HomeMy WebLinkAboutPCM 03052024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403903
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/06/2024 09:25 AM
North Little Rock, AR 72118 Analysis Date:03/06/2024
Collected Date:03/05/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0305AS001A 03/05/2024 1061.3 <5.5 100 0.0025 <7.01 <0.0025
332403903-0001
TUCA0305AS002A 03/05/2024 933.9 <5.5 100 0.0029 <7.01 <0.0029
332403903-0002
TUCA0305AS003A 03/05/2024 1077.1 <5.5 100 0.0025 <7.01 <0.0025
332403903-0003
TUCA0305AS004A 03/05/2024 946.9 <5.5 100 0.0028 <7.01 <0.0028
332403903-0004
TUCA0305AS005A 03/05/2024 1038.1 <5.5 100 0.0026 <7.01 <0.0026
332403903-0005
TUCA0305AS006A 03/05/2024 529 <5.5 100 0.0051 <7.01 <0.0051
332403903-0006
TUCA0305AS007A 03/05/2024 1045.6 <5.5 100 0.0026 <7.01 <0.0026
332403903-0007
TUCA0305AS008A 03/05/2024 519.9 <5.5 100 0.0052 <7.01 <0.0052
332403903-0008
TUCA0305AS009A 03/05/2024 1058.2 <5.5 100 0.0025 <7.01 <0.0025
332403903-0009
TUCA0305AS010A 03/05/2024 1022.5 <5.5 100 0.0026 <7.01 <0.0026
332403903-0010
TUCA0305AS013A 03/05/2024 1090.8 <5.5 100 0.0025 <7.01 <0.0025
332403903-0011
TUCA0305AS014A 03/05/2024 1044.3 <5.5 100 0.0026 <7.01 <0.0026
332403903-0012
TUCA0305AS015A 03/05/2024 454.6 <5.5 100 0.0059 <7.01 <0.0059
332403903-0013
TUCA0305AS017A 03/05/2024 837 <5.5 100 0.0032 <7.01 <0.0032
332403903-0014
TUCA0305AS018A 03/05/2024 670.5 <5.5 100 0.0040 <7.01 <0.0040
332403903-0015
TUCA0305AS019A 03/05/2024 1089.7 <5.5 100 0.0025 <7.01 <0.0025
332403903-0016
TUCA0305AS021A 03/05/2024 909.3 <5.5 100 0.0030 <7.01 <0.0030
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/06/2024 01:37 PM
Printed: 03/06/2024 01:37 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403903
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/06/2024 09:25 AM
North Little Rock, AR 72118 Analysis Date:03/06/2024
Collected Date:03/05/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332403903-0017
TUCA0305ASFB001A 03/05/2024 <5.5 100 <7.01 Field Blank
332403903-0018
TUCA0305AS001B 03/05/2024 1032.5 <5.5 100 0.0026 <7.01 <0.0026
332403903-0019
TUCA0305AS002B 03/05/2024 1081.8 <5.5 100 0.0025 <7.01 <0.0025
332403903-0020
TUCA0305AS003B 03/05/2024 1089.3 <5.5 100 0.0025 <7.01 <0.0025
332403903-0021
TUCA0305AS004B 03/05/2024 1073.7 <5.5 100 0.0025 <7.01 <0.0025
332403903-0022
TUCA0305AS005B 03/05/2024 1053.8 <5.5 100 0.0026 <7.01 <0.0026
332403903-0023
TUCA0305AS006B 03/05/2024 1053.8 <5.5 100 0.0026 <7.01 <0.0026
332403903-0024
TUCA0305AS007B 03/05/2024 915.9 <5.5 100 0.0029 <7.01 <0.0029
332403903-0025
TUCA0305AS008B 03/05/2024 1047.4 <5.5 100 0.0026 <7.01 <0.0026
332403903-0026
TUCA0305AS009B 03/05/2024 1087.5 <5.5 100 0.0025 <7.01 <0.0025
332403903-0027
TUCA0305AS010B 03/05/2024 1085.7 <5.5 100 0.0025 <7.01 <0.0025
332403903-0028
TUCA0305ASFB001B 03/05/2024 <5.5 100 <7.01 Field Blank
332403903-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/06/2024 01:37 PM
Printed: 03/06/2024 01:37 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332403903
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/06/2024 09:25 AM
North Little Rock, AR 72118 Analysis Date:03/06/2024
Collected Date:03/05/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Alexis Rodriguez PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/06/2024 01:37 PM