Loading...
HomeMy WebLinkAboutTEM 11172023ALA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332320078 Customer ID:32ACGP78 Customer PO: Project ID: Attention:Ben Regester Phone:(805) 676-0187 Analytical Consulting Group, Inc.Fax: 1746 F South Victoria Avenue Received Date:11/20/2023 08:00 AM Suite 366 Analysis Date:11/20/2023 Ventura, CA 93003 Collected Date:11/17/2023 I1500 BGI TUSTIN HANGAR FIREProject: Test Report: Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Appendix A to Subpart E Sample Location Asbestos Concentration (S/cc)(S/mm²) Analytical Sensitivity (S/cc)≥5μ≥0.5μ < 5μ #StructuresAsbestos Type(s) Non Asb Area Analyzed (mm²) Volume (Liters) TUS-20231117-C A1-AA01-60-TEM OCHCA 3595.00 0.0508 0 None Detected 0 0 0.0021 <20.00 <0.0021 332320078-0001 TUS-20231117-L P1-AA01-60-TEM TUSTIN LEGACY PARK 3800.00 0.0508 0 None Detected 0 0 0.0020 <20.00 <0.0020 332320078-0002 TUS-20231117-D C1-AA01-60-TEM THE DISTRICT (COSTCO) 3685.00 0.0508 0 None Detected 0 0 0.0021 <20.00 <0.0021 332320078-0003 TUS-20231117- WR1-AA01-60-T EM WR NELSON ELEMENTARY 3625.00 0.0508 0 None Detected 0 0 0.0021 <20.00 <0.0021 332320078-0004 TUS-20231117-H S1-AA01-60-TEM TUSTIN HS 640.00 0.1270 0 None Detected 0 0 0.0047 <7.90 <0.0047 332320078-0005 TUS-20231117-C A1-AA02-60-TEM OCHCA 3470.00 0.0508 0 None Detected 0 0 0.0022 <20.00 <0.0022 332320078-0006 TUS-20231117-L P1-AA02-60-TEM TUSTIN LEGACY PARK 3330.00 0.0508 0 None Detected 0 0 0.0023 <20.00 <0.0023 332320078-0007 TUS-20231117-D C1-AA02-60-TEM THE DISTRICT (COSTCO) 3375.00 0.0508 0 None Detected 0 0 0.0022 <20.00 <0.0022 332320078-0008 TUS-20231117- WR1-AA02-60-T EM WR NELSON ELEMENTARY 3575.00 0.0508 0 None Detected 0 0 0.0021 <20.00 <0.0021 332320078-0009 TUS-20231117-H C1-AA02-60-TEM HICKS CANYON ELEMENTARY 1330.00 0.0635 0 None Detected 0 0 0.0046 <16.00 <0.0046 332320078-0010 TUS-20231117-F S21-AA02-60-TE M FIRE STATION 21 3385.00 0.0508 0 None Detected 0 0 0.0022 <20.00 <0.0022 332320078-0011 TUS-20231117-C H1-AA02-60-TEM CENTURY HS 2235.00 0.0508 0 None Detected 0 0 0.0034 <20.00 <0.0034 332320078-0012 TUS-20231117-F S28-AA02-60-TE M FIRE STATION 28 4840.00 0.0508 0 None Detected 0 0 0.0016 <20.00 <0.0016 332320078-0013 TUS-20231117-F S6-AA02-60-TEM FIRE STATION 6 4108.00 0.0508 0 None Detected 0 0 0.0018 <20.00 <0.0018 332320078-0014 Initial report from: 11/20/2023 16:51 PM ASB_TEMAHERA_0004_0001 Printed: 11/20/2023 4:51:31PM Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332320078 Customer ID:32ACGP78 Customer PO: Project ID: Attention:Ben Regester Phone:(805) 676-0187 Analytical Consulting Group, Inc.Fax: 1746 F South Victoria Avenue Received Date:11/20/2023 08:00 AM Suite 366 Analysis Date:11/20/2023 Ventura, CA 93003 Collected Date:11/17/2023 I1500 BGI TUSTIN HANGAR FIREProject: Test Report: Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Appendix A to Subpart E Sample Location Asbestos Concentration (S/cc)(S/mm²) Analytical Sensitivity (S/cc)≥5μ≥0.5μ < 5μ #StructuresAsbestos Type(s) Non Asb Area Analyzed (mm²) Volume (Liters) Analyst(s) Mindy Le (10) Christopher Miranda (4) Michael Chapman, Laboratory Manager or other approved signatory LA Testing maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing . LA Testing bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Results reported in structures/cm3 are not covered by the laboratory's NVLAP accreditation . Measurement of uncertainty available upon request. Samples analyzed by LA Testing Huntington Beach, CA NVLAP Lab Code 101384-0 Initial report from: 11/20/2023 16:51 PM ASB_TEMAHERA_0004_0001 Printed: 11/20/2023 4:51:31PM Page 2 of 2