Loading...
HomeMy WebLinkAboutPCM 01302024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332401632 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:01/31/2024 09:35 AM North Little Rock, AR 72118 Analysis Date:01/31/2024 Collected Date:01/30/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0130AS001A 01/30/2024 1045 <5.5 100 0.0026 <7.01 <0.0026 332401632-0001 TUCA0130AS002A 01/30/2024 1081.5 <5.5 100 0.0025 <7.01 <0.0025 332401632-0002 TUCA0130AS003A 01/30/2024 1066.9 <5.5 100 0.0025 <7.01 <0.0025 332401632-0003 TUCA0130AS004A 01/30/2024 958.9 <5.5 100 0.0028 <7.01 <0.0028 332401632-0004 TUCA0130AS005A 01/30/2024 1035.3 <5.5 100 0.0026 <7.01 <0.0026 332401632-0005 TUCA0130AS006A 01/30/2024 1062.9 <5.5 100 0.0025 <7.01 <0.0025 332401632-0006 TUCA0130AS007A 01/30/2024 1038.4 <5.5 100 0.0026 <7.01 <0.0026 332401632-0007 TUCA0130AS008A 01/30/2024 1096.3 <5.5 100 0.0025 <7.01 <0.0025 332401632-0008 TUCA0130AS009A 01/30/2024 1085 <5.5 100 0.0025 <7.01 <0.0025 332401632-0009 TUCA0130AS010A 01/30/2024 1030.8 <5.5 100 0.0026 <7.01 <0.0026 332401632-0010 TUCA0130AS013A 01/30/2024 1069.1 <5.5 100 0.0025 <7.01 <0.0025 332401632-0011 TUCA0130AS014A 01/30/2024 1094.5 <5.5 100 0.0025 <7.01 <0.0025 332401632-0012 TUCA0130AS015A 01/30/2024 496.1 <5.5 100 0.0054 <7.01 <0.0054 332401632-0013 TUCA0130AS017A 01/30/2024 1064 <5.5 100 0.0025 <7.01 <0.0025 332401632-0014 TUCA0130AS019A 01/30/2024 1077 <5.5 100 0.0025 <7.01 <0.0025 332401632-0015 TUCA0130AS021A 01/30/2024 1046 <5.5 100 0.0026 <7.01 <0.0026 332401632-0016 TUCA0130ASFB001A 01/30/2024 <5.5 100 <7.01 Field Blank LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 01/31/2024 01:39 PM Printed: 01/31/2024 01:39 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332401632 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:01/31/2024 09:35 AM North Little Rock, AR 72118 Analysis Date:01/31/2024 Collected Date:01/30/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332401632-0017 TUCA0130AS001B 01/30/2024 713.5 <5.5 100 0.0038 <7.01 <0.0038 332401632-0018 TUCA0130AS002B 01/30/2024 1064.9 <5.5 100 0.0025 <7.01 <0.0025 332401632-0019 TUCA0130AS003B 01/30/2024 1062 <5.5 100 0.0025 <7.01 <0.0025 332401632-0020 TUCA0130AS004B 01/30/2024 1039 <5.5 100 0.0026 <7.01 <0.0026 332401632-0021 TUCA0130AS005B 01/30/2024 985.6 <5.5 100 0.0027 <7.01 <0.0027 332401632-0022 TUCA0130AS006B 01/30/2024 723.9 <5.5 100 0.0037 <7.01 <0.0037 332401632-0023 TUCA0130AS007B 01/30/2024 905.7 <5.5 100 0.0030 <7.01 <0.0030 332401632-0024 TUCA0130AS008B 01/30/2024 1001.4 <5.5 100 0.0027 <7.01 <0.0027 332401632-0025 TUCA0130AS009B 01/30/2024 967.9 <5.5 100 0.0028 <7.01 <0.0028 332401632-0026 TUCA0130AS010B 01/30/2024 917 <5.5 100 0.0029 <7.01 <0.0029 332401632-0027 TUCA0130ASFB001B 01/30/2024 <5.5 100 <7.01 Field Blank 332401632-0028 The results reported have been blank corrected as applicable. Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Tony Salgado PCM 28 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.28, 21-50 fibers = 0.25, 51-100 fibers = 0.2. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.35. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 01/31/2024 01:39 PM Printed: 01/31/2024 01:39 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2