Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1217AS001A 12/17/2023 1020.8 <5.5 100 0.0026 <7.01 <0.0026
332321587-0001
TUCA1217AS002A 12/17/2023 1063.9 <5.5 100 0.0025 <7.01 <0.0025
332321587-0002
TUCA1217AS003A 12/17/2023 1055.5 <5.5 100 0.0026 <7.01 <0.0026
332321587-0003
TUCA1217AS004A 12/17/2023 1042.2 <5.5 100 0.0026 <7.01 <0.0026
332321587-0004
TUCA1217AS005A 12/17/2023 823.3 <5.5 100 0.0033 <7.01 <0.0033
332321587-0005
TUCA1217AS006A 12/17/2023 1002.4 <5.5 100 0.0027 <7.01 <0.0027
332321587-0006
TUCA1217AS007A 12/17/2023 1021.5 <5.5 100 0.0026 <7.01 <0.0026
332321587-0007
TUCA1217AS008A 12/17/2023 1018.7 <5.5 100 0.0026 <7.01 <0.0026
332321587-0008
TUCA1217AS009A 12/17/2023 998.6 <5.5 100 0.0027 <7.01 <0.0027
332321587-0009
TUCA1217AS010A 12/17/2023 937.1 <5.5 100 0.0029 <7.01 <0.0029
332321587-0010
TUCA1217AS013A 12/17/2023 907.2 <5.5 100 0.0030 <7.01 <0.0030
332321587-0011
TUCA1217AS014A 12/17/2023 659 <5.5 100 0.0041 <7.01 <0.0041
332321587-0012
TUCA1217AS015A 12/17/2023 1073.4 <5.5 100 0.0025 <7.01 <0.0025
332321587-0013
TUCA1217AS017A 12/17/2023 996.3 <5.5 100 0.0027 <7.01 <0.0027
332321587-0014
TUCA1217AS018A 12/17/2023 494.2 <5.5 100 0.0055 <7.01 <0.0055
332321587-0015
TUCA1217AS019A 12/17/2023 792.3 <5.5 100 0.0034 <7.01 <0.0034
332321587-0016
TUCA1217AS021A 12/17/2023 1075.7 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/18/2023 03:01 PM
Printed: 12/18/2023 03:01 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332321587
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/18/2023 11:45 AM
North Little Rock, AR 72118 Analysis Date:12/18/2023
Collected Date:12/17/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332321587-0017
TUCA1217ASFB001A 12/17/2023 <5.5 100 <7.01 Field Blank
332321587-0018
TUCA1217AS001B 12/17/2023 1031 <5.5 100 0.0026 <7.01 <0.0026
332321587-0019
TUCA1217AS002B 12/17/2023 1039.3 <5.5 100 0.0026 <7.01 <0.0026
332321587-0020
TUCA1217AS003B 12/17/2023 1028.8 <5.5 100 0.0026 <7.01 <0.0026
332321587-0021
TUCA1217AS004B 12/17/2023 926.1 <5.5 100 0.0029 <7.01 <0.0029
332321587-0022
TUCA1217AS005B 12/17/2023 1070.2 <5.5 100 0.0025 <7.01 <0.0025
332321587-0023
TUCA1217AS006B 12/17/2023 1058.7 <5.5 100 0.0025 <7.01 <0.0025
332321587-0024
TUCA1217AS007B 12/17/2023 902.7 <5.5 100 0.0030 <7.01 <0.0030
332321587-0025
TUCA1217AS008B 12/17/2023 1062.9 <5.5 100 0.0025 <7.01 <0.0025
332321587-0026
TUCA1217AS009B 12/17/2023 1056.8 <5.5 100 0.0026 <7.01 <0.0026
332321587-0027
TUCA1217AS010B 12/17/2023 1014.7 <5.5 100 0.0027 <7.01 <0.0027
332321587-0028
TUCA1217ASFB001B 12/17/2023 <5.5 100 <7.01 Field Blank
332321587-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/18/2023 03:01 PM
Printed: 12/18/2023 03:01 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332321587
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Lab Results Phone:(501) 801-8500
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/18/2023 11:45 AM
North Little Rock, AR 72118 Analysis Date:12/18/2023
Collected Date:12/17/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650