Loading...
HomeMy WebLinkAbout05 SECOND AMENDMENT TO COMMUNICATIONS SITE LICENSE AGREEMENT WITH NEW CINGULAR WIRELESSDocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 4 AGENDA REPORT MEETING DATE: FEBRUARY 20, 2024 5 Agenda Item DS Reviewed: City Manager DS Finance Director TO: NICOLE BERNARD, ACTING CITY MANAGER FROM: CHAD W. CLANTON, DIRECTOR, PARKS AND RECREATION SUBJECT: SECOND AMENDMENT TO COMMUNICATIONS SITE LICENSE AGREEMENT WITH NEW CINGULAR WIRELESS PCS, LLC (AT&T) FOR EXISTING WIRELESS FACILITIES AT TUSTIN SPORTS PARK (12850 ROBINSON DRIVE) SUMMARY Second Amendment to Communications Site License Agreement between the City of Tustin and New Cingular Wireless PCS, LLC (AT&T). The Amendment would allow New Cingular Wireless PCS, LLC to make additional improvements to an existing communications site as described in Exhibit 3-B of the attachment. RECOMMENDATION It is recommended that the City Council take the following actions: 1. Approve the attached Second Amendment to Communications Site License Agreement with New Cingular Wireless PCS, LLC; and 2. Authorize the Acting City Manager to execute this Second Amendment. FISCAL IMPACT The City entered into a Communications Site License Agreement (License Agreement) with New Cingular Wireless PCS, LLC (Licensee) on February 18, 2014, for one carrier to occupy the Licensee's facilities, with a term of 10 years with two 5-year options. License payments are escalated annually at 4%. The Licensee is currently finishing the loth year of the agreement and paying $58,260 per year ($4,855 per month) for the right to retain existing facilities and antennas at Tustin Sports Park. The Second Amendment to the Communications Site License Agreement will require the Licensee to pay an additional $4,800 per year ($400 per month) for the addition of a standby generator to the site as depicted in Exhibit 3-B of the Attachment. The term of the Second Amendment is coterminous with the current License Agreement of 10 years with two 5-year options, with license payments escalated annually at 4%. Over the remaining two 5-year options extending the term through 2033, the Licensee's gross license payments will total $785,064. The City will receive 80% of the gross payments ($628,051) and the other 20% will go to ATS Communications as the City's consultant for this License Agreement, including any amendments and extension periods. DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 CORRELATION TO THE STRATEGIC PLAN This action advances Goal C of the City of Tustin Strategic Plan regarding Financial Strength by providing opportunities for new/increased revenues. BACKGROUND Wireless facilities have been located in Tustin Sports Park since 1996. The equipment facilities are located behind the scoreboard adjacent to Jamboree Road and the antennas are located on the light standards located adjacent to the ballfields. The licensee has had equipment at this site since 2003 and is presently finishing the initial 10-year term of the current License Agreement and beginning the first of the two 5-year extensions. On February 19, 2019, City Council approved a First Amendment authorizing the Licensee to make additions to their wireless facilities at Tustin Sports Park in exchange for an increase in the license fees. In August 2021, the Licensee contacted the City with a proposal for the installation and operation of a standby generator