HomeMy WebLinkAboutPCM 12292023LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332322132
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/30/2023 10:30 AM
North Little Rock, AR 72118 Analysis Date:12/30/2023
Collected Date:12/29/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1229AS001A 12/29/2023 1050.5 8 100 0.0026 10.2 0.0037
332322132-0001
TUCA1229AS002A 12/29/2023 1057.2 <5.5 100 0.0025 <7.01 <0.0025
332322132-0002
TUCA1229AS003A 12/29/2023 1011.4 <5.5 100 0.0027 <7.01 <0.0027
332322132-0003
TUCA1229AS004A 12/29/2023 1022.3 <5.5 100 0.0026 <7.01 <0.0026
332322132-0004
TUCA1229AS005A 12/29/2023 1042.9 <5.5 100 0.0026 <7.01 <0.0026
332322132-0005
TUCA1229AS006A 12/29/2023 1052.5 <5.5 100 0.0026 <7.01 <0.0026
332322132-0006
TUCA1229AS007A 12/29/2023 971.7 <5.5 100 0.0028 <7.01 <0.0028
332322132-0007
TUCA1229AS008A 12/29/2023 1084.6 <5.5 100 0.0025 <7.01 <0.0025
332322132-0008
TUCA1229AS009A 12/29/2023 1061.9 <5.5 100 0.0025 <7.01 <0.0025
332322132-0009
TUCA1229AS010A 12/29/2023 1014.1 <5.5 100 0.0027 <7.01 <0.0027
332322132-0010
TUCA1229AS013A 12/29/2023 889.7 <5.5 100 0.0030 <7.01 <0.0030
332322132-0011
TUCA1229AS015A 12/29/2023 1051.3 <5.5 100 0.0026 <7.01 <0.0026
332322132-0012
TUCA1229AS017A 12/29/2023 992.2 <5.5 100 0.0027 <7.01 <0.0027
332322132-0013
TUCA1229AS018A 12/29/2023 997.4 <5.5 100 0.0027 <7.01 <0.0027
332322132-0014
TUCA1229AS019A 12/29/2023 1054.7 <5.5 100 0.0026 <7.01 <0.0026
332322132-0015
TUCA1229AS021A 12/29/2023 1037.4 <5.5 100 0.0026 <7.01 <0.0026
332322132-0016
TUCA1229ASFB001A 12/29/2023 <5.5 100 <7.01 Field Blank
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/30/2023 02:36 PM
Printed: 12/30/2023 02:36 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332322132
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:12/30/2023 10:30 AM
North Little Rock, AR 72118 Analysis Date:12/30/2023
Collected Date:12/29/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332322132-0017
TUCA1229AS001B 12/29/2023 989.3 <5.5 100 0.0027 <7.01 <0.0027
332322132-0018
TUCA1229AS002B 12/29/2023 1024.3 <5.5 100 0.0026 <7.01 <0.0026
332322132-0019
TUCA1229AS003B 12/29/2023 1016.5 <5.5 100 0.0027 <7.01 <0.0027
332322132-0020
TUCA1229AS004B 12/29/2023 1008 <5.5 100 0.0027 <7.01 <0.0027
332322132-0021
TUCA1229AS005B 12/29/2023 987.9 <5.5 100 0.0027 <7.01 <0.0027
332322132-0022
TUCA1229AS006B 12/29/2023 989.9 <5.5 100 0.0027 <7.01 <0.0027
332322132-0023
TUCA1229AS007B 12/29/2023 998.1 19 100 0.0027 24.2 0.0093
332322132-0024
TUCA1229AS008B 12/29/2023 985 <5.5 100 0.0027 <7.01 <0.0027
332322132-0025
TUCA1229AS009B 12/29/2023 963.5 <5.5 100 0.0028 <7.01 <0.0028
332322132-0026
TUCA1229AS010B 12/29/2023 925.9 <5.5 100 0.0029 <7.01 <0.0029
332322132-0027
TUCA1229ASFB001B 12/29/2023 <5.5 100 <7.01 Field Blank
332322132-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Mindy Le PCM 28
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 12/30/2023 02:36 PM
Printed: 12/30/2023 02:36 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2