Loading...
HomeMy WebLinkAboutPCM 12222023LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332321874 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:12/23/2023 10:45 AM North Little Rock, AR 72118 Analysis Date:12/23/2023 Collected Date:12/22/2023 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/15/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA1222AS001A 12/22/2023 1058.4 <5.5 100 0.0025 <7.01 <0.0025 332321874-0001 TUCA1222AS002A 12/22/2023 1061.5 <5.5 100 0.0025 <7.01 <0.0025 332321874-0002 TUCA1222AS003A 12/22/2023 1051.8 <5.5 100 0.0026 <7.01 <0.0026 332321874-0003 TUCA1222AS004A 12/22/2023 970.4 <5.5 100 0.0028 <7.01 <0.0028 332321874-0004 TUCA1222AS005A 12/22/2023 1066.5 <5.5 100 0.0025 <7.01 <0.0025 332321874-0005 TUCA1222AS006A 12/22/2023 1053.5 <5.5 100 0.0026 <7.01 <0.0026 332321874-0006 TUCA1222AS007A 12/22/2023 992.8 <5.5 100 0.0027 <7.01 <0.0027 332321874-0007 TUCA1222AS008A 12/22/2023 Filter was wet 332321874-0008 TUCA1222AS009A 12/22/2023 1058.2 <5.5 100 0.0025 <7.01 <0.0025 332321874-0009 TUCA1222AS010A 12/22/2023 1027.9 <5.5 100 0.0026 <7.01 <0.0026 332321874-0010 TUCA1222AS013A 12/22/2023 863.6 <5.5 100 0.0031 <7.01 <0.0031 332321874-0011 TUCA1222AS014A 12/22/2023 823 <5.5 100 0.0033 <7.01 <0.0033 332321874-0012 TUCA1222AS015A 12/22/2023 1062 <5.5 100 0.0025 <7.01 <0.0025 332321874-0013 TUCA1222AS017A 12/22/2023 1030 <5.5 100 0.0026 <7.01 <0.0026 332321874-0014 TUCA1222AS018A 12/22/2023 1019.3 <5.5 100 0.0026 <7.01 <0.0026 332321874-0015 TUCA1222AS019A 12/22/2023 1092.2 <5.5 100 0.0025 <7.01 <0.0025 332321874-0016 TUCA1222AS021A 12/22/2023 1058 <5.5 100 0.0025 <7.01 <0.0025 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 12/23/2023 02:59 PM Printed: 12/23/2023 02:59 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332321874 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:12/23/2023 10:45 AM North Little Rock, AR 72118 Analysis Date:12/23/2023 Collected Date:12/22/2023 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/15/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332321874-0017 TUCA1222ASFB001A 12/22/2023 <5.5 100 <7.01 Field Blank 332321874-0018 TUCA1222AS001B 12/22/2023 1170.7 <5.5 100 0.0023 <7.01 <0.0023 332321874-0019 TUCA1222AS002B 12/22/2023 1035.5 <5.5 100 0.0026 <7.01 <0.0026 332321874-0020 TUCA1222AS003B 12/22/2023 1029.3 <5.5 100 0.0026 <7.01 <0.0026 332321874-0021 TUCA1222AS004B 12/22/2023 1021.5 <5.5 100 0.0026 <7.01 <0.0026 332321874-0022 TUCA1222AS005B 12/22/2023 830.6 <5.5 100 0.0032 <7.01 <0.0032 332321874-0023 TUCA1222AS006B 12/22/2023 1004.2 <5.5 100 0.0027 <7.01 <0.0027 332321874-0024 TUCA1222AS008B 12/22/2023 997.2 <5.5 100 0.0027 <7.01 <0.0027 332321874-0025 TUCA1222AS009B 12/22/2023 974.8 <5.5 100 0.0028 <7.01 <0.0028 332321874-0026 TUCA1222AS010B 12/22/2023 921 <5.5 100 0.0029 <7.01 <0.0029 332321874-0027 TUCA1222ASFB001B 12/22/2023 <5.5 100 <7.01 Field Blank 332321874-0028 The results reported have been blank corrected as applicable. Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Mindy Le PCM 27 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 12/23/2023 02:59 PM Printed: 12/23/2023 02:59 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2