to provide backup power for their equipment at their wireless facilities at the Tustin Sports Park. Since that time, ATS Communications has been in negotiations (on behalf of the City) with the Licensee to establish the terms of the Second Amendment. Once this Amendment is approved, staff will work with ATS Communications to ensure the Licensee secures the necessary building permits before proceeding with the project. DocuS/Iigne11d11 by: l ,Vu Chad W. Clanton, Director Parks & Recreation Attachment — Second Amendment to Communications Site License Agreement DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 Market: Los Angeles Cell Site ?dumber: LAC939 Cell Site Name: Tustin Sports Part: Fixed Asset (dumber: 10101393 SECOND AMENDMENT TO COMMUNICATIONS SITE LICENSE AGREEMENT This Second Amendment to Communications Site License Agreement ("Amendment"), dated as of the latter of the signature dates below ("Effective Date"), is by and between City of Tustin, a municipal corporation, having a mailing address of300 Centennial Way, Tustin, CA 92780 ("City") and New Cingular Wireless PCS, LLC, a Delaware limited liability company, having a mailing address of 1025 Lenox Park Blvd. NE, 311' Floor, Atlanta. GA 30319 ("Licensee"). WHEREAS, City and Licensee entered into a Communications Site License Agreement dated February 18, 2014, as amended by that certain First Amendment to Communications Site License Agreement dated February 21, 2019, whereby Citv licensed to Licensee certain Premises, therein described, that are a portion of the Property located at 12850 Robinson Drive, Tustin, CA 92782, more commonly known as Tustin Sports Park ("Agreement"), and WHEREAS, Licensee intends to change, modify, or relocate the Licensees Facilities, which City is willing to approve; and WHEREAS, City and Licensee intend to amend the Agreement to clarify scope of Licensee's permitted use of the Premises; and WHEREAS, City and Licensee intend to increase the License Payment in conjunction with the modifications to the Agreement contained herein; and WHEREAS, City and Licensee desire to amend the Agreement to modify the notice section thereof; and WHEREAS, City and Licensee, in their mutual interest, %%ish to amend the Agreement as set forth below accordingly. NOW THEREFORE, in consideration of the foregoing and other good and valuable consideration, the receipt and sufficiency of which are hereby acknowledged. City and Licensee agree as follows: 1. Additional Equipment. In addition to the existing Licensee's Facilities permitted in the Agreement, City consents to the installation and operation of a standby generator and other specified equipment ONLY as shown on attached Exhibit 3-B, the City approved plans for the addition of a generator at Tustin Sports Park. 2. License Payment. Commencing on the first day of the month follow'Ing the Effective Date, the License Payment shall be increased by Four Hundred and No,+100 Dollars (S400.00) per month, subject to further adjustments as provided in the Agreement. DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 Market: Los Angeles Cell Site Number: LAC939 Cell Site Namc: Tustin Sports Park Fixed Asset Number: 10101393 3. Notices. Section 20.9 of the Agreement is hereby deleted in its entirety and replaced with the following: NOTICES. All notices, requests, demands and communications hereunder will be given by first class certified