HomeMy WebLinkAboutPCM 03102024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404232
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/11/2024 10:40 AM
North Little Rock, AR 72118 Analysis Date:03/11/2024
Collected Date:03/10/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0310AS001A 03/10/2024 1051.6 <5.5 100 0.0026 <7.01 <0.0026
332404232-0001
TUCA0310AS002A 03/10/2024 1058 <5.5 100 0.0025 <7.01 <0.0025
332404232-0002
TUCA0310AS003A 03/10/2024 1062.7 <5.5 100 0.0025 <7.01 <0.0025
332404232-0003
TUCA0310AS004A 03/10/2024 944.5 <5.5 100 0.0029 <7.01 <0.0029
332404232-0004
TUCA0310AS005A 03/10/2024 1041.7 <5.5 100 0.0026 <7.01 <0.0026
332404232-0005
TUCA0310AS006A 03/10/2024 608.1 <5.5 100 0.0044 <7.01 <0.0044
332404232-0006
TUCA0310AS007A 03/10/2024 1058.2 <5.5 100 0.0025 <7.01 <0.0025
332404232-0007
TUCA0310AS008A 03/10/2024 1060.5 <5.5 100 0.0025 <7.01 <0.0025
332404232-0008
TUCA0310AS009A 03/10/2024 1066.9 <5.5 100 0.0025 <7.01 <0.0025
332404232-0009
TUCA0310AS010A 03/10/2024 1026 <5.5 100 0.0026 <7.01 <0.0026
332404232-0010
TUCA0310AS013A 03/10/2024 1082.1 <5.5 100 0.0025 <7.01 <0.0025
332404232-0011
TUCA0310AS014A 03/10/2024 1067 <5.5 100 0.0025 <7.01 <0.0025
332404232-0012
TUCA0310AS015A 03/10/2024 897.6 <5.5 100 0.0030 <7.01 <0.0030
332404232-0013
TUCA0310AS017A 03/10/2024 826.3 <5.5 100 0.0033 <7.01 <0.0033
332404232-0014
TUCA0310AS018A 03/10/2024 857.8 <5.5 100 0.0031 <7.01 <0.0031
332404232-0015
TUCA0310AS019A 03/10/2024 1072.8 <5.5 100 0.0025 <7.01 <0.0025
332404232-0016
TUCA0310AS021A 03/10/2024 961.5 <5.5 100 0.0028 <7.01 <0.0028
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/11/2024 02:41 PM
Printed: 03/11/2024 02:41 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404232
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/11/2024 10:40 AM
North Little Rock, AR 72118 Analysis Date:03/11/2024
Collected Date:03/10/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332404232-0017
TUCA0310ASFB001A 03/10/2024 <5.5 100 <7.01 Field Blank
332404232-0018
TUCA0310AS001B 03/10/2024 1018.7 <5.5 100 0.0026 <7.01 <0.0026
332404232-0019
TUCA0310AS002B 03/10/2024 1011.3 <5.5 100 0.0027 <7.01 <0.0027
332404232-0020
TUCA0310AS003B 03/10/2024 1084.9 <5.5 100 0.0025 <7.01 <0.0025
332404232-0021
TUCA0310AS004B 03/10/2024 1073.2 <5.5 100 0.0025 <7.01 <0.0025
332404232-0022
TUCA0310AS005B 03/10/2024 1041.9 <5.5 100 0.0026 <7.01 <0.0026
332404232-0023
TUCA0310AS006B 03/10/2024 1013.3 <5.5 100 0.0027 <7.01 <0.0027
332404232-0024
TUCA0310AS007B 03/10/2024 907.8 <5.5 100 0.0030 <7.01 <0.0030
332404232-0025
TUCA0310AS008B 03/10/2024 1038.6 <5.5 100 0.0026 <7.01 <0.0026
332404232-0026
TUCA0310AS009B 03/10/2024 1069.4 <5.5 100 0.0025 <7.01 <0.0025
332404232-0027
TUCA0310AS010B 03/10/2024 1066.2 <5.5 100 0.0025 <7.01 <0.0025
332404232-0028
TUCA0310ASFB001B 03/10/2024 <5.5 100 <7.01 Field Blank
332404232-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/11/2024 02:41 PM
Printed: 03/11/2024 02:41 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404232
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/11/2024 10:40 AM
North Little Rock, AR 72118 Analysis Date:03/11/2024
Collected Date:03/10/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Thanh Nguyen PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/11/2024 02:41 PM
Printed: 03/11/2024 02:41 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3