HomeMy WebLinkAboutPCM 11292023ALA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332320623
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:11/30/2023 12:05 PM
North Little Rock, AR 72118 Analysis Date:11/30/2023
Collected Date:11/29/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1129AS001A 11/29/2023 1100.1 <5.5 100 0.0024 <7.01 <0.0024
332320623-0001
TUCA1129AS002A 11/29/2023 1114.4 <5.5 100 0.0024 <7.01 <0.0024
332320623-0002
TUCA1129AS003A 11/29/2023 1243.4 <5.5 100 0.0022 <7.01 <0.0022
332320623-0003
TUCA1129AS004A 11/29/2023 1096.1 <5.5 100 0.0025 <7.01 <0.0025
332320623-0004
TUCA1129AS005A 11/29/2023 1130.9 <5.5 100 0.0024 <7.01 <0.0024
332320623-0005
TUCA1129AS006A 11/29/2023 1142.6 <5.5 100 0.0024 <7.01 <0.0024
332320623-0006
TUCA1129AS007A 11/29/2023 848.5 <5.5 100 0.0032 <7.01 <0.0032
332320623-0007
TUCA1129AS008A 11/29/2023 1031.3 <5.5 100 0.0026 <7.01 <0.0026
332320623-0008
TUCA1129AS009A 11/29/2023 1417.8 <5.5 100 0.0019 <7.01 <0.0019
332320623-0009
TUCA1129AS010A 11/29/2023 1272.8 <5.5 100 0.0021 <7.01 <0.0021
332320623-0010
TUCA1129AS013A 11/29/2023 1244.2 <5.5 100 0.0022 <7.01 <0.0022
332320623-0011
TUCA1129AS014A 11/29/2023 869.8 <5.5 100 0.0031 <7.01 <0.0031
332320623-0012
TUCA1129AS015A 11/29/2023 1251.5 <5.5 100 0.0022 <7.01 <0.0022
332320623-0013
TUCA1129AS017A 11/29/2023 998.8 <5.5 100 0.0027 <7.01 <0.0027
332320623-0014
TUCA1129AS018A 11/29/2023 791.5 <5.5 100 0.0034 <7.01 <0.0034
332320623-0015
TUCA1129AS019A 11/29/2023 794.5 <5.5 100 0.0034 <7.01 <0.0034
332320623-0016
TUCA1129AS021A 11/29/2023 943.6 <5.5 100 0.0029 <7.01 <0.0029
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 11/30/2023 03:42 PM
Printed: 11/30/2023 03:42 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332320623
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:11/30/2023 12:05 PM
North Little Rock, AR 72118 Analysis Date:11/30/2023
Collected Date:11/29/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332320623-0017
TUCA1129ASFB001A 11/29/2023 <5.5 100 <7.01 Field Blank
332320623-0018
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Mindy Le PCM 18
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 11/30/2023 03:42 PM
Printed: 11/30/2023 03:42 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2