Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1220AS001A 12/20/2023 1059.5 <5.5 100 0.0025 <7.01 <0.0025
332321787-0001
TUCA1220AS002A 12/20/2023 1055.8 <5.5 100 0.0026 <7.01 <0.0026
332321787-0002
TUCA1220AS003A 12/20/2023 1066.6 <5.5 100 0.0025 <7.01 <0.0025
332321787-0003
TUCA1220AS004A 12/20/2023 1001.1 <5.5 100 0.0027 <7.01 <0.0027
332321787-0004
TUCA1220AS005A 12/20/2023 1041.7 <5.5 100 0.0026 <7.01 <0.0026
332321787-0005
TUCA1220AS006A 12/20/2023 1034.3 <5.5 100 0.0026 <7.01 <0.0026
332321787-0006
TUCA1220AS007A 12/20/2023 956.9 <5.5 100 0.0028 <7.01 <0.0028
332321787-0007
TUCA1220AS008A 12/20/2023 1064.3 <5.5 100 0.0025 <7.01 <0.0025
332321787-0008
TUCA1220AS009A 12/20/2023 1056.7 <5.5 100 0.0026 <7.01 <0.0026
332321787-0009
TUCA1220AS010A 12/20/2023 1009.6 <5.5 100 0.0027 <7.01 <0.0027
332321787-0010
TUCA1220AS013A 12/20/2023 923.5 <5.5 100 0.0029 <7.01 <0.0029
332321787-0011
TUCA1220AS014A 12/20/2023 651.9 <5.5 100 0.0041 <7.01 <0.0041
332321787-0012
TUCA1220AS015A 12/20/2023 1051.5 <5.5 100 0.0026 <7.01 <0.0026
332321787-0013
TUCA1220AS017A 12/20/2023 991.6 <5.5 100 0.0027 <7.01 <0.0027
332321787-0014
TUCA1220AS018A 12/20/2023 1041.5 <5.5 100 0.0026 <7.01 <0.0026
332321787-0015
TUCA1220AS019A 12/20/2023 804.8 <5.5 100 0.0033 <7.01 <0.0033
332321787-0016
TUCA1220AS021A 12/20/2023 1054.8 <5.5 100 0.0026 <7.01 <0.0026
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/21/2023 02:32 PM
Printed: 12/21/2023 02:32 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332321787
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/21/2023 11:22 AM
North Little Rock, AR 72118 Analysis Date:12/21/2023
Collected Date:12/20/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332321787-0017
TUCA1220ASFB001A 12/20/2023 <5.5 100 <7.01 Field Blank
332321787-0018
TUCA1220AS001B 12/20/2023 1008.5 <5.5 100 0.0027 <7.01 <0.0027
332321787-0019
TUCA1220AS002B 12/20/2023 1016.5 <5.5 100 0.0027 <7.01 <0.0027
332321787-0020
TUCA1220AS003B 12/20/2023 1040 <5.5 100 0.0026 <7.01 <0.0026
332321787-0021
TUCA1220AS004B 12/20/2023 1035 <5.5 100 0.0026 <7.01 <0.0026
332321787-0022
TUCA1220AS005B 12/20/2023 837.8 <5.5 100 0.0032 <7.01 <0.0032
332321787-0023
TUCA1220AS006B 12/20/2023 1003.2 <5.5 100 0.0027 <7.01 <0.0027
332321787-0024
TUCA1220AS007B 12/20/2023 1032.4 <5.5 100 0.0026 <7.01 <0.0026
332321787-0025
TUCA1220AS008B 12/20/2023 1015.8 <5.5 100 0.0027 <7.01 <0.0027
332321787-0026
TUCA1220AS009B 12/20/2023 1001.6 <5.5 100 0.0027 <7.01 <0.0027
332321787-0027
TUCA1220AS010B 12/20/2023 932.7 <5.5 100 0.0029 <7.01 <0.0029
332321787-0028
TUCA1220ASFB001B 12/20/2023 <5.5 100 <7.01 Field Blank
332321787-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/21/2023 02:32 PM
Printed: 12/21/2023 02:32 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332321787
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/21/2023 11:22 AM
North Little Rock, AR 72118 Analysis Date:12/21/2023
Collected Date:12/20/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/21/2023 02:32 PM