or registered mail, return receipt requested, or by a nationally recognized overnight courier, postage prepaid, to be effective when properly sent and received, refused or returned undelivered. Notices will be addressed to the parties as follows. If to City: City of Tustin Attn: City Manager's office 300 Centennial Way Tustin, CA 92780 With copy to: Tustin City Attorney's Office c/o Woodruff & Smart 555 Anton Boulevard Costa Mesa, CA 92626 ATS Communications 4195 Chino Hills Pkwv, #605 Chino Hills, CA 91709 If to Licensee: New Cingular Wireless PCS. LLC Attn: TAG - LA Re: Cell Site 3i: LAC939 Cell Site Name: Tustin Sports Park Fixed Asset Number: 10101393 1025 Lenox Park Blvd. NE 3rd Floor Atlanta, GA 30319 With copy to. New Cingular Wireless PCS, LLC Attn: Legal Department Re: Cell Site #: LAC939 Cell Site Name: Tustin Sports Park (CA) Fixed Asset Number: 10 10 1393 208 S. Akard Street Dallas, Texas, 752024206 4. Continued Effect. Any capitalized terms used in this Amendment that are not defined herein shall have the meanings given those terms in the Agreement. Unless the context clearly indicates otherwise, all references to the "Agreement" in this Amendment shall hereinafter be deemed to refer to the Agreement_ as amended hereby. Except as specifically modified by this Amendment, all of the terms and conditions of the Agreement shall remain in full force and DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 Alarket: Los Angeles Cell Site Number: LAC939 Cell Site Name: Tustin Sports Park Fixed Asset Number. 10 10 1393 effect. In the event of a conflict between any term or provision of the Agreement and this Amendment, the terms and provisions of this Amendment shall control. All captions are for reference purposes only and shall not be used in the construction or interpretation of this Amendment. 5. Capitalized Terms. All capitalized tenns used but not defined herein shall have the same nreaninus as defined in the Agreement_ IN NVITNESS WHEREOF, the parties have caused this Amendment to be effective as of the last date written below. CITY: City of Tustin, a municipal corporation By: Print Name: Its: Date: LICENSEE: New Cingular Wireless PCS, LLC, a Delaware hinited liability company By: AT&T Mobility Corporation Its: Manager By: JMA �, to tADJ=� Print Name. ,'I t _snc w cl erg Its: a q er Date: / X 010 DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 Market Los Angeles Cell Site Number: LAC939 Cell Site Name: Tustin Sports Park Fixed Asset Number 10101393 ATTACIMI ENT 3-B THE FACILITIES (See attached Drawings) DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO THE START OF CONSTRUCTION. TANGENT DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. NOTE: EVERYTHING SHOWN IS EXISTING UNLESS MARKED NEW EXISTING TREE, TYP. `408 JNE PARCEL #:590-021-08 / / RO FIELD LIGHTS WITH EXISTING AT&T ANTENNAS / / / at&t GENERAL DYNAMICS Information Technology Tangent DRAWN BY: CF CHECKED BY: MR 5 01/19/2023 100% CD'S - CX COMMENTS RM 4 09/20/2022 100% CD'S - CX COMMENTS TJ 07/20/2022 100%CD'S-JX COMMENTS RM 2 O6/08/2022 100% CD'S - CX COMMENTS RM 1 04/07/2022 100% CD'S - ILL COMMENTS OIL 0 02/10/2022 100% CD'S FOR SUBMITTAL SM A 10/15/2021 90%CD'S FOR REVIEW CIF REV DATE DESCRIPTION BY THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION. CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. AT&T SITE NUMBER: 10101393 AT&T SITE NAME: IRVINE / JAMBOREE 12850 ROBINSON DRIVE TUSTIN, CA 92782 GENERATOR INSTALLATION PROJECT SHEET TITLE SITE PLAN SHEET NUMBER A-1 SITE PLAN 24"x36" SCALE: 1" = 30'-0" 0" 15' 30' 60, I A 11"x17" SCALE: 1" = 60'-0" 1 DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 EXISTING CONDITIONS: THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO THE START OF CONSTRUCTION. TANGENT DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. GENSET USE. CEQA & BAAQMD EXEMPTION: THE PROPOSED GENERAC SDO30 GENSET: • IS RATED AT 49 HP AT MAXIMUM RATED KW OUTPUT • IS INSTALLED WITH AN ABOVE -GROUND DOUBLE -WALL SECONDARY CONTAINMENT BASE FUEL TANK WITH 190 USABLE GALLONS OF FUEL. • USES ULTRA LOW SULFUR DIESEL FUEL (15 PPM SULPHUR) • IS LIMITED TO 100 HOURS PER YEAR OF NON -EMERGENCY USE (TESTING & MAINTENANCE). • IS INSTALLED WITH A LEVEL 2 ACOUSTIC ENCLOSURE, WHICH BUFFERS SOUND OUTPUT TO A MAXIMUM OF 62 DB AT 7 METERS (-23 FEET). • IS COMPLIANT WITH APPLICABLE AIR QUALITY REGULATIONS. • IS EXEMPT FROM AIR QUALITY PERMITS IN MOST JURISDICTIONS UNDER THE PROVISIONS OF CLASS 1, SEC. 15301 OF THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA) GUIDELINES. • IS EXEMPT PER BAAQMD REG. 2, RULE 1, SEC. 2-1-114-2.2.1.; LESS THAN 50 BHP. CUMULATIVE VOLUME CALCULATIONS: THE PHYSICAL DIMENSIONS OF THE PROPOSED GENERATOR W/ ENCLOSURE AND BASE FUEL TANK ARE LESS THAN 250 CU. F. IN VOLUME. BASE FUEL TANK = 29"H X 37.4W X 106.6"L = 66.9 CU. FT. GENERATOR BODY W/ ENCLOSURE = 62-H X 38-W X 94.8"L = 129.3 CU. FT. TOTAL CUMULATIVE VOLUME OF GENSET = 66.9 + 129.3 = 196.2 CU. FT. NOTE: EXISTING EQUIPMENT (OTHER CARRIER), TYP.- EVERYTHING SHOWN IS EXISTING UNLESS MARKED PROPOSED I EXISTING EQUIPMENT (OTHER CARRIER), TYP.- EXISTING AT&T UMTS CABINET -SPORTS FIELD �� EXISTING AT&T UMTS CABINET EXISTING EQUIPMENT (OTHER CARRIER), TYP. EXISTING CONCRETE CURB EXISTING SCOREBOARD EXISTING TREE, TYP. PARCEL #:590-021-08 o-� EXISTING. AT&T GSM CABINET II EXISTING AT&T GSM CABINET EXISTING. AT&T DDTV CABINET EXISTING AT&T POWER CABINET �a a EXISTING PAD MOUNTED TRANSFORMER - EXISTING METER CABINET 19, 10, WITH EXISTING AT&T METER NEW AT&T EQUIPMENT AND LBB RECEPTACLE MOUNTED TO EXISTING WALL 1 NEW t5' AT&T UNDERGROUND ELECTRICAL CONDUIT ® INEW GENERAC SD030 30KW DIESEL GENERATOR I n , PER MANUFACTURERS SPECIFICATIONS, GENERATOR e \ , IS 7'-7" HIGH FROM TOP OF SLAB. PER NFPA 0 110 - OPTION REQUIRED STANDBY _ - SEE NEW EQUIPMENT PLAN A115 NEW PRIVACY SCREENING (PHIFERTEX OR EQUIVALENT) TO BE ATTACHED TO (N) WROUGHT IRON FENCE . r NEW AT&T 10'-0" X 16'-0' (160 SQ FT) LEASE AREA EXISTING AT&T POWER PULLBOX SAM so EXISTING FIBER STORAGE BOX EXISTING (2) PURCELL CABINETS STACKED EXISTING AT&T PDU CABINET 1 EXISTING AT&T PDU (CABINET 2 l EXISTING AT&T DC I12 BOX EXISTING IRON FENCE N 151 S at&t GENERAL DYNAMICS Information Technology Tan- ent 2VORBA Ll-, c 92ee)1 DRAWN BY: CF CHECKED BY: MR 5 01/19/2023 100% CD'S - CX COMMENTS RM 4 09/20/2022 100% CD'S - CX COMMENTS TJ 07/20/2022 100%CD'S -JX COMMENTS RM 2 06/08/2022 100% CD'S - CX COMMENTS RM 1 04/07/2022 100% CD'S - ILL COMMENTS OIL 0 02/10/2022 100%CD'S FOR SUBMITTAL SM A I 10/15/2021 90%CD'S FOR REVIEW CIF REV DATE DESCRIPTION BY THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION. CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. AT&T SITE NUMBER: 10101393 AT&T SITE NAME: IRVINE / JAMBOREE 12850 ROBINSON DRIVE TUSTIN, CA 92782 GENERATOR INSTALLATION