HomeMy WebLinkAboutPCM 12022023ALA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332320774
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/04/2023 11:40 AM
North Little Rock, AR 72118 Analysis Date:12/04/2023
Collected Date:12/02/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1202AS001A 12/02/2023 1443.9 <5.5 100 0.0019 <7.01 <0.0019
332320774-0001
TUCA1202AS002A 12/02/2023 1430.2 <5.5 100 0.0019 <7.01 <0.0019
332320774-0002
TUCA1202AS003A 12/02/2023 1445.1 7 100 0.0019 8.92 0.0024
332320774-0003
TUCA1202AS004A 12/02/2023 1083.9 <5.5 100 0.0025 <7.01 <0.0025
332320774-0004
TUCA1202AS005A 12/02/2023 1450.5 6 100 0.0019 7.64 0.0020
332320774-0005
TUCA1202AS006A 12/02/2023 1395.7 <5.5 100 0.0019 <7.01 <0.0019
332320774-0006
TUCA1202AS007A 12/02/2023 1404 <5.5 100 0.0019 <7.01 <0.0019
332320774-0007
TUCA1202AS008A 12/02/2023 1424.1 <5.5 100 0.0019 <7.01 <0.0019
332320774-0008
TUCA1202AS009A 12/02/2023 1433.4 <5.5 100 0.0019 <7.01 <0.0019
332320774-0009
TUCA1202AS010A 12/02/2023 1432.7 <5.5 100 0.0019 <7.01 <0.0019
332320774-0010
TUCA1202AS013A 12/02/2023 1381.4 <5.5 100 0.0020 <7.01 <0.0020
332320774-0011
TUCA1202AS014A 12/02/2023 1100.9 <5.5 100 0.0024 <7.01 <0.0024
332320774-0012
TUCA1202AS015A 12/02/2023 1383.5 <5.5 100 0.0019 <7.01 <0.0019
332320774-0013
TUCA1202AS017A 12/02/2023 1243.4 <5.5 100 0.0022 <7.01 <0.0022
332320774-0014
TUCA1202AS018A 12/02/2023 922.9 <5.5 100 0.0029 <7.01 <0.0029
332320774-0015
TUCA1202AS019A 12/02/2023 1445.8 6 100 0.0019 7.64 0.0020
332320774-0016
TUCA1202AS021A 12/02/2023 1380.6 <5.5 100 0.0020 <7.01 <0.0020
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/04/2023 02:25 PM
Printed: 12/04/2023 02:26 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332320774
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/04/2023 11:40 AM
North Little Rock, AR 72118 Analysis Date:12/04/2023
Collected Date:12/02/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332320774-0017
TUCA1202ASFB001A 12/02/2023 <5.5 100 <7.01 Field Blank
332320774-0018
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Alexis Rodriguez PCM 18
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/04/2023 02:25 PM
Printed: 12/04/2023 02:26 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2