HomeMy WebLinkAboutPCM 02252024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403182
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:02/26/2024 10:05 AM
North Little Rock, AR 72118 Analysis Date:02/26/2024
Collected Date:02/25/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0225AS001A 02/25/2024 1081.6 <5.5 100 0.0025 <7.01 <0.0025
332403182-0001
TUCA0225AS002A 02/25/2024 1080.5 <5.5 100 0.0025 <7.01 <0.0025
332403182-0002
TUCA0225AS003A 02/25/2024 1086.65 <5.5 100 0.0025 <7.01 <0.0025
332403182-0003
TUCA0225AS004A 02/25/2024 935.349 <5.5 100 0.0029 <7.01 <0.0029
332403182-0004
TUCA0225AS005A 02/25/2024 1068.36 <5.5 100 0.0025 <7.01 <0.0025
332403182-0005
TUCA0225AS006A 02/25/2024 1078.93 <5.5 100 0.0025 <7.01 <0.0025
332403182-0006
TUCA0225AS007A 02/25/2024 1097.21 <5.5 100 0.0025 <7.01 <0.0025
332403182-0007
TUCA0225AS008A 02/25/2024 1094.69 <5.5 100 0.0025 <7.01 <0.0025
332403182-0008
TUCA0225AS009A 02/25/2024 1082.63 <5.5 100 0.0025 <7.01 <0.0025
332403182-0009
TUCA0225AS010A 02/25/2024 1045 <5.5 100 0.0026 <7.01 <0.0026
332403182-0010
TUCA0225AS013A 02/25/2024 1128.6 <5.5 100 0.0024 <7.01 <0.0024
332403182-0011
TUCA0225AS014A 02/25/2024 838.8 <5.5 100 0.0032 <7.01 <0.0032
332403182-0012
TUCA0225AS015A 02/25/2024 953.4 <5.5 100 0.0028 <7.01 <0.0028
332403182-0013
TUCA0225AS017A 02/25/2024 846.8 <5.5 100 0.0032 <7.01 <0.0032
332403182-0014
TUCA0225AS018A 02/25/2024 1097.3 <5.5 100 0.0025 <7.01 <0.0025
332403182-0015
TUCA0225AS019A 02/25/2024 598.8 <5.5 100 0.0045 <7.01 <0.0045
332403182-0016
TUCA0225AS021A 02/25/2024 719.8 <5.5 100 0.0037 <7.01 <0.0037
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 02/26/2024 02:40 PM
Printed: 02/26/2024 02:40 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403182
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:02/26/2024 10:05 AM
North Little Rock, AR 72118 Analysis Date:02/26/2024
Collected Date:02/25/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332403182-0017
TUCA0225ASFB001A 02/25/2024 <5.5 100 <7.01 Field Blank
332403182-0018
TUCA0225AS001B 02/25/2024 1033.4 <5.5 100 0.0026 <7.01 <0.0026
332403182-0019
TUCA0225AS002B 02/25/2024 1081.5 <5.5 100 0.0025 <7.01 <0.0025
332403182-0020
TUCA0225AS003B 02/25/2024 1075.4 <5.5 100 0.0025 <7.01 <0.0025
332403182-0021
TUCA0225AS004B 02/25/2024 1078.1 <5.5 100 0.0025 <7.01 <0.0025
332403182-0022
TUCA0225AS005B 02/25/2024 1070 <5.5 100 0.0025 <7.01 <0.0025
332403182-0023
TUCA0225AS006B 02/25/2024 1036.1 <5.5 100 0.0026 <7.01 <0.0026
332403182-0024
TUCA0225AS007B 02/25/2024 1048.8 <5.5 100 0.0026 <7.01 <0.0026
332403182-0025
TUCA0225AS008B 02/25/2024 1077.3 <5.5 100 0.0025 <7.01 <0.0025
332403182-0026
TUCA0225AS009B 02/25/2024 1068.6 <5.5 100 0.0025 <7.01 <0.0025
332403182-0027
TUCA0225AS010B 02/25/2024 1073.5 <5.5 100 0.0025 <7.01 <0.0025
332403182-0028
TUCA0225ASFB001B 02/25/2024 <5.5 100 <7.01 Field Blank
332403182-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 02/26/2024 02:40 PM
Printed: 02/26/2024 02:40 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403182
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:02/26/2024 10:05 AM
North Little Rock, AR 72118 Analysis Date:02/26/2024
Collected Date:02/25/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Kaylin Luciani PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 02/26/2024 02:40 PM
Printed: 02/26/2024 02:40 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3