PROJECT SHEET TITLE NEW ENLARGED SITE PLAN SHEET NUMBER A-2 NEW ENLARGED SITE PLAN 24?36 SCALE: 1/4" = 1'-0" 0" 2' 4' 8' I A 11x17" SCALE: 1/8" = 1'-0" 1 DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO THE START OF CONSTRUCTION. TANGENT DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. UTILITY NOTE THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM RECORD INFORMATION. THE INFORMATION PROVIDED IS IMPLIED NOT INTENDED TO BE A COMPLETE INVENTORY OF THE UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. SCOPE OF WORK DETAIL: GENERAL: • NEW GENERAC DIESEL GENERATOR PROVIDED BY GENERAL DYNAMICS & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS GD-1 AND GD-2. • NEW CONCRETE PAD PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEET S-1. • NEW GENERAC AUTOMATIC TRANSFER SWITCH PROVIDED BY GENERAL DYNAMICS & INSTALLED BY CONTRACTOR. SEE SHEETS E-1, E-3, GD-2. • CONTRACTOR TO VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL RESTORE & REPAIR ANY DAMAGED AREAS CAUSED BY CONSTRUCTION TO ORIGINAL OR BETTER CONDITION. • INNER AND OUTER TANK TESTING DOCUMENTATION SHALL BE PROVIDED ONCE TANK IS IN PLACE ON SITE IN ACCORDANCE WITH NFPA 30. • A CALIBRATION CHART OF PERMANENT AND DURABLE CONSTRUCTION SHALL BE LOCATED AT THE FILL BOX. CONDUITS • INSTALL PULL STRING IN EACH CONDUIT. • (2) NEW ELECTRICAL CONDUITS WITH CONDUCTORS TO BE INSTALLED FROM NEW GENERATOR TO NEW ATS. CONDUIT PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2, E-3, G-1. • (2) NEW ELECTRICAL CONDUITS WITH CONDUCTORS TO BE INSTALLED FROM NEW GENERATOR TO AC PANEL. CONDUIT PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2, E-3, G-1. • (1) NEW ALARM CONDUIT & CABLING PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2, E-3, G-1. GROUNDING: • NEW EXOTHERMIC CONNECTION FROM EXISTING GROUND RING TO NEW MECHANICAL CONNECTION AT GENERATOR CHASSIS. GENERAL CONTRACTOR TO VERIFY LOCATION IN FIELD. LOCATE GROUND RODS NO MORE THAN 8'-0" APART. SEE SHEET E-2, E-3, G-1. H—FRAME: • CONTRACTOR TO PROVIDE NEW H—FRAME FOR ATS INSTALLATION (IF REQUIRED). MATCH EXISTING H—FRAME MATERIAL FOR CONSTRUCTION OF NEW H—FRAME. SEE SHEET E-3. POWER ROUTING KEYED NOTES: M/D EXISTING AT&T METER AND DISCONNECT INTERCEPT EXISTING CONDUIT AND CONDUCTORS AT DISCONNECT AND INT RE—ROUTE THROUGH PROPOSED ATS. COORDINATE PATH WITH CONSTRUCTION MANAGER. q EXISTING AC LOAD CENTER PROPOSED AT&T UNDERGROUND CONDUIT ROUTE. CONTRACTOR TO CON LOCATE EXISTING UTILITIES PRIOR TO EXCAVATION. SEE SHEETS E-1, E-2, E-3, G-1. SEE SHEET E-1 FOR SINGLE LINE DIAGRAM. PROPOSED AT&T 30KW DIESEL GENERATOR W/ SOUND ATTENUATED GEN ENCLOSURE, NORMAL / EMERGENCY TANK VENTING AND BASE FUEL TANK. SEE SHEETS GD-1 AND GD-2. OFUEL FILL SHALL BE PROVIDED WITH SPILL CONTROL, WITH A SOLID FILL CONNECTION, AND WITH OVERFILL PREVENTION. OFUEL TANK NORMAL AND EMERGENCY VENTS SHALL TERMINATE AT LEAST 12'-0" ABOVE THE ADJACENT GRADE. SEE SHEET GD-1. O NFPA 704 PLACARD AND OTHER SIGNAGE. SEE SHEET SG-1. FIRE EXTINGUISHER, (2A-20BC OR APPROVED EQUAL) PER CFC 906.3 FIRE FIRE EXTINGUISHER CABINET (BFC-7009 OR APPROVED EQUAL), MOUNTED TO WALL OR H—FRAME PER CFC 906.9 (5'-0" MAX ABOVE GRADE) OFF LOCKABLE EMERGENCY SHUTOFF SWITCH, MOUNTED TO WALL OR ED H—FRAME PER CFC 906.9 (5'-0- MAX ABOVE GRADE) ATS PROPOSED ATS W/ CAMLOCK MOUNTED TO WALL OR H—FRAME WITH 2D 36" FRONT CLEARANCE. SEE SHEET GD-2. NOTE: 1. EVERYTHING SHOWN IS EXISTING