HomeMy WebLinkAboutPCM 11162023LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332320010
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:11/17/2023 12:30 PM
North Little Rock, AR 72118 Analysis Date:11/17/2023
Collected Date:11/16/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1116AS003A 11/16/2023 1325.2 <5.5 100 0.0020 <7.01 <0.0020
332320010-0001
TUCA1116AS004A 11/16/2023 1307.47 <5.5 100 0.0021 <7.01 <0.0021
332320010-0002
TUCA1116AS005A 11/16/2023 1292.07 <5.5 100 0.0021 <7.01 <0.0021
332320010-0003
TUCA1116AS006A 11/16/2023 919.18 <5.5 100 0.0029 <7.01 <0.0029
332320010-0004
TUCA1116AS007A 11/16/2023 764.75 <5.5 100 0.0035 <7.01 <0.0035
332320010-0005
TUCA1116AS008A 11/16/2023 1229.8 <5.5 100 0.0022 <7.01 <0.0022
332320010-0006
TUCA1116AS009A 11/16/2023 625.87 <5.5 100 0.0043 <7.01 <0.0043
332320010-0007
TUCA1116AS010A 11/16/2023 1188.48 <5.5 100 0.0023 <7.01 <0.0023
332320010-0008
TUCA1116ASFB001A 11/16/2023 <5.5 100 <7.01 Field Blank
332320010-0009
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Thanh Nguyen PCM 9
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 11/17/2023 04:00 PM
Printed: 11/17/2023 04:00 PM ASB_PCM_NoSig_0003_0001 Page 1 of 1