LA Testing Order:332400590
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/12/2024 09:45 AM
North Little Rock, AR 72118 Analysis Date:01/12/2024
Collected Date:01/11/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0111AS001A 01/11/2024 1077.6 <5.5 100 0.0025 <7.01 <0.0025
332400590-0001
TUCA0111AS002A 01/11/2024 1091.3 <5.5 100 0.0025 <7.01 <0.0025
332400590-0002
TUCA0111AS003A 01/11/2024 1052.9 <5.5 100 0.0026 <7.01 <0.0026
332400590-0003
TUCA0111AS004A 01/11/2024 1068.2 <5.5 100 0.0025 <7.01 <0.0025
332400590-0004
TUCA0111AS005A 01/11/2024 1065.2 <5.5 100 0.0025 <7.01 <0.0025
332400590-0005
TUCA0111AS006A 01/11/2024 1063.1 <5.5 100 0.0025 <7.01 <0.0025
332400590-0006
TUCA0111AS007A 01/11/2024 994.1 <5.5 100 0.0027 <7.01 <0.0027
332400590-0007
TUCA0111AS008A 01/11/2024 1104.6 <5.5 100 0.0024 <7.01 <0.0024
332400590-0008
TUCA0111AS009A 01/11/2024 787.8 <5.5 100 0.0034 <7.01 <0.0034
332400590-0009
TUCA0111AS010A 01/11/2024 1055.2 <5.5 100 0.0026 <7.01 <0.0026
332400590-0010
TUCA0111AS013A 01/11/2024 1035.8 <5.5 100 0.0026 <7.01 <0.0026
332400590-0011
TUCA0111AS014A 01/11/2024 850.9 <5.5 100 0.0032 <7.01 <0.0032
332400590-0012
TUCA0111AS015A 01/11/2024 1072.2 <5.5 100 0.0025 <7.01 <0.0025
332400590-0013
TUCA0111AS017A 01/11/2024 958.1 <5.5 100 0.0028 <7.01 <0.0028
332400590-0014
TUCA0111AS018A 01/11/2024 979.7 <5.5 100 0.0028 <7.01 <0.0028
332400590-0015
TUCA0111AS019A 01/11/2024 1070.1 <5.5 100 0.0025 <7.01 <0.0025
332400590-0016
TUCA0111AS021A 01/11/2024 984.9 <5.5 100 0.0027 <7.01 <0.0027
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/12/2024 01:41 PM
Printed: 01/12/2024 01:41 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400590
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/12/2024 09:45 AM
North Little Rock, AR 72118 Analysis Date:01/12/2024
Collected Date:01/11/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332400590-0017
TUCA0111ASFB001A 01/11/2024 <5.5 100 <7.01 Field Blank
332400590-0018
TUCA0111AS001B 01/11/2024 1078.9 <5.5 100 0.0025 <7.01 <0.0025
332400590-0019
TUCA0111AS002B 01/11/2024 1064.3 <5.5 100 0.0025 <7.01 <0.0025
332400590-0020
TUCA0111AS003B 01/11/2024 1085.4 <5.5 100 0.0025 <7.01 <0.0025
332400590-0021
TUCA0111AS004B 01/11/2024 1045.3 <5.5 100 0.0026 <7.01 <0.0026
332400590-0022
TUCA0111AS005B 01/11/2024 1060.5 <5.5 100 0.0025 <7.01 <0.0025
332400590-0023
TUCA0111AS006B 01/11/2024 931.6 <5.5 100 0.0029 <7.01 <0.0029
332400590-0024
TUCA0111AS007B 01/11/2024 1071.3 <5.5 100 0.0025 <7.01 <0.0025
332400590-0025
TUCA0111AS008B 01/11/2024 1032.7 <5.5 100 0.0026 <7.01 <0.0026
332400590-0026
TUCA0111AS009B 01/11/2024 1018.1 <5.5 100 0.0026 <7.01 <0.0026
332400590-0027
TUCA0111AS010B 01/11/2024 925.9 <5.5 100 0.0029 <7.01 <0.0029
332400590-0028
TUCA0111ASFB001B 01/11/2024 <5.5 100 <7.01 Field Blank
332400590-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/12/2024 01:41 PM
Printed: 01/12/2024 01:41 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400590
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/12/2024 09:45 AM
North Little Rock, AR 72118 Analysis Date:01/12/2024
Collected Date:01/11/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Kaylin Luciani PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/12/2024 01:41 PM
Printed: 01/12/2024 01:41 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3