UNLESS MARKED NEW 2. CONTRACTOR TO PROVIDE REQUIRED SIGNAGE FOR ELECTRICAL PANELS, DISCONNECTS, TRANSFER SWITCHES, ETC PER CALIFORNIA ELECTRICAL CODE ARTICLE 702.7 at &t GENERAL DYNAMICS Information Technology Tangent 2VORBA Ll-, c 92ee)I DRAWN BY: CF CHECKED BY: MR 5 01/19/2023 100% CD'S - CX COMMENTS RM 4 09/20/2022 100% CD'S - CX COMMENTS TJ 07/20/2022 100%CD'S -JX COMMENTS RM 2 06/08/2022 100% CD'S - CX COMMENTS RM 1 04/07/2022 100% CD'S - ILL COMMENTS I OIL 0 02/10/2022 100% CD'S FOR SUBMITTAL SM A 10/15/2021 90%CD'S FOR REVIEW CIF REVI DATE I DESCRIPTION BY THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION. CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. AT&T SITE NUMBER: 10101393 AT&T SITE NAME: IRVINE / JAMBOREE 12850 ROBINSON DRIVE TUSTIN, CA 92782 GENERATOR INSTALLATION PROJECT SHEET TITLE EXISTING EQUIPMENT PLAN SHEET NUMBER A-3 NOTES EXISTING EQUIPMENT PLAN 24?36" SCALE: 1/2" = 1'-0" 0" 1' 2' 4 11x17" SCALE: 1/4" = V—O" DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO THE START OF CONSTRUCTION. TANGENT DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. UTILITY NOTE THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM RECORD INFORMATION. THE INFORMATION PROVIDED IS IMPLIED NOT INTENDED TO BE A COMPLETE INVENTORY OF THE UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. SCOPE OF WORK DETAIL: GENERAL: • NEW GENERAC DIESEL GENERATOR PROVIDED BY GENERAL DYNAMICS & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS GD-1 AND GD-2. • NEW CONCRETE PAD PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEET S-1. • NEW GENERAC AUTOMATIC TRANSFER SWITCH PROVIDED BY GENERAL DYNAMICS & INSTALLED BY CONTRACTOR. SEE SHEETS E-1, E-3, GD-2. • CONTRACTOR TO VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL RESTORE & REPAIR ANY DAMAGED AREAS CAUSED BY CONSTRUCTION TO ORIGINAL OR BETTER CONDITION. • INNER AND OUTER TANK TESTING DOCUMENTATION SHALL BE PROVIDED ONCE TANK IS IN PLACE ON SITE IN ACCORDANCE WITH NFPA 30. • A CALIBRATION CHART OF PERMANENT AND DURABLE CONSTRUCTION SHALL BE LOCATED AT THE FILL BOX. CONDUITS • INSTALL PULL STRING IN EACH CONDUIT. • (2) NEW ELECTRICAL CONDUITS WITH CONDUCTORS TO BE INSTALLED FROM NEW GENERATOR TO NEW ATS. CONDUIT PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2, E-3, G-1. • (2) NEW ELECTRICAL CONDUITS WITH CONDUCTORS TO BE INSTALLED FROM NEW GENERATOR TO AC PANEL. CONDUIT PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2, E-3, G-1. • (1) NEW ALARM CONDUIT & CABLING PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2, E-3, G-1. GROUNDING: • NEW EXOTHERMIC CONNECTION FROM EXISTING GROUND RING TO NEW MECHANICAL CONNECTION AT GENERATOR CHASSIS. GENERAL CONTRACTOR TO VERIFY LOCATION IN FIELD. LOCATE GROUND RODS NO MORE THAN 8'-0" APART. SEE SHEET E-2, E-3, G-1. H-FRAME: • CONTRACTOR TO PROVIDE NEW H-FRAME FOR ATS INSTALLATION (IF REQUIRED). MATCH EXISTING H-FRAME MATERIAL FOR CONSTRUCTION OF NEW H-FRAME. SEE SHEET E-3. POWER ROUTING KEYED NOTES: M/D EXISTING AT&T METER AND DISCONNECT INTERCEPT EXISTING CONDUIT AND CONDUCTORS AT DISCONNECT AND INT RE-ROUTE THROUGH PROPOSED ATS. COORDINATE PATH WITH CONSTRUCTION MANAGER. q EXISTING AC LOAD CENTER PROPOSED AT&T UNDERGROUND CONDUIT ROUTE. CONTRACTOR TO CON LOCATE EXISTING UTILITIES PRIOR TO EXCAVATION. SEE SHEETS E-1, E-2, E-3, G-1. SEE SHEET E-1 FOR SINGLE LINE DIAGRAM. PROPOSED AT&T 30KW DIESEL GENERATOR W/ SOUND