Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0114AS001A 01/14/2024 1020.1 <5.5 100 0.0026 <7.01 <0.0026
332400676-0001
TUCA0114AS002A 01/14/2024 924.5 <5.5 100 0.0029 <7.01 <0.0029
332400676-0002
TUCA0114AS003A 01/14/2024 1027.7 <5.5 100 0.0026 <7.01 <0.0026
332400676-0003
TUCA0114AS004A 01/14/2024 871.8 <5.5 100 0.0031 <7.01 <0.0031
332400676-0004
TUCA0114AS005A 01/14/2024 986.4 <5.5 100 0.0027 <7.01 <0.0027
332400676-0005
TUCA0114AS006A 01/14/2024 1049.3 <5.5 100 0.0026 <7.01 <0.0026
332400676-0006
TUCA0114AS007A 01/14/2024 943.5 <5.5 100 0.0029 <7.01 <0.0029
332400676-0007
TUCA0114AS008A 01/14/2024 1022.3 <5.5 100 0.0026 <7.01 <0.0026
332400676-0008
TUCA0114AS009A 01/14/2024 1069.2 <5.5 100 0.0025 <7.01 <0.0025
332400676-0009
TUCA0114AS010A 01/14/2024 1010.2 <5.5 100 0.0027 <7.01 <0.0027
332400676-0010
TUCA0114AS013A 01/14/2024 1015.7 <5.5 100 0.0027 <7.01 <0.0027
332400676-0011
TUCA0114AS014A 01/14/2024 806.1 <5.5 100 0.0033 <7.01 <0.0033
332400676-0012
TUCA0114AS015A 01/14/2024 1082 <5.5 100 0.0025 <7.01 <0.0025
332400676-0013
TUCA0114AS017A 01/14/2024 976.1 <5.5 100 0.0028 <7.01 <0.0028
332400676-0014
TUCA0114AS018A 01/14/2024 544.2 <5.5 100 0.0050 <7.01 <0.0050
332400676-0015
TUCA0114AS021A 01/14/2024 983.6 <5.5 100 0.0027 <7.01 <0.0027
332400676-0016
TUCA0114ASFB001A 01/14/2024 <5.5 100 <7.01 Field Blank
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/15/2024 12:45 PM
Printed: 01/15/2024 12:45 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332400676
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/15/2024 09:55 AM
North Little Rock, AR 72118 Analysis Date:01/15/2024
Collected Date:01/14/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/15/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332400676-0017
TUCA0114AS001B 01/14/2024 985.8 <5.5 100 0.0027 <7.01 <0.0027
332400676-0018
TUCA0114AS002B 01/14/2024 1049 <5.5 100 0.0026 <7.01 <0.0026
332400676-0019
TUCA0114AS003B 01/14/2024 1052.5 <5.5 100 0.0026 <7.01 <0.0026
332400676-0020
TUCA0114AS004B 01/14/2024 1049 <5.5 100 0.0026 <7.01 <0.0026
332400676-0021
TUCA0114AS005B 01/14/2024 974.7 <5.5 100 0.0028 <7.01 <0.0028
332400676-0022
TUCA0114AS006B 01/14/2024 876.6 <5.5 100 0.0031 <7.01 <0.0031
332400676-0023
TUCA0114AS007B 01/14/2024 1036.3 <5.5 100 0.0026 <7.01 <0.0026
332400676-0024
TUCA0114AS008B 01/14/2024 1002 <5.5 100 0.0027 <7.01 <0.0027
332400676-0025
TUCA0114AS009B 01/14/2024 1014.6 <5.5 100 0.0027 <7.01 <0.0027
332400676-0026
TUCA0114AS010B 01/14/2024 931.9 <5.5 100 0.0029 <7.01 <0.0029
332400676-0027
TUCA0114ASFB001B 01/14/2024 <5.5 100 <7.01 Field Blank
332400676-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Thanh Nguyen PCM 28
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/15/2024 12:45 PM
Printed: 01/15/2024 12:45 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2