HomeMy WebLinkAboutPCM 12032023BLA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332320770
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/04/2023 11:40 AM
North Little Rock, AR 72118 Analysis Date:12/04/2023
Collected Date:12/03/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1203AS001B 12/03/2023 1373.4 <5.5 100 0.0020 <7.01 <0.0020
332320770-0001
TUCA1203AS002B 12/03/2023 1392.8 9 100 0.0019 11.5 0.0032
332320770-0002
TUCA1203AS003B 12/03/2023 1401.7 <5.5 100 0.0019 <7.01 <0.0019
332320770-0003
TUCA1203AS004B 12/03/2023 1398.3 <5.5 100 0.0019 <7.01 <0.0019
332320770-0004
TUCA1203AS005B 12/03/2023 1301.1 <5.5 100 0.0021 <7.01 <0.0021
332320770-0005
TUCA1203AS006B 12/03/2023 1370.2 <5.5 100 0.0020 <7.01 <0.0020
332320770-0006
TUCA1203AS007B 12/03/2023 1378.9 <5.5 100 0.0020 <7.01 <0.0020
332320770-0007
TUCA1203AS008B 12/03/2023 1388.1 <5.5 100 0.0019 <7.01 <0.0019
332320770-0008
TUCA1203AS009B 12/03/2023 1412.6 <5.5 100 0.0019 <7.01 <0.0019
332320770-0009
TUCA1203AS010B 12/03/2023 1411.2 <5.5 100 0.0019 <7.01 <0.0019
332320770-0010
TUCA1203ASFB001B 12/03/2023 <5.5 100 <7.01 Field Blank
332320770-0011
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Alexis Rodriguez PCM 11
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/04/2023 03:05 PM
Printed: 12/04/2023 03:05 PM ASB_PCM_NoSig_0003_0001 Page 1 of 1