ATTENUATED GEN ENCLOSURE, NORMAL / EMERGENCY TANK VENTING AND BASE FUEL TANK. SEE SHEETS GD-1 AND GD-2. OFUEL FILL SHALL BE PROVIDED WITH SPILL CONTROL, WITH A SOLID FILL CONNECTION, AND WITH OVERFILL PREVENTION. OFUEL TANK NORMAL AND EMERGENCY VENTS SHALL TERMINATE AT LEAST 12'-0" ABOVE THE ADJACENT GRADE. SEE SHEET GD-4. O NFPA 704 PLACARD AND OTHER SIGNAGE. SEE SHEET SG-1. FIRE EXTINGUISHER, (2A-20BC OR APPROVED EQUAL) PER CFC 906.3 FIRE FIRE EXTINGUISHER CABINET (BFC-7009 OR APPROVED EQUAL), MOUNTED TO WALL OR H-FRAME PER CFC 906.9 (5'-0" MAX ABOVE GRADE) OFF LOCKABLE EMERGENCY SHUTOFF SWITCH, MOUNTED TO WALL OR H-FRAME PER CFC 906.9 (5'-0- MAX ABOVE GRADE) ATS PROPOSED ATS W/ CAMLOCK MOUNTED TO WALL OR H-FRAME WITH 36" FRONT CLEARANCE. SEE SHEET GD-2. NOTE: 1. EVERYTHING SHOWN IS EXISTING UNLESS MARKED NEW 2. CONTRACTOR TO PROVIDE REQUIRED SIGNAGE FOR ELECTRICAL PANELS, DISCONNECTS, TRANSFER SWITCHES, ETC PER CALIFORNIA ELECTRICAL CODE ARTICLE 702.7 EXISTING AT&T PDU CABINET 2 EXISTING AT&T DC-12 BOX EXISTING IRON FENCE EXISTING CONCRETE CURB EXISTING METER CABINET WITH EXISTING AT&T METER EXISTING METER CABINET NEW ATS WITH CAMLOCK E 3 e NEW GENERAC SDO30 3OKW DIESEL GENERATOR PER MANUFACTURERS SPECIFICATIONS, GENERATOR e IS 7'-7" HIGH FROM TOP OF SLAB. PER NFPA D- 110 - OPTION REQUIRED STANDBY at &t GENERAL DYNAMICS Information Technology Tangent 2VORBA Ll-, c 92ee)I DRAWN BY: CF CHECKED BY: MR 5 01/19/2023 100% CD'S - CX COMMENTS RM 4 09/20/2022 100% CD'S - CX COMMENTS TJ 07/20/2022 100%CD'S -JX COMMENTS RM 2 06/08/2022 100% CD'S - CX COMMENTS RM 1 04/07/2022 100% CD'S - ILL COMMENTS I OIL 0 02/10/2022 100% CD'S FOR SUBMITTAL SM A 10/15/2021 90%CD'S FOR REVIEW CIF REVI DATE I DESCRIPTION BY THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION. CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. AT&T SITE NUMBER: 10101393 AT&T SITE NAME: IRVINE / JAMBOREE 12850 ROBINSON DRIVE TUSTIN, CA 92782 GENERATOR INSTALLATION PROJECT SHEET TITLE NEW EQUIPMENT PLAN SHEET NUMBER A-4 NOTES NEW EQUIPMENT PLAN 24"x36" SCALE: 1/2" = 1'-0" 0" 1' 2' 4 11"x17" SCALE: 1/4" = V-O" DocuSign Envelope ID: F5B9B721-6016-49F9-9B8B-4ED6E5B475C9 TOP OF STADIUM LIGHT POLE 69'-9" A.G.L. i, TOP OF (E) AT&T EQUIPMENT 62'-0" A.G.L. i, TOP OF (E1 SCORE BOARD 23'-0" A.G.L. TOP OF E WROUGHT IRON FENCE 8'-0" A.G.L. EXISTING EAST ELEVATION 24"x36" SCALE: 1/8" = 1'-0" 4' 8' 6' I A I 11"x17" SCALE: 1/16"= 1'-0" 1 * TOP OF STADIUM LIGHT POLE 69'-9" A.G.L. TOP OF E AT&T EQUIPMENT 62'-0" A.G.L. TOP OF E SCORE BOARD 23'-0" A.G.L. TOP OF N VENTPIPES 12'-0" A.G.L. TOP OF N GENERATOR 8'A.G.L. TOP OF WROUGHT IRON FENCE 8'-0" A.G LE GROUND 0'-0"A.G.L. -' at&t GENERAL DYNAMICS Information Technology Tangent DRAWN BY: CF CHECKED BY: MR 5 01/19/2023 100% CD'S - CX COMMENTS RM 4 09/20/2022 100% CD'S - CX COMMENTS TJ 07/20/2022 100%CD'S -JX COMMENTS RM 2 O6/08/2022 100% CD'S - CX COMMENTS RM 1 04/07/2022 100% CD'S - LL COMMENTS DL 0 02/10/2022 100% CD'S FOR SUBMITTAL SM A 10/15/2021 90%CD'S FOR REVIEW CF REV DATE DESCRIPTION BY THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION. CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. AT&T SITE NUMBER: 10101393 AT&T SITE NAME: IRVINE / JAMBOREE 12850 ROBINSON DRIVE TUSTIN, CA 92782 GENERATOR INSTALLATION PROJECT SHEET TITLE EXISTING AND NEW ELEVATIONS SHEET NUMBER A-5 NEW EAST ELEVATION 24"x36 SCALE: 1/8" = 1'-0" 11"x17" SCALE: 1/16"= V-0"