HomeMy WebLinkAboutPCM 02092024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332402314
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:02/10/2024 09:40 AM
North Little Rock, AR 72118 Analysis Date:02/10/2024
Collected Date:02/09/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0209AS001A 02/09/2024 1053.9 <5.5 100 0.0026 <7.01 <0.0026
332402314-0001
TUCA0209AS002A 02/09/2024 1087.9 <5.5 100 0.0025 <7.01 <0.0025
332402314-0002
TUCA0209AS003A 02/09/2024 1045.2 <5.5 100 0.0026 <7.01 <0.0026
332402314-0003
TUCA0209AS004A 02/09/2024 921.6 <5.5 100 0.0029 <7.01 <0.0029
332402314-0004
TUCA0209AS005A 02/09/2024 1030.9 <5.5 100 0.0026 <7.01 <0.0026
332402314-0005
TUCA0209AS006A 02/09/2024 1061.3 <5.5 100 0.0025 <7.01 <0.0025
332402314-0006
TUCA0209AS007A 02/09/2024 1100.1 <5.5 100 0.0024 <7.01 <0.0024
332402314-0007
TUCA0209AS008A 02/09/2024 1096.7 <5.5 100 0.0025 <7.01 <0.0025
332402314-0008
TUCA0209AS009A 02/09/2024 1073 <5.5 100 0.0025 <7.01 <0.0025
332402314-0009
TUCA0209AS010A 02/09/2024 1010.7 <5.5 100 0.0027 <7.01 <0.0027
332402314-0010
TUCA0209AS013A 02/09/2024 1080.8 <5.5 100 0.0025 <7.01 <0.0025
332402314-0011
TUCA0209AS014A 02/09/2024 885.2 <5.5 100 0.0030 <7.01 <0.0030
332402314-0012
TUCA0209AS017A 02/09/2024 956.9 <5.5 100 0.0028 <7.01 <0.0028
332402314-0013
TUCA0209AS018A 02/09/2024 977.4 <5.5 100 0.0028 <7.01 <0.0028
332402314-0014
TUCA0209AS019A 02/09/2024 687.9 <5.5 100 0.0039 <7.01 <0.0039
332402314-0015
TUCA0209AS021A 02/09/2024 922.2 <5.5 100 0.0029 <7.01 <0.0029
332402314-0016
TUCA0209ASFB001A 02/09/2024 <5.5 100 <7.01 Field Blank
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 02/10/2024 02:20 PM
Printed: 02/10/2024 02:21 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332402314
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:02/10/2024 09:40 AM
North Little Rock, AR 72118 Analysis Date:02/10/2024
Collected Date:02/09/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332402314-0017
TUCA0209AS001B 02/09/2024 1015.8 <5.5 100 0.0027 <7.01 <0.0027
332402314-0018
TUCA0209AS002B 02/09/2024 1064.4 <5.5 100 0.0025 <7.01 <0.0025
332402314-0019
TUCA0209AS003B 02/09/2024 1075.2 <5.5 100 0.0025 <7.01 <0.0025
332402314-0020
TUCA0209AS004B 02/09/2024 1057 <5.5 100 0.0025 <7.01 <0.0025
332402314-0021
TUCA0209AS005B 02/09/2024 1052.6 <5.5 100 0.0026 <7.01 <0.0026
332402314-0022
TUCA0209AS006B 02/09/2024 1049.4 <5.5 100 0.0026 <7.01 <0.0026
332402314-0023
TUCA0209AS007B 02/09/2024 1013.1 <5.5 100 0.0027 <7.01 <0.0027
332402314-0024
TUCA0209AS008B 02/09/2024 1060.8 <5.5 100 0.0025 <7.01 <0.0025
332402314-0025
TUCA0209AS009B 02/09/2024 1084.9 <5.5 100 0.0025 <7.01 <0.0025
332402314-0026
TUCA0209AS010B 02/09/2024 1072 <5.5 100 0.0025 <7.01 <0.0025
332402314-0027
TUCA0209ASFB001B 02/09/2024 <5.5 100 <7.01 Field Blank
332402314-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Jeffrey Deboo PCM 28
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 02/10/2024 02:20 PM
Printed: 02/10/2024 02:21 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2