HomeMy WebLinkAboutPCM 12222023LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332321874
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/23/2023 10:45 AM
North Little Rock, AR 72118 Analysis Date:12/23/2023
Collected Date:12/22/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1222AS001A 12/22/2023 1058.4 <5.5 100 0.0025 <7.01 <0.0025
332321874-0001
TUCA1222AS002A 12/22/2023 1061.5 <5.5 100 0.0025 <7.01 <0.0025
332321874-0002
TUCA1222AS003A 12/22/2023 1051.8 <5.5 100 0.0026 <7.01 <0.0026
332321874-0003
TUCA1222AS004A 12/22/2023 970.4 <5.5 100 0.0028 <7.01 <0.0028
332321874-0004
TUCA1222AS005A 12/22/2023 1066.5 <5.5 100 0.0025 <7.01 <0.0025
332321874-0005
TUCA1222AS006A 12/22/2023 1053.5 <5.5 100 0.0026 <7.01 <0.0026
332321874-0006
TUCA1222AS007A 12/22/2023 992.8 <5.5 100 0.0027 <7.01 <0.0027
332321874-0007
TUCA1222AS008A 12/22/2023 Filter was wet
332321874-0008
TUCA1222AS009A 12/22/2023 1058.2 <5.5 100 0.0025 <7.01 <0.0025
332321874-0009
TUCA1222AS010A 12/22/2023 1027.9 <5.5 100 0.0026 <7.01 <0.0026
332321874-0010
TUCA1222AS013A 12/22/2023 863.6 <5.5 100 0.0031 <7.01 <0.0031
332321874-0011
TUCA1222AS014A 12/22/2023 823 <5.5 100 0.0033 <7.01 <0.0033
332321874-0012
TUCA1222AS015A 12/22/2023 1062 <5.5 100 0.0025 <7.01 <0.0025
332321874-0013
TUCA1222AS017A 12/22/2023 1030 <5.5 100 0.0026 <7.01 <0.0026
332321874-0014
TUCA1222AS018A 12/22/2023 1019.3 <5.5 100 0.0026 <7.01 <0.0026
332321874-0015
TUCA1222AS019A 12/22/2023 1092.2 <5.5 100 0.0025 <7.01 <0.0025
332321874-0016
TUCA1222AS021A 12/22/2023 1058 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/23/2023 02:59 PM
Printed: 12/23/2023 02:59 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332321874
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/23/2023 10:45 AM
North Little Rock, AR 72118 Analysis Date:12/23/2023
Collected Date:12/22/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332321874-0017
TUCA1222ASFB001A 12/22/2023 <5.5 100 <7.01 Field Blank
332321874-0018
TUCA1222AS001B 12/22/2023 1170.7 <5.5 100 0.0023 <7.01 <0.0023
332321874-0019
TUCA1222AS002B 12/22/2023 1035.5 <5.5 100 0.0026 <7.01 <0.0026
332321874-0020
TUCA1222AS003B 12/22/2023 1029.3 <5.5 100 0.0026 <7.01 <0.0026
332321874-0021
TUCA1222AS004B 12/22/2023 1021.5 <5.5 100 0.0026 <7.01 <0.0026
332321874-0022
TUCA1222AS005B 12/22/2023 830.6 <5.5 100 0.0032 <7.01 <0.0032
332321874-0023
TUCA1222AS006B 12/22/2023 1004.2 <5.5 100 0.0027 <7.01 <0.0027
332321874-0024
TUCA1222AS008B 12/22/2023 997.2 <5.5 100 0.0027 <7.01 <0.0027
332321874-0025
TUCA1222AS009B 12/22/2023 974.8 <5.5 100 0.0028 <7.01 <0.0028
332321874-0026
TUCA1222AS010B 12/22/2023 921 <5.5 100 0.0029 <7.01 <0.0029
332321874-0027
TUCA1222ASFB001B 12/22/2023 <5.5 100 <7.01 Field Blank
332321874-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Mindy Le PCM 27
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/23/2023 02:59 PM
Printed: 12/23/2023 02:59 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2