Loading...
HomeMy WebLinkAboutPCM 12122023ALA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332321332 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:12/13/2023 11:25 AM North Little Rock, AR 72118 Analysis Date:12/13/2023 Collected Date:12/12/2023 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/15/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA1212AS001A 12/12/2023 1373.4 <5.5 100 0.0020 <7.01 <0.0020 332321332-0001 TUCA1212AS002A 12/12/2023 1391.6 <5.5 100 0.0019 <7.01 <0.0019 332321332-0002 TUCA1212AS003A 12/12/2023 1386.2 <5.5 100 0.0019 <7.01 <0.0019 332321332-0003 TUCA1212AS004A 12/12/2023 1352.5 <5.5 100 0.0020 <7.01 <0.0020 332321332-0004 TUCA1212AS005A 12/12/2023 1389.4 <5.5 100 0.0019 <7.01 <0.0019 332321332-0005 TUCA1212AS006A 12/12/2023 1383.3 <5.5 100 0.0019 <7.01 <0.0019 332321332-0006 TUCA1212AS007A 12/12/2023 1346.4 <5.5 100 0.0020 <7.01 <0.0020 332321332-0007 TUCA1212AS008A 12/12/2023 1396.6 <5.5 100 0.0019 <7.01 <0.0019 332321332-0008 TUCA1212AS009A 12/12/2023 742.3 7 100 0.0036 8.92 0.0046 332321332-0009 TUCA1212AS010A 12/12/2023 1427.2 <5.5 100 0.0019 <7.01 <0.0019 332321332-0010 TUCA1212AS014A 12/12/2023 1288.1 <5.5 100 0.0021 <7.01 <0.0021 332321332-0011 TUCA1212AS015A 12/12/2023 1403.3 <5.5 100 0.0019 <7.01 <0.0019 332321332-0012 TUCA1212AS017A 12/12/2023 1418.4 <5.5 100 0.0019 <7.01 <0.0019 332321332-0013 TUCA1212AS018A 12/12/2023 1143.9 <5.5 100 0.0024 <7.01 <0.0024 332321332-0014 TUCA1212AS019A 12/12/2023 1326.7 <5.5 100 0.0020 <7.01 <0.0020 332321332-0015 TUCA1212AS021A 12/12/2023 1379.3 <5.5 100 0.0020 <7.01 <0.0020 332321332-0016 TUCA1212AFB001A 12/12/2023 <5.5 100 <7.01 Field Blank LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 12/13/2023 04:38 PM Printed: 12/13/2023 04:39 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332321332 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:12/13/2023 11:25 AM North Little Rock, AR 72118 Analysis Date:12/13/2023 Collected Date:12/12/2023 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/15/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332321332-0017 The results reported have been blank corrected as applicable. Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Thanh Nguyen PCM 17 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 12/13/2023 04:38 PM Printed: 12/13/2023 04:39 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2