HomeMy WebLinkAboutPCM 01302024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332401632
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/31/2024 09:35 AM
North Little Rock, AR 72118 Analysis Date:01/31/2024
Collected Date:01/30/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0130AS001A 01/30/2024 1045 <5.5 100 0.0026 <7.01 <0.0026
332401632-0001
TUCA0130AS002A 01/30/2024 1081.5 <5.5 100 0.0025 <7.01 <0.0025
332401632-0002
TUCA0130AS003A 01/30/2024 1066.9 <5.5 100 0.0025 <7.01 <0.0025
332401632-0003
TUCA0130AS004A 01/30/2024 958.9 <5.5 100 0.0028 <7.01 <0.0028
332401632-0004
TUCA0130AS005A 01/30/2024 1035.3 <5.5 100 0.0026 <7.01 <0.0026
332401632-0005
TUCA0130AS006A 01/30/2024 1062.9 <5.5 100 0.0025 <7.01 <0.0025
332401632-0006
TUCA0130AS007A 01/30/2024 1038.4 <5.5 100 0.0026 <7.01 <0.0026
332401632-0007
TUCA0130AS008A 01/30/2024 1096.3 <5.5 100 0.0025 <7.01 <0.0025
332401632-0008
TUCA0130AS009A 01/30/2024 1085 <5.5 100 0.0025 <7.01 <0.0025
332401632-0009
TUCA0130AS010A 01/30/2024 1030.8 <5.5 100 0.0026 <7.01 <0.0026
332401632-0010
TUCA0130AS013A 01/30/2024 1069.1 <5.5 100 0.0025 <7.01 <0.0025
332401632-0011
TUCA0130AS014A 01/30/2024 1094.5 <5.5 100 0.0025 <7.01 <0.0025
332401632-0012
TUCA0130AS015A 01/30/2024 496.1 <5.5 100 0.0054 <7.01 <0.0054
332401632-0013
TUCA0130AS017A 01/30/2024 1064 <5.5 100 0.0025 <7.01 <0.0025
332401632-0014
TUCA0130AS019A 01/30/2024 1077 <5.5 100 0.0025 <7.01 <0.0025
332401632-0015
TUCA0130AS021A 01/30/2024 1046 <5.5 100 0.0026 <7.01 <0.0026
332401632-0016
TUCA0130ASFB001A 01/30/2024 <5.5 100 <7.01 Field Blank
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/31/2024 01:39 PM
Printed: 01/31/2024 01:39 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332401632
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:01/31/2024 09:35 AM
North Little Rock, AR 72118 Analysis Date:01/31/2024
Collected Date:01/30/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332401632-0017
TUCA0130AS001B 01/30/2024 713.5 <5.5 100 0.0038 <7.01 <0.0038
332401632-0018
TUCA0130AS002B 01/30/2024 1064.9 <5.5 100 0.0025 <7.01 <0.0025
332401632-0019
TUCA0130AS003B 01/30/2024 1062 <5.5 100 0.0025 <7.01 <0.0025
332401632-0020
TUCA0130AS004B 01/30/2024 1039 <5.5 100 0.0026 <7.01 <0.0026
332401632-0021
TUCA0130AS005B 01/30/2024 985.6 <5.5 100 0.0027 <7.01 <0.0027
332401632-0022
TUCA0130AS006B 01/30/2024 723.9 <5.5 100 0.0037 <7.01 <0.0037
332401632-0023
TUCA0130AS007B 01/30/2024 905.7 <5.5 100 0.0030 <7.01 <0.0030
332401632-0024
TUCA0130AS008B 01/30/2024 1001.4 <5.5 100 0.0027 <7.01 <0.0027
332401632-0025
TUCA0130AS009B 01/30/2024 967.9 <5.5 100 0.0028 <7.01 <0.0028
332401632-0026
TUCA0130AS010B 01/30/2024 917 <5.5 100 0.0029 <7.01 <0.0029
332401632-0027
TUCA0130ASFB001B 01/30/2024 <5.5 100 <7.01 Field Blank
332401632-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 28
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 01/31/2024 01:39 PM
Printed: 01/31/2024 01:39 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2