HomeMy WebLinkAboutPCM 01092024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400422
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/10/2024 09:30 AM
North Little Rock, AR 72118 Analysis Date:01/10/2024
Collected Date:01/09/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0109AS001A 01/09/2024 1037.1 <5.5 100 0.0026 <7.01 <0.0026
332400422-0001
TUCA0109AS002A 01/09/2024 1090.4 <5.5 100 0.0025 <7.01 <0.0025
332400422-0002
TUCA0109AS003A 01/09/2024 674.3 <5.5 100 0.0040 <7.01 <0.0040
332400422-0003
TUCA0109AS004A 01/09/2024 1014.9 <5.5 100 0.0027 <7.01 <0.0027
332400422-0004
TUCA0109AS005A 01/09/2024 1083.4 <5.5 100 0.0025 <7.01 <0.0025
332400422-0005
TUCA0109AS006A 01/09/2024 1054.7 <5.5 100 0.0026 <7.01 <0.0026
332400422-0006
TUCA0109AS007A 01/09/2024 916.2 <5.5 100 0.0029 <7.01 <0.0029
332400422-0007
TUCA0109AS008A 01/09/2024 1081.4 <5.5 100 0.0025 <7.01 <0.0025
332400422-0008
TUCA0109AS009A 01/09/2024 1078.3 <5.5 100 0.0025 <7.01 <0.0025
332400422-0009
TUCA0109AS010A 01/09/2024 1004.4 <5.5 100 0.0027 <7.01 <0.0027
332400422-0010
TUCA0109AS013A 01/09/2024 939.8 <5.5 100 0.0029 <7.01 <0.0029
332400422-0011
TUCA0109AS014A 01/09/2024 908.1 <5.5 100 0.0030 <7.01 <0.0030
332400422-0012
TUCA0109AS015A 01/09/2024 1065.3 <5.5 100 0.0025 <7.01 <0.0025
332400422-0013
TUCA0109AS017A 01/09/2024 947.3 <5.5 100 0.0028 <7.01 <0.0028
332400422-0014
TUCA0109AS018A 01/09/2024 964.4 <5.5 100 0.0028 <7.01 <0.0028
332400422-0015
TUCA0109AS019A 01/09/2024 1036 <5.5 100 0.0026 <7.01 <0.0026
332400422-0016
TUCA0109AS021A 01/09/2024 976.4 <5.5 100 0.0028 <7.01 <0.0028
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/10/2024 02:21 PM
Printed: 01/10/2024 02:21 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400422
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/10/2024 09:30 AM
North Little Rock, AR 72118 Analysis Date:01/10/2024
Collected Date:01/09/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332400422-0017
TUCA0109ASFB001A 01/09/2024 <5.5 100 <7.01 Field Blank
332400422-0018
TUCA0109AS001B 01/09/2024 993.7 <5.5 100 0.0027 <7.01 <0.0027
332400422-0019
TUCA0109AS002B 01/09/2024 1067.2 <5.5 100 0.0025 <7.01 <0.0025
332400422-0020
TUCA0109AS003B 01/09/2024 1032.5 <5.5 100 0.0026 <7.01 <0.0026
332400422-0021
TUCA0109AS004B 01/09/2024 1023.4 <5.5 100 0.0026 <7.01 <0.0026
332400422-0022
TUCA0109AS005B 01/09/2024 1042.3 <5.5 100 0.0026 <7.01 <0.0026
332400422-0023
TUCA0109AS006B 01/09/2024 785.5 <5.5 100 0.0034 <7.01 <0.0034
332400422-0024
TUCA0109AS007B 01/09/2024 960.6 <5.5 100 0.0028 <7.01 <0.0028
332400422-0025
TUCA0109AS008B 01/09/2024 905.1 <5.5 100 0.0030 <7.01 <0.0030
332400422-0026
TUCA0109AS009B 01/09/2024 849.1 <5.5 100 0.0032 <7.01 <0.0032
332400422-0027
TUCA0109AS010B 01/09/2024 942.5 <5.5 100 0.0029 <7.01 <0.0029
332400422-0028
TUCA0109ASFB001B 01/09/2024 <5.5 100 <7.01 Field Blank
332400422-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/10/2024 02:21 PM
Printed: 01/10/2024 02:21 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400422
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/10/2024 09:30 AM
North Little Rock, AR 72118 Analysis Date:01/10/2024
Collected Date:01/09/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/10/2024 02:21 PM
Printed: 01/10/2024 02:21 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3