HomeMy WebLinkAboutPCM 02272024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403359
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:02/28/2024 09:55 AM
North Little Rock, AR 72118 Analysis Date:02/28/2024
Collected Date:02/27/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0227AS001A 02/27/2024 1064.77 <5.5 100 0.0025 <7.01 <0.0025
332403359-0001
TUCA0227AS002A 02/27/2024 1093.46 <5.5 100 0.0025 <7.01 <0.0025
332403359-0002
TUCA0227AS003A 02/27/2024 1064.38 <5.5 100 0.0025 <7.01 <0.0025
332403359-0003
TUCA0227AS004A 02/27/2024 972.904 <5.5 100 0.0028 <7.01 <0.0028
332403359-0004
TUCA0227AS005A 02/27/2024 1058.22 <5.5 100 0.0025 <7.01 <0.0025
332403359-0005
TUCA0227AS006A 02/27/2024 1059.26 <5.5 100 0.0025 <7.01 <0.0025
332403359-0006
TUCA0227AS007A 02/27/2024 1063.76 <5.5 100 0.0025 <7.01 <0.0025
332403359-0007
TUCA0227AS008A 02/27/2024 1077.28 <5.5 100 0.0025 <7.01 <0.0025
332403359-0008
TUCA0227AS009A 02/27/2024 1067.33 <5.5 100 0.0025 <7.01 <0.0025
332403359-0009
TUCA0227AS010A 02/27/2024 1057.43 <5.5 100 0.0025 <7.01 <0.0025
332403359-0010
TUCA0227AS013A 02/27/2024 1083.6 <5.5 100 0.0025 <7.01 <0.0025
332403359-0011
TUCA0227AS014A 02/27/2024 1071.1 <5.5 100 0.0025 <7.01 <0.0025
332403359-0012
TUCA0227AS015A 02/27/2024 904.5 <5.5 100 0.0030 <7.01 <0.0030
332403359-0013
TUCA0227AS017A 02/27/2024 856.3 <5.5 100 0.0031 <7.01 <0.0031
332403359-0014
TUCA0227AS018A 02/27/2024 1077.4 <5.5 100 0.0025 <7.01 <0.0025
332403359-0015
TUCA0227AS019A 02/27/2024 1096.2 <5.5 100 0.0025 <7.01 <0.0025
332403359-0016
TUCA0227AS021A 02/27/2024 970.9 <5.5 100 0.0028 <7.01 <0.0028
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 02/28/2024 03:11 PM
Printed: 02/28/2024 03:11 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403359
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:02/28/2024 09:55 AM
North Little Rock, AR 72118 Analysis Date:02/28/2024
Collected Date:02/27/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332403359-0017
TUCA0227ASFB001A 02/27/2024 <5.5 100 <7.01 Field Blank
332403359-0018
TUCA0227AS001B 02/27/2024 1005.4 <5.5 100 0.0027 <7.01 <0.0027
332403359-0019
TUCA0227AS002B 02/27/2024 1082.2 <5.5 100 0.0025 <7.01 <0.0025
332403359-0020
TUCA0227AS003B 02/27/2024 1083.7 <5.5 100 0.0025 <7.01 <0.0025
332403359-0021
TUCA0227AS004B 02/27/2024 996.5 <5.5 100 0.0027 <7.01 <0.0027
332403359-0022
TUCA0227AS005B 02/27/2024 1048.6 <5.5 100 0.0026 <7.01 <0.0026
332403359-0023
TUCA0227AS006B 02/27/2024 1006.1 <5.5 100 0.0027 <7.01 <0.0027
332403359-0024
TUCA0227AS007B 02/27/2024 1040 <5.5 100 0.0026 <7.01 <0.0026
332403359-0025
TUCA0227AS008B 02/27/2024 1038.7 <5.5 100 0.0026 <7.01 <0.0026
332403359-0026
TUCA0227AS009B 02/27/2024 1064.3 <5.5 100 0.0025 <7.01 <0.0025
332403359-0027
TUCA0227AS010B 02/27/2024 1058.8 <5.5 100 0.0025 <7.01 <0.0025
332403359-0028
TUCA0227ASFB001B 02/27/2024 <5.5 100 <7.01 Field Blank
332403359-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 02/28/2024 03:11 PM
Printed: 02/28/2024 03:11 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403359
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:02/28/2024 09:55 AM
North Little Rock, AR 72118 Analysis Date:02/28/2024
Collected Date:02/27/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Thanh Nguyen PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 02/28/2024 03:11 PM
Printed: 02/28/2024 03:11 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3