HomeMy WebLinkAboutPCM 11242023BLA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332320363
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:11/25/2023 10:00 AM
North Little Rock, AR 72118 Analysis Date:11/25/2023
Collected Date:11/24/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1124AS001B 11/24/2023 1426.6 <5.5 100 0.0019 <7.01 <0.0019
332320363-0001
TUCA1124AS002B 11/24/2023 1425.2 <5.5 100 0.0019 <7.01 <0.0019
332320363-0002
TUCA1124AS003B 11/24/2023 1433.8 <5.5 100 0.0019 <7.01 <0.0019
332320363-0003
TUCA1124AS004B 11/24/2023 1420.5 <5.5 100 0.0019 <7.01 <0.0019
332320363-0004
TUCA1124AS005B 11/24/2023 1429.1 <5.5 100 0.0019 <7.01 <0.0019
332320363-0005
TUCA1124AS006B 11/24/2023 1418.6 <5.5 100 0.0019 <7.01 <0.0019
332320363-0006
TUCA1124AS007B 11/24/2023 1424.2 <5.5 100 0.0019 <7.01 <0.0019
332320363-0007
TUCA1124AS008B 11/24/2023 1428 <5.5 100 0.0019 <7.01 <0.0019
332320363-0008
TUCA1124AS009B 11/24/2023 1408.8 <5.5 100 0.0019 <7.01 <0.0019
332320363-0009
TUCA1124AS010B 11/24/2023 1431.1 <5.5 100 0.0019 <7.01 <0.0019
332320363-0010
TUCA1124ASFB001B 11/24/2023 <5.5 100 <7.01 Field Blank
332320363-0011
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Mindy Le PCM 11
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 11/25/2023 12:51 PM
Printed: 11/25/2023 12:51 PM ASB_PCM_NoSig_0003_0001 Page 1 of 1