HomeMy WebLinkAboutPCM 01012024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400012
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/02/2024 10:35 AM
North Little Rock, AR 72118 Analysis Date:01/02/2024
Collected Date:01/01/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0101AS001A 01/01/2024 1121.5 <5.5 100 0.0024 <7.01 <0.0024
332400012-0001
TUCA0101AS002A 01/01/2024 1076.1 <5.5 100 0.0025 <7.01 <0.0025
332400012-0002
TUCA0101AS003A 01/01/2024 1063.7 <5.5 100 0.0025 <7.01 <0.0025
332400012-0003
TUCA0101AS004A 01/01/2024 1070.4 <5.5 100 0.0025 <7.01 <0.0025
332400012-0004
TUCA0101AS005A 01/01/2024 1050.5 <5.5 100 0.0026 <7.01 <0.0026
332400012-0005
TUCA0101AS006A 01/01/2024 1064.3 <5.5 100 0.0025 <7.01 <0.0025
332400012-0006
TUCA0101AS007A 01/01/2024 986.2 <5.5 100 0.0027 <7.01 <0.0027
332400012-0007
TUCA0101AS008A 01/01/2024 1080.3 <5.5 100 0.0025 <7.01 <0.0025
332400012-0008
TUCA0101AS009A 01/01/2024 1075.9 <5.5 100 0.0025 <7.01 <0.0025
332400012-0009
TUCA0101AS010A 01/01/2024 1043.1 <5.5 100 0.0026 <7.01 <0.0026
332400012-0010
TUCA0101AS013A 01/01/2024 1064.9 <5.5 100 0.0025 <7.01 <0.0025
332400012-0011
TUCA0101AS014A 01/01/2024 939.5 <5.5 100 0.0029 <7.01 <0.0029
332400012-0012
TUCA0101AS015A 01/01/2024 1058.3 <5.5 100 0.0025 <7.01 <0.0025
332400012-0013
TUCA0101AS017A 01/01/2024 981.4 <5.5 100 0.0027 <7.01 <0.0027
332400012-0014
TUCA0101AS018A 01/01/2024 996.1 <5.5 100 0.0027 <7.01 <0.0027
332400012-0015
TUCA0101AS019A 01/01/2024 1064.5 <5.5 100 0.0025 <7.01 <0.0025
332400012-0016
TUCA0101AS021A 01/01/2024 1057.2 <5.5 100 0.0025 <7.01 <0.0025
332400012-0017
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/02/2024 04:53 PM
Printed: 01/02/2024 04:53 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400012
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/02/2024 10:35 AM
North Little Rock, AR 72118 Analysis Date:01/02/2024
Collected Date:01/01/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0101ASFB001A 01/01/2024 <5.5 100 <7.01 Field Blank
332400012-0018
TUCA0101AS001B 01/01/2024 1005.8 <5.5 100 0.0027 <7.01 <0.0027
332400012-0019
TUCA0101AS002B 01/01/2024 1008.7 <5.5 100 0.0027 <7.01 <0.0027
332400012-0020
TUCA0101AS003B 01/01/2024 1000.5 <5.5 100 0.0027 <7.01 <0.0027
332400012-0021
TUCA0101AS004B 01/01/2024 987.4 <5.5 100 0.0027 <7.01 <0.0027
332400012-0022
TUCA0101AS005B 01/01/2024 958.9 <5.5 100 0.0028 <7.01 <0.0028
332400012-0023
TUCA0101AS006B 01/01/2024 957.9 <5.5 100 0.0028 <7.01 <0.0028
332400012-0024
TUCA0101AS007B 01/01/2024 964.8 <5.5 100 0.0028 <7.01 <0.0028
332400012-0025
TUCA0101AS008B 01/01/2024 945.8 <5.5 100 0.0028 <7.01 <0.0028
332400012-0026
TUCA0101AS009B 01/01/2024 924.6 <5.5 100 0.0029 <7.01 <0.0029
332400012-0027
TUCA0101AS010B 01/01/2024 916.2 <5.5 100 0.0029 <7.01 <0.0029
332400012-0028
TUCA0101ASFB001B 01/01/2024 <5.5 100 <7.01 Field Blank
332400012-0029
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Christopher Miranda PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/02/2024 04:53 PM
Printed: 01/02/2024 04:53 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2