the Abatement of Dangerous But]dings has been deposited in the office of the City Clerk, and shall be at al] times maintained by the City C]erk for use and examination by the public. 8801 AMENDMENTS TO THE UNIFORM CODE FOR THE ABATEMENT OF DANGEROUS BUILDINGS The 1985 Edttton of the Untform Code for the Abatement of Dangerous Buildings ts amended as fol]ows: (a) Sectton 801(a). Subsection (a) of Sectton 801 is amended to read as follows: (a) Procedure. When any work of repair or demolition is to be done pursuant to Sectton 701(c)3 of thts code, the Building Offtcia] sha]] cause the work to be accomp]tshed by Ctty personnel or by prtvate contract under the direction of the Bui]dtng Offtcta]. Plans and specifications therefore may be prepared by the Butldtng Offlcia], or he may emp]oy such architectural and/or engineering assistance on a contract basis as he may deem reasonab]y necessary. If any part of the work is to be accomp]ished by private contract, standard pub]lc works contractural procedures sha]] be roi]owed. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Ordinance No. 995 Page thtrty ntne (b) Sectton 802(a). Subsectfon (a) of Sectfon 802 ts amended to read is' ~ollows: (a) General. The legislative body of this jurisdiction shall establish a special revolving fund to be designated as the repair and demolition fund. Payments shall be made out of said fund upon the demand of the Building Official to defray the costs and expenses which may be incurred by this jurisdiction in doing or causing to be done the necessary work of repair or demolition of dangerous buildings. (c) Section 901 Section 901 is amended to read as follows: The Building Official shall keep an itemized account of the expense incurred by this jurisdiction in the repair or demolition of any building done pursuant to the provisions of Section 701(c)3 of this Code. Upon the completion of the work of repair or demolition, said Building Official shall prepare and file with the clerk of this jurisdiction a report specifying the work done, the itemized and total cost 'of the work, a description of the real property upon which the building or structure ts or was located, and the names and addresses of the person, s entitled to notice pursuant to Subsection (c) of Section 401. (d) Section 902 Section 902 of is amended to read as follows: Upon receipt of said report, the clerk of this jurisdiction shall present it to the legislative body of this jurisdiction for consideration. The legislative body of this jurisdiction shal.1 fix a time, date and place for hearing said report, and any protests or objections thereto. The clerk of this jurisdiction shall cause notice of said hearing to be posted upon the property involved, published once in a newspaper of general circulation in the City, and served by certified mail, postage prepaid, addressed to the owner of the property as his name and address appear on the last equalized assesment roll of the County, if such so appear, or as known to the Clerk. Such notice shall be given at least ten (10) days prior to the date set for hearing and shall specify the day, hour, and place when the legislative body will hear and pass upon the Building Official's report, together with any objections or protests which may .be filed as hereinafter provided by any person interested in or affected by the proposed change. 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 Ordinance No. 995 Page fourty (e) Section 903 is amended to read as follows: Any person interested in or affected by the proposed charge may file written protests or objections with the clerk of this jurisdiction at any time prior to the time set for the hearing on the report of the Building Official. Each such protest or objection must contain a description of the property in Which the signer thereof is interested, and the grounds of such protest or objection. The clerk of this jurisdiction shall endorse on every such protest or objection the date it was received by him. He shall present such protest or objection to the legislative body of this jurisdiction at the time set for the hearing, and no other protests or objections shall be considered. (f) Section 904 is amended to read as follows: Upon the day and hour fixed for the hearing of the legislative body of this jurisdiction shall hear and pass upon' the report of the Building Official together with any such objections or protests. The legislative body may make such revision, correction or modification in the report or the charge as it may deem just, and when the legislative body is satisfied with the correctness of the charge, the report (as . submitted or as revised, corrected or modified) together with the charge, shall be confirmed or rejected. The decision of the legislative body of this jurisdiction on the report and the charge, and on all protests or objections, shall be final and conclusive. Section g: SEVERABILITY OF PARTS OF THIS ORDINANCE AND THE ADOPTED CODES · It is hereby declared to be the intention of the City Council that the sections, paragraphs, sentences, clauses and phrases of this Ordinance and the adopted Codes are severable, and if any phrase, clause, sentence, paragraph or section of this Code shall be declared unconstitutional by the valid judgment or decree of court of competent jurisdiction, such unconstitutionally shall not affect any of the remaining phrases, clauses, sentences, paragraphs and sections of this Ordinance and the adopted Codes. