HomeMy WebLinkAboutPCM 03152024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404718
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/16/2024 09:45 AM
North Little Rock, AR 72118 Analysis Date:03/16/2024
Collected Date:03/15/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0315AS001A 03/15/2024 1056.4 <5.5 100 0.0026 <7.01 <0.0026
332404718-0001
TUCA0315AS002A 03/15/2024 1057 <5.5 100 0.0025 <7.01 <0.0025
332404718-0002
TUCA0315AS003A 03/15/2024 1051.3 <5.5 100 0.0026 <7.01 <0.0026
332404718-0003
TUCA0315AS004A 03/15/2024 1041.8 <5.5 100 0.0026 <7.01 <0.0026
332404718-0004
TUCA0315AS005A 03/15/2024 1043.2 <5.5 100 0.0026 <7.01 <0.0026
332404718-0005
TUCA0315AS006A 03/15/2024 595.1 <5.5 100 0.0045 <7.01 <0.0045
332404718-0006
TUCA0315AS007A 03/15/2024 1032.8 <5.5 100 0.0026 <7.01 <0.0026
332404718-0007
TUCA0315AS008A 03/15/2024 1033 <5.5 100 0.0026 <7.01 <0.0026
332404718-0008
TUCA0315AS009A 03/15/2024 1033.6 <5.5 100 0.0026 <7.01 <0.0026
332404718-0009
TUCA0315AS010A 03/15/2024 1031.8 <5.5 100 0.0026 <7.01 <0.0026
332404718-0010
TUCA0315AS013A 03/15/2024 1096.2 <5.5 100 0.0025 <7.01 <0.0025
332404718-0011
TUCA0315AS014A 03/15/2024 1072.9 <5.5 100 0.0025 <7.01 <0.0025
332404718-0012
TUCA0315AS015A 03/15/2024 847.7 <5.5 100 0.0032 <7.01 <0.0032
332404718-0013
TUCA0315AS017A 03/15/2024 856.8 <5.5 100 0.0031 <7.01 <0.0031
332404718-0014
TUCA0315AS018A 03/15/2024 841.5 <5.5 100 0.0032 <7.01 <0.0032
332404718-0015
TUCA0315AS019A 03/15/2024 1101.7 <5.5 100 0.0024 <7.01 <0.0024
332404718-0016
TUCA0315AS021A 03/15/2024 1213.7 <5.5 100 0.0022 <7.01 <0.0022
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/16/2024 02:53 PM
Printed: 03/16/2024 02:53 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404718
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/16/2024 09:45 AM
North Little Rock, AR 72118 Analysis Date:03/16/2024
Collected Date:03/15/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332404718-0017
TUCA0315ASFB001A 03/15/2024 <5.5 100 <7.01 Field Blank
332404718-0018
TUCA0315AS001B 03/15/2024 1022.8 <5.5 100 0.0026 <7.01 <0.0026
332404718-0019
TUCA0315AS002B 03/15/2024 1043.2 <5.5 100 0.0026 <7.01 <0.0026
332404718-0020
TUCA0315AS003B 03/15/2024 1080.5 <5.5 100 0.0025 <7.01 <0.0025
332404718-0021
TUCA0315AS004B 03/15/2024 1075.2 <5.5 100 0.0025 <7.01 <0.0025
332404718-0022
TUCA0315AS005B 03/15/2024 1076.8 <5.5 100 0.0025 <7.01 <0.0025
332404718-0023
TUCA0315AS006B 03/15/2024 1028.6 <5.5 100 0.0026 <7.01 <0.0026
332404718-0024
TUCA0315AS007B 03/15/2024 998.7 <5.5 100 0.0027 <7.01 <0.0027
332404718-0025
TUCA0315AS008B 03/15/2024 1005.8 <5.5 100 0.0027 <7.01 <0.0027
332404718-0026
TUCA0315AS009B 03/15/2024 1010.1 <5.5 100 0.0027 <7.01 <0.0027
332404718-0027
TUCA0315AS010B 03/15/2024 1007.3 <5.5 100 0.0027 <7.01 <0.0027
332404718-0028
TUCA0315ASFB001B 03/15/2024 <5.5 100 <7.01 Field Blank
332404718-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/16/2024 02:53 PM
Printed: 03/16/2024 02:53 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332404718
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/16/2024 09:45 AM
North Little Rock, AR 72118 Analysis Date:03/16/2024
Collected Date:03/15/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Mindy Le PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/16/2024 02:53 PM
Printed: 03/16/2024 02:53 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3