HomeMy WebLinkAboutPCM 01062024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400277
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/08/2024 10:25 AM
North Little Rock, AR 72118 Analysis Date:01/08/2024
Collected Date:01/06/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0106AS001A 01/06/2024 1021.1 <5.5 100 0.0026 <7.01 <0.0026
332400277-0001
TUCA0106AS002A 01/06/2024 1028.9 <5.5 100 0.0026 <7.01 <0.0026
332400277-0002
TUCA0106AS003A 01/06/2024 1140 <5.5 100 0.0024 <7.01 <0.0024
332400277-0003
TUCA0106AS004A 01/06/2024 1026.6 <5.5 100 0.0026 <7.01 <0.0026
332400277-0004
TUCA0106AS005A 01/06/2024 1068.5 <5.5 100 0.0025 <7.01 <0.0025
332400277-0005
TUCA0106AS006A 01/06/2024 1047.1 <5.5 100 0.0026 <7.01 <0.0026
332400277-0006
TUCA0106AS007A 01/06/2024 985.8 <5.5 100 0.0027 <7.01 <0.0027
332400277-0007
TUCA0106AS008A 01/06/2024 1054.9 8 100 0.0026 10.2 0.0037
332400277-0008
TUCA0106AS009A 01/06/2024 1078.8 <5.5 100 0.0025 <7.01 <0.0025
332400277-0009
TUCA0106AS010A 01/06/2024 1023.2 <5.5 100 0.0026 <7.01 <0.0026
332400277-0010
TUCA0106AS013A 01/06/2024 1019.9 <5.5 100 0.0026 <7.01 <0.0026
332400277-0011
TUCA0106AS014A 01/06/2024 882.5 <5.5 100 0.0031 <7.01 <0.0031
332400277-0012
TUCA0106AS015A 01/06/2024 955.5 <5.5 100 0.0028 <7.01 <0.0028
332400277-0013
TUCA0106AS017A 01/06/2024 956.6 <5.5 100 0.0028 <7.01 <0.0028
332400277-0014
TUCA0106AS018A 01/06/2024 888.9 <5.5 100 0.0030 <7.01 <0.0030
332400277-0015
TUCA0106AS019A 01/06/2024 988.1 <5.5 100 0.0027 <7.01 <0.0027
332400277-0016
TUCA0106AS021A 01/06/2024 949.1 <5.5 100 0.0028 <7.01 <0.0028
332400277-0017
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/08/2024 12:37 PM
Printed: 01/08/2024 12:37 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400277
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/08/2024 10:25 AM
North Little Rock, AR 72118 Analysis Date:01/08/2024
Collected Date:01/06/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0106ASFB001A 01/06/2024 <5.5 100 <7.01 Field Blank
332400277-0018
TUCA0106AS002B 01/06/2024 1049.3 <5.5 100 0.0026 <7.01 <0.0026
332400277-0019
TUCA0106AS003B 01/06/2024 1042.4 <5.5 100 0.0026 <7.01 <0.0026
332400277-0020
TUCA0106AS004B 01/06/2024 1038.7 <5.5 100 0.0026 <7.01 <0.0026
332400277-0021
TUCA0106AS005B 01/06/2024 1019.7 <5.5 100 0.0026 <7.01 <0.0026
332400277-0022
TUCA0106AS006B 01/06/2024 952.3 <5.5 100 0.0028 <7.01 <0.0028
332400277-0023
TUCA0106AS007B 01/06/2024 1029.2 <5.5 100 0.0026 <7.01 <0.0026
332400277-0024
TUCA0106AS008B 01/06/2024 945.7 <5.5 100 0.0028 <7.01 <0.0028
332400277-0025
TUCA0106AS009B 01/06/2024 1004.6 <5.5 100 0.0027 <7.01 <0.0027
332400277-0026
TUCA0106AS010B 01/06/2024 953.6 <5.5 100 0.0028 <7.01 <0.0028
332400277-0027
TUCA0106ASFB001B 01/06/2024 <5.5 100 <7.01 Field Blank
332400277-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Christopher Miranda PCM 28
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/08/2024 12:37 PM
Printed: 01/08/2024 12:37 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2