Loading...
HomeMy WebLinkAboutTEM 11202023LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332320224 Customer ID:32ACGP78 Customer PO: Project ID: Attention:Michael Tiffany Phone:(805) 676-0187 Analytical Consulting Group, Inc.Fax: 1746 F South Victoria Avenue Received Date:11/22/2023 08:00 AM Suite 366 Analysis Date:11/22/2023 Ventura, CA 93003 Collected Date:11/20/2023 BGI TUSTIN HANGAR FIRE / I1500Project: Test Report: Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Appendix A to Subpart E Sample Location Asbestos Concentration (S/cc)(S/mm²) Analytical Sensitivity (S/cc)≥5μ≥0.5μ < 5μ #StructuresAsbestos Type(s) Non Asb Area Analyzed (mm²) Volume (Liters) TUS-20231120-C A1-AA01-60-TEM OCHCA 3475.00 0.0272 1 None Detected 0 0 0.0041 <37.00 <0.0041 332320224-0001 TUS-20231120-L P1-AA01-60-TEM TUSTIN LEGACY PARK 3235.00 0.0272 0 None Detected 0 0 0.0044 <37.00 <0.0044 332320224-0002 TUS-20231120-D C1-AA01-60-TEM THE DISTRICT (COSTCO) 3350.00 0.0272 0 None Detected 0 0 0.0042 <37.00 <0.0042 332320224-0003 TUS-20231120- WR1-AA01-60-T EM WR NELSON ELMENTARY 3225.00 0.0272 0 None Detected 0 0 0.0044 <37.00 <0.0044 332320224-0004 TUS-20231120-H S1-AA01-60-TEM TUSTIN HS 3125.00 0.0272 0 None Detected 0 0 0.0045 <37.00 <0.0045 332320224-0005 TUS-20231120-H C1-AA01-60-TEM HICKS CANYON ELEMENTARY 3200.00 0.0272 0 None Detected 0 0 0.0044 <37.00 <0.0044 332320224-0006 TUS-20231120-C H1-AA01-60-TEM CENTURY HS 3675.00 0.0272 0 None Detected 0 0 0.0038 <37.00 <0.0038 332320224-0007 TUS-20231120-F S281-AA01-60-T EM FIRE STATION 28 3350.00 0.0272 1 None Detected 0 0 0.0042 <37.00 <0.0042 332320224-0008 TUS-20231120-F S61-AA01-60-TE M FIRE STATION 6 3375.00 0.0272 0 None Detected 0 0 0.0042 <37.00 <0.0042 332320224-0009 TUS-20231120-C A2-AA01-60-TEM OCHCA 3775.00 0.0272 0 None Detected 0 0 0.0037 <37.00 <0.0037 332320224-0010 TUS-20231120-L P2-AA01-60-TEM TUSTIN LEGACY PARK 3955.00 0.0272 0 None Detected 0 0 0.0036 <37.00 <0.0036 332320224-0011 TUS-20231120-D C2-AA01-60-TEM THE DISTRICT (COSTCO) 3825.00 0.0272 0 None Detected 0 0 0.0037 <37.00 <0.0037 332320224-0012 TUS-20231120- WR2-AA01-60-T EM WR NELSON ELEMENTARY 3850.00 0.0272 0 None Detected 0 0 0.0037 <37.00 <0.0037 332320224-0013 TUS-20231120-H S2-AA01-60-TEM TUSTIN HS 3825.00 0.0272 0 None Detected 0 0 0.0037 <37.00 <0.0037 332320224-0014 TUS-20231120-H C2-AA01-60-TEM HICKS CANYON ELEMENTARY 1115.00 0.0681 0 None Detected 0 0 0.0051 <15.00 <0.0051 Initial report from: 11/22/2023 17:41 PM ASB_TEMAHERA_0004_0001 Printed: 11/22/2023 5:41:58PM Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332320224 Customer ID:32ACGP78 Customer PO: Project ID: Attention:Michael Tiffany Phone:(805) 676-0187 Analytical Consulting Group, Inc.Fax: 1746 F South Victoria Avenue Received Date:11/22/2023 08:00 AM Suite 366 Analysis Date:11/22/2023 Ventura, CA 93003 Collected Date:11/20/2023 BGI TUSTIN HANGAR FIRE / I1500Project: Test Report: Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Appendix A to Subpart E Sample Location Asbestos Concentration (S/cc)(S/mm²) Analytical Sensitivity (S/cc)≥5μ≥0.5μ < 5μ #StructuresAsbestos Type(s) Non Asb Area Analyzed (mm²) Volume (Liters) 332320224-0015 TUS-20231120-F S212-AA01-60-T EM FIRE STATION 21 3875.00 0.0272 0 None Detected 0 0 0.0036 <37.00 <0.0036 332320224-0016 TUS-20231120-C H2-AA01-60-TEM CENTURY HS 3145.00 0.0272 0 None Detected 0 0 0.0045 <37.00 <0.0045 332320224-0017 TUS-20231120-F S282-AA01-60-T EM FIRE STATION 28 1210.00 0.0681 0 None Detected 0 0 0.0047 <15.00 <0.0047 332320224-0018 TUS-20231120-F S62-AA01-60-TE M FIRE STATION 6 3325.00 0.0272 0 None Detected 0 0 0.0043 <37.00 <0.0043 332320224-0019 Analyst(s) Christopher Miranda (19)Michael Chapman, Laboratory Manager or other approved signatory LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. This report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Results reported in structures/cm3 are not covered by the laboratory's NVLAP accreditation. Measurement of uncertainty available upon request. Samples analyzed by LA Testing Huntington Beach, CA NVLAP Lab Code 101384-0 Initial report from: 11/22/2023 17:41 PM ASB_TEMAHERA_0004_0001 Printed: 11/22/2023 5:41:58PM Page 2 of 2