HomeMy WebLinkAboutPCM 12232023LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332321909
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/26/2023 11:20 AM
North Little Rock, AR 72118 Analysis Date:12/26/2023
Collected Date:12/23/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1223AS001A 12/23/2023 1496.3 <5.5 100 0.0018 <7.01 <0.0018
332321909-0001
TUCA1223AS002A 12/23/2023 1065.6 <5.5 100 0.0025 <7.01 <0.0025
332321909-0002
TUCA1223AS003A 12/23/2023 1058.5 <5.5 100 0.0025 <7.01 <0.0025
332321909-0003
TUCA1223AS004A 12/23/2023 984.9 <5.5 100 0.0027 <7.01 <0.0027
332321909-0004
TUCA1223AS005A 12/23/2023 1047.2 <5.5 100 0.0026 <7.01 <0.0026
332321909-0005
TUCA1223AS006A 12/23/2023 1051.8 <5.5 100 0.0026 <7.01 <0.0026
332321909-0006
TUCA1223AS007A 12/23/2023 966.5 <5.5 100 0.0028 <7.01 <0.0028
332321909-0007
TUCA1223AS008A 12/23/2023 1072.6 <5.5 100 0.0025 <7.01 <0.0025
332321909-0008
TUCA1223AS009A 12/23/2023 1066 <5.5 100 0.0025 <7.01 <0.0025
332321909-0009
TUCA1223AS010A 12/23/2023 1015.4 <5.5 100 0.0027 <7.01 <0.0027
332321909-0010
TUCA1223AS013A 12/23/2023 905 <5.5 100 0.0030 <7.01 <0.0030
332321909-0011
TUCA1223AS014A 12/23/2023 775 <5.5 100 0.0035 <7.01 <0.0035
332321909-0012
TUCA1223AS015A 12/23/2023 1054.4 <5.5 100 0.0026 <7.01 <0.0026
332321909-0013
TUCA1223AS017A 12/23/2023 967.9 <5.5 100 0.0028 <7.01 <0.0028
332321909-0014
TUCA1223AS018A 12/23/2023 1036 <5.5 100 0.0026 <7.01 <0.0026
332321909-0015
TUCA1223AS019A 12/23/2023 1039.9 <5.5 100 0.0026 <7.01 <0.0026
332321909-0016
TUCA1223AS021A 12/23/2023 1113.6 <5.5 100 0.0024 <7.01 <0.0024
332321909-0017
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/26/2023 05:03 PM
Printed: 12/26/2023 05:04 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332321909
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/26/2023 11:20 AM
North Little Rock, AR 72118 Analysis Date:12/26/2023
Collected Date:12/23/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1223ASFB001A 12/23/2023 <5.5 100 <7.01 Field Blank
332321909-0018
TUCA1223AS001B 12/23/2023 1001.6 <5.5 100 0.0027 <7.01 <0.0027
332321909-0019
TUCA1223AS002B 12/23/2023 1027.4 10 100 0.0026 12.7 0.0048
332321909-0020
TUCA1223AS003B 12/23/2023 1027.9 7.5 100 0.0026 9.55 0.0036
332321909-0021
TUCA1223AS004B 12/23/2023 1016.1 8.5 100 0.0027 10.8 0.0041
332321909-0022
TUCA1223AS005B 12/23/2023 979.6 <5.5 100 0.0028 <7.01 <0.0028
332321909-0023
TUCA1223AS006B 12/23/2023 999.4 <5.5 100 0.0027 <7.01 <0.0027
332321909-0024
TUCA1223AS007B 12/23/2023 991.3 6 100 0.0027 7.64 0.0030
332321909-0025
TUCA1223AS008B 12/23/2023 1005.4 <5.5 100 0.0027 <7.01 <0.0027
332321909-0026
TUCA1223AS009B 12/23/2023 996.4 <5.5 100 0.0027 <7.01 <0.0027
332321909-0027
TUCA1223AS010B 12/23/2023 1002.5 <5.5 100 0.0027 <7.01 <0.0027
332321909-0028
TUCA1223ASFB001B 12/23/2023 <5.5 100 <7.01 Field Blank
332321909-0029
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Christopher Miranda PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/26/2023 05:03 PM
Printed: 12/26/2023 05:04 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2