Loading...
HomeMy WebLinkAboutPCM 03082024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332404196 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/09/2024 09:25 AM North Little Rock, AR 72118 Analysis Date:03/09/2024 Collected Date:03/08/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0308AS001A 03/08/2024 1064.2 <5.5 100 0.0025 <7.01 <0.0025 332404196-0001 TUCA0308AS002A 03/08/2024 1063.9 <5.5 100 0.0025 <7.01 <0.0025 332404196-0002 TUCA0308AS003A 03/08/2024 1069.9 <5.5 100 0.0025 <7.01 <0.0025 332404196-0003 TUCA0308AS004A 03/08/2024 942 <5.5 100 0.0029 <7.01 <0.0029 332404196-0004 TUCA0308AS005A 03/08/2024 1058.1 <5.5 100 0.0025 <7.01 <0.0025 332404196-0005 TUCA0308AS006A 03/08/2024 1051.2 <5.5 100 0.0026 <7.01 <0.0026 332404196-0006 TUCA0308AS007A 03/08/2024 1053.9 <5.5 100 0.0026 <7.01 <0.0026 332404196-0007 TUCA0308AS008A 03/08/2024 1048.2 <5.5 100 0.0026 <7.01 <0.0026 332404196-0008 TUCA0308AS009A 03/08/2024 1052.4 <5.5 100 0.0026 <7.01 <0.0026 332404196-0009 TUCA0308AS010A 03/08/2024 1038.7 <5.5 100 0.0026 <7.01 <0.0026 332404196-0010 TUCA0308AS013A 03/08/2024 1091 <5.5 100 0.0025 <7.01 <0.0025 332404196-0011 TUCA0308AS014A 03/08/2024 1074.1 <5.5 100 0.0025 <7.01 <0.0025 332404196-0012 TUCA0308AS015A 03/08/2024 1009.8 <5.5 100 0.0027 <7.01 <0.0027 332404196-0013 TUCA0308AS017A 03/08/2024 995.7 <5.5 100 0.0027 <7.01 <0.0027 332404196-0014 TUCA0308AS018A 03/08/2024 631.9 <5.5 100 0.0043 <7.01 <0.0043 332404196-0015 TUCA0308AS019A 03/08/2024 902.1 <5.5 100 0.0030 <7.01 <0.0030 332404196-0016 TUCA0308AS021A 03/08/2024 899.9 <5.5 100 0.0030 <7.01 <0.0030 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/09/2024 01:09 PM Printed: 03/09/2024 01:09 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332404196 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/09/2024 09:25 AM North Little Rock, AR 72118 Analysis Date:03/09/2024 Collected Date:03/08/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332404196-0017 TUCA0308ASFB001A 03/08/2024 <5.5 100 <7.01 Field Blank 332404196-0018 TUCA0308AS001B 03/08/2024 1041.2 <5.5 100 0.0026 <7.01 <0.0026 332404196-0019 TUCA0308AS002B 03/08/2024 1037.8 <5.5 100 0.0026 <7.01 <0.0026 332404196-0020 TUCA0308AS003B 03/08/2024 1092.2 <5.5 100 0.0025 <7.01 <0.0025 332404196-0021 TUCA0308AS004B 03/08/2024 1084.2 <5.5 100 0.0025 <7.01 <0.0025 332404196-0022 TUCA0308AS005B 03/08/2024 1057.4 <5.5 100 0.0025 <7.01 <0.0025 332404196-0023 TUCA0308AS006B 03/08/2024 1004.7 <5.5 100 0.0027 <7.01 <0.0027 332404196-0024 TUCA0308AS007B 03/08/2024 920.8 <5.5 100 0.0029 <7.01 <0.0029 332404196-0025 TUCA0308AS008B 03/08/2024 1056.6 <5.5 100 0.0026 <7.01 <0.0026 332404196-0026 TUCA0308AS009B 03/08/2024 1101.9 <5.5 100 0.0024 <7.01 <0.0024 332404196-0027 TUCA0308AS010B 03/08/2024 1081.7 <5.5 100 0.0025 <7.01 <0.0025 332404196-0028 TUCA0308ASFB001B 03/08/2024 <5.5 100 <7.01 Field Blank 332404196-0029 The results reported have been blank corrected as applicable. LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/09/2024 01:09 PM Printed: 03/09/2024 01:09 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332404196 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/09/2024 09:25 AM North Little Rock, AR 72118 Analysis Date:03/09/2024 Collected Date:03/08/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Mindy Le PCM 29 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/09/2024 01:09 PM Printed: 03/09/2024 01:09 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3