Loading...
HomeMy WebLinkAboutPCM 01132024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332400681 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:01/15/2024 09:55 AM North Little Rock, AR 72118 Analysis Date:01/15/2024 Collected Date:01/13/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/15/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0113AS001A 01/13/2024 1060.2 <5.5 100 0.0025 <7.01 <0.0025 332400681-0001 TUCA0113AS002A 01/13/2024 1030.6 <5.5 100 0.0026 <7.01 <0.0026 332400681-0002 TUCA0113AS003A 01/13/2024 1090.9 <5.5 100 0.0026 <7.01 <0.0026 332400681-0003 TUCA0113AS004A 01/13/2024 923.3 <5.5 100 0.0029 <7.01 <0.0029 332400681-0004 TUCA0113AS005A 01/13/2024 1065.7 <5.5 100 0.0025 <7.01 <0.0025 332400681-0005 TUCA0113AS006A 01/13/2024 844.4 <5.5 100 0.0032 <7.01 <0.0032 332400681-0006 TUCA0113AS007A 01/13/2024 792.6 <5.5 100 0.0034 <7.01 <0.0034 332400681-0007 TUCA0113AS008A 01/13/2024 877.6 <5.5 100 0.0031 <7.01 <0.0031 332400681-0008 TUCA0113AS009A 01/13/2024 907.5 <5.5 100 0.0030 <7.01 <0.0030 332400681-0009 TUCA0113AS010A 01/13/2024 1018.6 <5.5 100 0.0026 <7.01 <0.0026 332400681-0010 TUCA0113AS013A 01/13/2024 1064.6 <5.5 100 0.0025 <7.01 <0.0025 332400681-0011 TUCA0113AS014A 01/13/2024 800.3 <5.5 100 0.0034 <7.01 <0.0034 332400681-0012 TUCA0113AS017A 01/13/2024 979.7 <5.5 100 0.0028 <7.01 <0.0028 332400681-0013 TUCA0113AS018A 01/13/2024 979.8 <5.5 100 0.0028 <7.01 <0.0028 332400681-0014 TUCA0113AS019A 01/13/2024 1087.3 <5.5 100 0.0025 <7.01 <0.0025 332400681-0015 TUCA0113AS021A 01/13/2024 573.7 <5.5 100 0.0047 <7.01 <0.0047 332400681-0016 TUCA0113ASFB001A 01/13/2024 <5.5 100 <7.01 Field Blank LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 01/15/2024 03:00 PM Printed: 01/15/2024 03:00 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332400681 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:01/15/2024 09:55 AM North Little Rock, AR 72118 Analysis Date:01/15/2024 Collected Date:01/13/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/15/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332400681-0017 TUCA0113AS001B 01/13/2024 1029 <5.5 100 0.0026 <7.01 <0.0026 332400681-0018 TUCA0113AS002B 01/13/2024 1068.6 <5.5 100 0.0025 <7.01 <0.0025 332400681-0019 TUCA0113AS003B 01/13/2024 1062.6 <5.5 100 0.0025 <7.01 <0.0025 332400681-0020 TUCA0113AS004B 01/13/2024 1046.2 <5.5 100 0.0026 <7.01 <0.0026 332400681-0021 TUCA0113AS005B 01/13/2024 1011.1 <5.5 100 0.0027 <7.01 <0.0027 332400681-0022 TUCA0113AS006B 01/13/2024 948.5 <5.5 100 0.0028 <7.01 <0.0028 332400681-0023 TUCA0113AS007B 01/13/2024 1007.7 <5.5 100 0.0027 <7.01 <0.0027 332400681-0024 TUCA0113AS008B 01/13/2024 1038.3 <5.5 100 0.0026 <7.01 <0.0026 332400681-0025 TUCA0113AS009B 01/13/2024 1021.4 <5.5 100 0.0026 <7.01 <0.0026 332400681-0026 TUCA0113AS010B 01/13/2024 933.1 <5.5 100 0.0029 <7.01 <0.0029 332400681-0027 TUCA0113ASFB001B 01/13/2024 <5.5 100 <7.01 Field Blank 332400681-0028 The results reported have been blank corrected as applicable. Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Thanh Nguyen PCM 28 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 01/15/2024 03:00 PM Printed: 01/15/2024 03:00 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2