HomeMy WebLinkAboutPCM 01072024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400278
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/08/2024 10:25 AM
North Little Rock, AR 72118 Analysis Date:01/08/2024
Collected Date:01/07/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0107AS001A 01/07/2024 1047.9 <5.5 100 0.0026 <7.01 <0.0026
332400278-0001
TUCA0107AS002A 01/07/2024 1076.2 <5.5 100 0.0025 <7.01 <0.0025
332400278-0002
TUCA0107AS003A 01/07/2024 1032.5 <5.5 100 0.0026 <7.01 <0.0026
332400278-0003
TUCA0107AS004A 01/07/2024 1023.5 <5.5 100 0.0026 <7.01 <0.0026
332400278-0004
TUCA0107AS007A 01/07/2024 938.2 <5.5 100 0.0029 <7.01 <0.0029
332400278-0005
TUCA0107AS008A 01/07/2024 1039.6 <5.5 100 0.0026 <7.01 <0.0026
332400278-0006
TUCA0107AS009A 01/07/2024 950.2 <5.5 100 0.0028 <7.01 <0.0028
332400278-0007
TUCA0107AS010A 01/07/2024 1080.1 <5.5 100 0.0025 <7.01 <0.0025
332400278-0008
TUCA0107AS013A 01/07/2024 1034.8 <5.5 100 0.0026 <7.01 <0.0026
332400278-0009
TUCA0107AS014A 01/07/2024 909.6 <5.5 100 0.0030 <7.01 <0.0030
332400278-0010
TUCA0107AS015A 01/07/2024 1051.9 <5.5 100 0.0026 <7.01 <0.0026
332400278-0011
TUCA0107AS017A 01/07/2024 951.2 <5.5 100 0.0028 <7.01 <0.0028
332400278-0012
TUCA0107AS018A 01/07/2024 977.7 <5.5 100 0.0028 <7.01 <0.0028
332400278-0013
TUCA0107AS019A 01/07/2024 1043.9 <5.5 100 0.0026 <7.01 <0.0026
332400278-0014
TUCA0107AS021A 01/07/2024 1019.2 <5.5 100 0.0026 <7.01 <0.0026
332400278-0015
TUCA0107ASFB001A 01/07/2024 <5.5 100 <7.01 Field Blank
332400278-0016
TUCA0107AS001B 01/07/2024 1025.8 <5.5 100 0.0026 <7.01 <0.0026
332400278-0017
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/08/2024 02:43 PM
Printed: 01/08/2024 02:43 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400278
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/08/2024 10:25 AM
North Little Rock, AR 72118 Analysis Date:01/08/2024
Collected Date:01/07/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0107AS002B 01/07/2024 992.3 <5.5 100 0.0027 <7.01 <0.0027
332400278-0018
TUCA0107AS003B 01/07/2024 1077.4 <5.5 100 0.0025 <7.01 <0.0025
332400278-0019
TUCA0107AS004B 01/07/2024 1078 <5.5 100 0.0025 <7.01 <0.0025
332400278-0020
TUCA0107AS005B 01/07/2024 1053.8 <5.5 100 0.0026 <7.01 <0.0026
332400278-0021
TUCA0107AS006B 01/07/2024 914.3 <5.5 100 0.0029 <7.01 <0.0029
332400278-0022
TUCA0107AS007B 01/07/2024 1059.6 <5.5 100 0.0025 <7.01 <0.0025
332400278-0023
TUCA0107AS008B 01/07/2024 933.7 <5.5 100 0.0029 <7.01 <0.0029
332400278-0024
TUCA0107AS009B 01/07/2024 1025.7 <5.5 100 0.0026 <7.01 <0.0026
332400278-0025
TUCA0107AS010B 01/07/2024 939.4 <5.5 100 0.0029 <7.01 <0.0029
332400278-0026
TUCA0107ASFB001B 01/07/2024 <5.5 100 <7.01 Field Blank
332400278-0027
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Christopher Miranda PCM 27
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/08/2024 02:43 PM
Printed: 01/08/2024 02:43 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2