HomeMy WebLinkAboutPCM 11252023ALA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332320398
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:11/27/2023 09:50 AM
North Little Rock, AR 72118 Analysis Date:11/27/2023
Collected Date:11/25/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1125AS001A 11/25/2023 1437.9 <5.5 100 0.0019 <7.01 <0.0019
332320398-0001
TUCA1125AS002A 11/25/2023 1398.1 <5.5 100 0.0019 <7.01 <0.0019
332320398-0002
TUCA1125AS003A 11/25/2023 1434.5 <5.5 100 0.0019 <7.01 <0.0019
332320398-0003
TUCA1125AS005A 11/25/2023 1434.5 <5.5 100 0.0019 <7.01 <0.0019
332320398-0004
TUCA1125AS006A 11/25/2023 1430.9 <5.5 100 0.0019 <7.01 <0.0019
332320398-0005
TUCA1125AS007A 11/25/2023 1411.7 <5.5 100 0.0019 <7.01 <0.0019
332320398-0006
TUCA1125AS008A 11/25/2023 1448.9 <5.5 100 0.0019 <7.01 <0.0019
332320398-0007
TUCA1125AS009A 11/25/2023 1413.4 <5.5 100 0.0019 <7.01 <0.0019
332320398-0008
TUCA1125AS010A 11/25/2023 1456.5 <5.5 100 0.0019 <7.01 <0.0019
332320398-0009
TUCA1125ASFB001A 11/25/2023 <5.5 100 <7.01 Field Blank
332320398-0010
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 10
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 11/27/2023 03:25 PM
Printed: 11/27/2023 03:25 PM ASB_PCM_NoSig_0003_0001 Page 1 of 1