HomeMy WebLinkAboutPCM 03132024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404549
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/14/2024 10:05 AM
North Little Rock, AR 72118 Analysis Date:03/14/2024
Collected Date:03/13/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0313AS001A 03/13/2024 1073.4 <5.5 100 0.0025 <7.01 <0.0025
332404549-0001
TUCA0313AS002A 03/13/2024 1070.8 <5.5 100 0.0025 <7.01 <0.0025
332404549-0002
TUCA0313AS003A 03/13/2024 1073.2 <5.5 100 0.0025 <7.01 <0.0025
332404549-0003
TUCA0313AS004A 03/13/2024 1069.2 <5.5 100 0.0025 <7.01 <0.0025
332404549-0004
TUCA0313AS005A 03/13/2024 1075.4 <5.5 100 0.0025 <7.01 <0.0025
332404549-0005
TUCA0313AS006A 03/13/2024 1065.1 <5.5 100 0.0025 <7.01 <0.0025
332404549-0006
TUCA0313AS007A 03/13/2024 1057.6 <5.5 100 0.0025 <7.01 <0.0025
332404549-0007
TUCA0313AS008A 03/13/2024 1061.6 <5.5 100 0.0025 <7.01 <0.0025
332404549-0008
TUCA0313AS009A 03/13/2024 1064.7 <5.5 100 0.0025 <7.01 <0.0025
332404549-0009
TUCA0313AS010A 03/13/2024 1062.5 <5.5 100 0.0025 <7.01 <0.0025
332404549-0010
TUCA0313AS013A 03/13/2024 1092.9 <5.5 100 0.0025 <7.01 <0.0025
332404549-0011
TUCA0313AS014A 03/13/2024 1107 <5.5 100 0.0024 <7.01 <0.0024
332404549-0012
TUCA0313AS015A 03/13/2024 1090.4 <5.5 100 0.0025 <7.01 <0.0025
332404549-0013
TUCA0313AS017A 03/13/2024 1089 <5.5 100 0.0025 <7.01 <0.0025
332404549-0014
TUCA0313AS018A 03/13/2024 749.5 <5.5 100 0.0036 <7.01 <0.0036
332404549-0015
TUCA0313AS019A 03/13/2024 1090.1 <5.5 100 0.0025 <7.01 <0.0025
332404549-0016
TUCA0313AS021A 03/13/2024 1086.1 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/14/2024 02:17 PM
Printed: 03/14/2024 02:17 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404549
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/14/2024 10:05 AM
North Little Rock, AR 72118 Analysis Date:03/14/2024
Collected Date:03/13/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332404549-0017
TUCA0313ASFB001A 03/13/2024 <5.5 100 <7.01 Field Blank
332404549-0018
TUCA0313AS001B 03/13/2024 838.4 <5.5 100 0.0032 <7.01 <0.0032
332404549-0019
TUCA0313AS002B 03/13/2024 1087.6 <5.5 100 0.0025 <7.01 <0.0025
332404549-0020
TUCA0313AS003B 03/13/2024 1083.2 <5.5 100 0.0025 <7.01 <0.0025
332404549-0021
TUCA0313AS004B 03/13/2024 1081.9 <5.5 100 0.0025 <7.01 <0.0025
332404549-0022
TUCA0313AS005B 03/13/2024 1074.4 <5.5 100 0.0025 <7.01 <0.0025
332404549-0023
TUCA0313AS006B 03/13/2024 1070.2 <5.5 100 0.0025 <7.01 <0.0025
332404549-0024
TUCA0313AS007B 03/13/2024 1069.8 <5.5 100 0.0025 <7.01 <0.0025
332404549-0025
TUCA0313AS008B 03/13/2024 1065.6 <5.5 100 0.0025 <7.01 <0.0025
332404549-0026
TUCA0313AS009B 03/13/2024 1067.6 <5.5 100 0.0025 <7.01 <0.0025
332404549-0027
TUCA0313AS010B 03/13/2024 1061.8 <5.5 100 0.0025 <7.01 <0.0025
332404549-0028
TUCA0313ASFB001B 03/13/2024 <5.5 100 <7.01 Field Blank
332404549-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/14/2024 02:17 PM
Printed: 03/14/2024 02:17 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404549
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/14/2024 10:05 AM
North Little Rock, AR 72118 Analysis Date:03/14/2024
Collected Date:03/13/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/14/2024 02:17 PM
Printed: 03/14/2024 02:17 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3