HomeMy WebLinkAboutPCM 12312023LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400010
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/02/2024 10:35 AM
North Little Rock, AR 72118 Analysis Date:01/02/2024
Collected Date:12/31/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1231AS001A 12/31/2023 948.1 <5.5 100 0.0028 <7.01 <0.0028
332400010-0001
TUCA1231AS002A 12/31/2023 1073.2 <5.5 100 0.0025 <7.01 <0.0025
332400010-0002
TUCA1231AS003A 12/31/2023 1043.6 <5.5 100 0.0026 <7.01 <0.0026
332400010-0003
TUCA1231AS004A 12/31/2023 1031.3 <5.5 100 0.0026 <7.01 <0.0026
332400010-0004
TUCA1231AS005A 12/31/2023 1029.9 <5.5 100 0.0026 <7.01 <0.0026
332400010-0005
TUCA1231AS006A 12/31/2023 1042.9 <5.5 100 0.0026 <7.01 <0.0026
332400010-0006
TUCA1231AS007A 12/31/2023 973.8 <5.5 100 0.0028 <7.01 <0.0028
332400010-0007
TUCA1231AS008A 12/31/2023 1074.3 <5.5 100 0.0025 <7.01 <0.0025
332400010-0008
TUCA1231AS009A 12/31/2023 1059.8 <5.5 100 0.0025 <7.01 <0.0025
332400010-0009
TUCA1231AS010A 12/31/2023 1022 <5.5 100 0.0026 <7.01 <0.0026
332400010-0010
TUCA1231AS013A 12/31/2023 865.8 <5.5 100 0.0031 <7.01 <0.0031
332400010-0011
TUCA1231AS014A 12/31/2023 732 <5.5 100 0.0037 <7.01 <0.0037
332400010-0012
TUCA1231AS015A 12/31/2023 1038 <5.5 100 0.0026 <7.01 <0.0026
332400010-0013
TUCA1231AS017A 12/31/2023 1062.3 <5.5 100 0.0025 <7.01 <0.0025
332400010-0014
TUCA1231AS018A 12/31/2023 970.8 <5.5 100 0.0028 <7.01 <0.0028
332400010-0015
TUCA1231AS019A 12/31/2023 1034.4 <5.5 100 0.0026 <7.01 <0.0026
332400010-0016
TUCA1231AS021A 12/31/2023 716 <5.5 100 0.0038 <7.01 <0.0038
332400010-0017
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/02/2024 04:31 PM
Printed: 01/02/2024 04:31 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400010
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/02/2024 10:35 AM
North Little Rock, AR 72118 Analysis Date:01/02/2024
Collected Date:12/31/2023
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA1231ASFB001A 12/31/2023 <5.5 100 <7.01 Field Blank
332400010-0018
TUCA1231AS001B 12/31/2023 1012.8 <5.5 100 0.0027 <7.01 <0.0027
332400010-0019
TUCA1231AS002B 12/31/2023 1065.2 <5.5 100 0.0025 <7.01 <0.0025
332400010-0020
TUCA1231AS003B 12/31/2023 1069.5 <5.5 100 0.0025 <7.01 <0.0025
332400010-0021
TUCA1231AS004B 12/31/2023 1034.8 <5.5 100 0.0026 <7.01 <0.0026
332400010-0022
TUCA1231AS005B 12/31/2023 1011 <5.5 100 0.0027 <7.01 <0.0027
332400010-0023
TUCA1231AS006B 12/31/2023 1029.3 <5.5 100 0.0026 <7.01 <0.0026
332400010-0024
TUCA1231AS007B 12/31/2023 1045.6 <5.5 100 0.0026 <7.01 <0.0026
332400010-0025
TUCA1231AS008B 12/31/2023 1007.3 <5.5 100 0.0027 <7.01 <0.0027
332400010-0026
TUCA1231AS009B 12/31/2023 1021.1 <5.5 100 0.0026 <7.01 <0.0026
332400010-0027
TUCA1231AS010B 12/31/2023 917.3 <5.5 100 0.0029 <7.01 <0.0029
332400010-0028
TUCA1231ASFB001B 12/31/2023 <5.5 100 <7.01 Field Blank
332400010-0029
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Christopher Miranda PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/02/2024 04:31 PM
Printed: 01/02/2024 04:31 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2