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26 27 28 Ordtnanc~ No.. 995 Page fourty one The City Clerk shall certify to the passage and adoption of this Ordinance by the City Council of the City of Tustin and shall, within fifteen (15) days after its final passage, cause the same to be published once in the Tustin News, a newspaper of general circulation which is hereby designated for that purpose and this ordinance shall take effect thirty (30) days after its passage. PASSED AND ADOPTED at a regular meeting of the City Council of the City of Tustin, held on the day of , 198 . RICHARD B. EDGAR, Mayor MARY E. WYNN City Clerk 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 RESOLUTION NO. 87-133 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF TUSTIN, SETTING FORTH FINDINGS WITH RESPECT TO LOCAL CONDITIONS WITHIN THE CITY OF TUSTIN WHICH MAKE CERTAIN MODIFICATIONS AND CHANGES TO THE UNIFORM BUILDING CODE, THE UNIFORM PLUMBING CODE, AND THE NATIONAL ELECTRICAL CODE REASONABLY NECESSARY FOR HOUSING OCCUPANCIES WHEREAS, Health and Safety Code Section 17958 provides that the City of Tustin ("City") shall adopt Ordinances and regulations imposing the same or modified or changed requirements as are con- tained in the regulations adopted by the State pursuant to Health and Safety Code Section 17922; and WHEREAS, the State of California is mandated by Health and Safety Code Section 17922 to impose the same requirements as are contained in the most recent edition of the Uniform Housing Code of the International Conference of Building Officials, the Uniform Plumbing Code of the International Association of Plumbing and Mechanical Officials, the Uniform Mechanical Code of the Inter- national Conference of Building Officials, the International Asso- ciation of Plumbing and Mechanical Officials, and the National Electrical Code of the National Fire Protection Association (here- inafter referred to collectively as "Codes"; and WHEREAS, Health and Safety Code Section 17958.5 authorizes the City to make such changes or modifications to the Codes as the City determines are reasonably necessary because of local climatic, geological or topographical conditions; and WHEREAS, Health and Safety Code Section 17958.7 requires that the City Council, before making any modifications or changes to the Codes, shall make an express finding that such changes or modifications are reasonably necessary because of local climatic, geographic or topographic conditions; and WHEREAS, the Building Official and Director of Community Development have recommended that changes and modifications be made to the Codes and have advised that certain said changes and modifi- cations to the Uniform Building Code, 1985 Edition and the Uniform Plumbing Code, 1985 Edition and National Electrical Code, 1987 Edition, are reasonably necessary due to local conditions in the City of Tustin and have further advised that the remainder of said changes and modifications are of an administrative or procedural nature, or concern themselves with subjects not covered by the Codes or are reasonably necessary to safeguard life and property within the City of Tustin. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Tustin as follows: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Section 1 The following changes and modifications to the 1985 Edition of the Uniform Building Code as recommended by the Building Official and Director of Community Development are hereby found to be reasonably necessary due to the following local condi- tions for housing. A, Section 3202 (B) has been amended to prohibit the use of untreated non-fire retardant wood materials for roofing due to: I · Prevailing 'Santa Ana' high winds occurring in the local region during a substantial part of the year which contribute to fire spread. · Untreated wood roofs, cause or contribute to the serious fire hazard and to the rapid spread of fires when such fires are accompanied by high winds. Pieces of burning wooden roofs become flying brands and are carried by the wind to other locations and thereby spread fire rapidly. Section 2 The following changes and modifications to the 1985 Edition of the Uniform Plumbing Code as recommended by the Building Official and Director of Community Development are hereby found to be reasonably necessary due to the following local condi- tions for housing. A. Section 315 (g) has been added to state that the type of soil prevalent in the City of Tustin is extraordinarily high in sulfur and acid content. That extra precaution and protection is required for the protection of steel piping and fittings buried in the ground. B. Section 1004 has been amended to prohibit the use of lead and asbestos cement materials in all potable water supply systems. C. Article 110-5 of the 1987 Edition of the National Electrical Code is amended by making copper wire the preferred material used for wiring No. 6 and smaller. i · This amendment is considered necessary due to the fact that improper installation creates a potential fire hazard and aluminum wire size No. 6 and smaller re- quires greater precision and care for proper installa- tion. Workmanship problems have been experienced in the local area, which makes this provision necessary. The regulation of aluminum wire is reasonably necessary to safeguard life and property within the City of Tustin. Section 3 Additional amendments have been made to the Uniform Building Code, 1985 Edition, the Uniform Plumbing Code, 1985 Edition, Uniform Mechanical Code, 1985 Edition, and the National Electrical Code, 1987 Edition. On the recommendation of the Building Official and Director of Community Development, such 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 amendments are hereby found to be either administrative or proce- dural in nature or to concern themselves with subjects not covered in the Uniform Building Code, Uniform Plumbing Code or National Electrical Code. The changes made include provisions making each of said Codes compatible with other Codes enforced by the City and fee schedules. Section 4 The City Clerk shall file a copy of this Resolution with the Department of Housing and Community Development of the State of California. PASSED AND ADOPTED by the City Council of the City of Tustin, California, on this day of , 1987~ Mayor ATTEST: (C256) 8/3/87 City Clerk