Loading...
HomeMy WebLinkAboutPCM 01022024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332400080 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:01/03/2024 09:30 AM North Little Rock, AR 72118 Analysis Date:01/03/2024 Collected Date:01/02/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/15/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0102AS001A 01/02/2024 1066.7 <5.5 100 0.0025 <7.01 <0.0025 332400080-0001 TUCA0102AS002A 01/02/2024 1076.2 <5.5 100 0.0025 <7.01 <0.0025 332400080-0002 TUCA0102AS003A 01/02/2024 1028.3 <5.5 100 0.0026 <7.01 <0.0026 332400080-0003 TUCA0102AS004A 01/02/2024 1037.7 <5.5 100 0.0026 <7.01 <0.0026 332400080-0004 TUCA0102AS005A 01/02/2024 1035.5 <5.5 100 0.0026 <7.01 <0.0026 332400080-0005 TUCA0102AS006A 01/02/2024 1030.5 <5.5 100 0.0026 <7.01 <0.0026 332400080-0006 TUCA0102AS007A 01/02/2024 955.7 <5.5 100 0.0028 <7.01 <0.0028 332400080-0007 TUCA0102AS008A 01/02/2024 1079.4 <5.5 100 0.0025 <7.01 <0.0025 332400080-0008 TUCA0102AS009A 01/02/2024 1077.5 <5.5 100 0.0025 <7.01 <0.0025 332400080-0009 TUCA0102AS010A 01/02/2024 1017.5 <5.5 100 0.0026 <7.01 <0.0026 332400080-0010 TUCA0102AS013A 01/02/2024 1008.6 <5.5 100 0.0027 <7.01 <0.0027 332400080-0011 TUCA0102AS014A 01/02/2024 902.9 <5.5 100 0.0030 <7.01 <0.0030 332400080-0012 TUCA0102AS015A 01/02/2024 1019 <5.5 100 0.0026 <7.01 <0.0026 332400080-0013 TUCA0102AS017A 01/02/2024 966.9 <5.5 100 0.0028 <7.01 <0.0028 332400080-0014 TUCA0102AS018A 01/02/2024 981.6 <5.5 100 0.0027 <7.01 <0.0027 332400080-0015 TUCA0102AS019A 01/02/2024 1059.5 <5.5 100 0.0025 <7.01 <0.0025 332400080-0016 TUCA0102AS021A 01/02/2024 999.1 <5.5 100 0.0027 <7.01 <0.0027 332400080-0017 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 01/03/2024 03:04 PM Printed: 01/03/2024 03:04 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332400080 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:01/03/2024 09:30 AM North Little Rock, AR 72118 Analysis Date:01/03/2024 Collected Date:01/02/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/15/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0102ASFB001A 01/02/2024 <5.5 100 <7.01 Field Blank 332400080-0018 TUCA0102AS001B 01/02/2024 1014.7 <5.5 100 0.0027 <7.01 <0.0027 332400080-0019 TUCA0102AS002B 01/02/2024 1023 <5.5 100 0.0026 <7.01 <0.0026 332400080-0020 TUCA0102AS003B 01/02/2024 1019.2 <5.5 100 0.0026 <7.01 <0.0026 332400080-0021 TUCA0102AS004B 01/02/2024 1010.1 <5.5 100 0.0027 <7.01 <0.0027 332400080-0022 TUCA0102AS005B 01/02/2024 990.2 <5.5 100 0.0027 <7.01 <0.0027 332400080-0023 TUCA0102AS006B 01/02/2024 979.5 <5.5 100 0.0028 <7.01 <0.0028 332400080-0024 TUCA0102AS007B 01/02/2024 1007.6 <5.5 100 0.0027 <7.01 <0.0027 332400080-0025 TUCA0102AS008B 01/02/2024 996 <5.5 100 0.0027 <7.01 <0.0027 332400080-0026 TUCA0102AS009B 01/02/2024 975.1 <5.5 100 0.0028 <7.01 <0.0028 332400080-0027 TUCA0102AS010B 01/02/2024 941.8 <5.5 100 0.0029 <7.01 <0.0029 332400080-0028 TUCA0102ASFB001B 01/02/2024 <5.5 100 <7.01 Field Blank 332400080-0029 The results reported have been blank corrected as applicable. Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Christopher Miranda PCM 29 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 01/03/2024 03:04 PM Printed: 01/03/2024 03:04 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2