HomeMy WebLinkAboutPCM 03012024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403661
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/02/2024 09:10 AM
North Little Rock, AR 72118 Analysis Date:03/02/2024
Collected Date:03/01/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0301AS001A 03/01/2024 1038.11 <5.5 100 0.0026 <7.01 <0.0026
332403661-0001
TUCA0301AS002A 03/01/2024 1057.9 <5.5 100 0.0025 <7.01 <0.0025
332403661-0002
TUCA0301AS003A 03/01/2024 1049.49 <5.5 100 0.0026 <7.01 <0.0026
332403661-0003
TUCA0301AS004A 03/01/2024 926.78 <5.5 100 0.0029 <7.01 <0.0029
332403661-0004
TUCA0301AS005A 03/01/2024 1014.37 <5.5 100 0.0027 <7.01 <0.0027
332403661-0005
TUCA0301AS006A 03/01/2024 1053.78 <5.5 100 0.0026 <7.01 <0.0026
332403661-0006
TUCA0301AS007A 03/01/2024 1052.28 <5.5 100 0.0026 <7.01 <0.0026
332403661-0007
TUCA0301AS008A 03/01/2024 1059.75 <5.5 100 0.0025 <7.01 <0.0025
332403661-0008
TUCA0301AS009A 03/01/2024 1045.04 <5.5 100 0.0026 <7.01 <0.0026
332403661-0009
TUCA0301AS010A 03/01/2024 712.422 <5.5 100 0.0038 <7.01 <0.0038
332403661-0010
TUCA0301AS013A 03/01/2024 1090.4 <5.5 100 0.0025 <7.01 <0.0025
332403661-0011
TUCA0301AS014A 03/01/2024 1069.4 <5.5 100 0.0025 <7.01 <0.0025
332403661-0012
TUCA0301AS015A 03/01/2024 896.9 <5.5 100 0.0030 <7.01 <0.0030
332403661-0013
TUCA0301AS017A 03/01/2024 844.1 <5.5 100 0.0032 <7.01 <0.0032
332403661-0014
TUCA0301AS018A 03/01/2024 781.2 <5.5 100 0.0034 <7.01 <0.0034
332403661-0015
TUCA0301AS019A 03/01/2024 1081.4 <5.5 100 0.0025 <7.01 <0.0025
332403661-0016
TUCA0301AS021A 03/01/2024 913.2 <5.5 100 0.0030 <7.01 <0.0030
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/02/2024 02:07 PM
Printed: 03/02/2024 02:07 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403661
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/02/2024 09:10 AM
North Little Rock, AR 72118 Analysis Date:03/02/2024
Collected Date:03/01/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332403661-0017
TUCA0301ASFB001A 03/01/2024 <5.5 100 <7.01 Field Blank
332403661-0018
TUCA0301AS001B 03/01/2024 1021.4 <5.5 100 0.0026 <7.01 <0.0026
332403661-0019
TUCA0301AS002B 03/01/2024 1077.5 <5.5 100 0.0025 <7.01 <0.0025
332403661-0020
TUCA0301AS003B 03/01/2024 1087.8 <5.5 100 0.0025 <7.01 <0.0025
332403661-0021
TUCA0301AS004B 03/01/2024 945.8 <5.5 100 0.0028 <7.01 <0.0028
332403661-0022
TUCA0301AS005B 03/01/2024 1054.6 <5.5 100 0.0026 <7.01 <0.0026
332403661-0023
TUCA0301AS006B 03/01/2024 1000.6 <5.5 100 0.0027 <7.01 <0.0027
332403661-0024
TUCA0301AS007B 03/01/2024 1046.9 <5.5 100 0.0026 <7.01 <0.0026
332403661-0025
TUCA0301AS008B 03/01/2024 1048.6 <5.5 100 0.0026 <7.01 <0.0026
332403661-0026
TUCA0301AS009B 03/01/2024 1083.6 <5.5 100 0.0025 <7.01 <0.0025
332403661-0027
TUCA0301AS010B 03/01/2024 898.5 <5.5 100 0.0030 <7.01 <0.0030
332403661-0028
TUCA0301ASFB001B 03/01/2024 <5.5 100 <7.01 Field Blank
332403661-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/02/2024 02:07 PM
Printed: 03/02/2024 02:07 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403661
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/02/2024 09:10 AM
North Little Rock, AR 72118 Analysis Date:03/02/2024
Collected Date:03/01/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Mindy Le PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/02/2024 02:07 PM
Printed: 03/02/2024 02:07 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3