Loading...
HomeMy WebLinkAboutPCM 03252024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332405446 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/26/2024 11:05 AM North Little Rock, AR 72118 Analysis Date:03/26/2024 Collected Date:03/25/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0325AS001A 03/25/2024 569.2 <5.5 100 0.0047 <7.01 <0.0047 332405446-0001 TUCA0325AS002A 03/25/2024 1049.5 <5.5 100 0.0026 <7.01 <0.0026 332405446-0002 TUCA0325AS003A 03/25/2024 1031 <5.5 100 0.0026 <7.01 <0.0026 332405446-0003 TUCA0325AS004A 03/25/2024 780.2 <5.5 100 0.0035 <7.01 <0.0035 332405446-0004 TUCA0325AS005A 03/25/2024 1043.5 <5.5 100 0.0026 <7.01 <0.0026 332405446-0005 TUCA0325AS006A 03/25/2024 1058.3 <5.5 100 0.0025 <7.01 <0.0025 332405446-0006 TUCA0325AS007A 03/25/2024 1056.9 <5.5 100 0.0025 <7.01 <0.0025 332405446-0007 TUCA0325AS008A 03/25/2024 1006.6 <5.5 100 0.0027 <7.01 <0.0027 332405446-0008 TUCA0325AS009A 03/25/2024 1067.4 <5.5 100 0.0025 <7.01 <0.0025 332405446-0009 TUCA0325AS010A 03/25/2024 986.5 <5.5 100 0.0027 <7.01 <0.0027 332405446-0010 TUCA0325AS013A 03/25/2024 1079 <5.5 100 0.0025 <7.01 <0.0025 332405446-0011 TUCA0325AS014A 03/25/2024 784.6 <5.5 100 0.0034 <7.01 <0.0034 332405446-0012 TUCA0325AS015A 03/25/2024 1090 <5.5 100 0.0025 <7.01 <0.0025 332405446-0013 TUCA0325AS017A 03/25/2024 811.3 <5.5 100 0.0033 <7.01 <0.0033 332405446-0014 TUCA0325AS018A 03/25/2024 904.1 <5.5 100 0.0030 <7.01 <0.0030 332405446-0015 TUCA0325AS019A 03/25/2024 1133.5 <5.5 100 0.0024 <7.01 <0.0024 332405446-0016 TUCA0325AS021A 03/25/2024 1096 <5.5 100 0.0025 <7.01 <0.0025 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/26/2024 04:39 PM Printed: 03/26/2024 04:39 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332405446 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/26/2024 11:05 AM North Little Rock, AR 72118 Analysis Date:03/26/2024 Collected Date:03/25/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332405446-0017 TUCA0325ASFB001A 03/25/2024 <5.5 100 <7.01 Field Blank 332405446-0018 TUCA0325AS001B 03/25/2024 1068.2 <5.5 100 0.0025 <7.01 <0.0025 332405446-0019 TUCA0325AS002B 03/25/2024 1003.7 <5.5 100 0.0027 <7.01 <0.0027 332405446-0020 TUCA0325AS003B 03/25/2024 1036.8 <5.5 100 0.0026 <7.01 <0.0026 332405446-0021 TUCA0325AS004B 03/25/2024 1058 <5.5 100 0.0025 <7.01 <0.0025 332405446-0022 TUCA0325AS005B 03/25/2024 963.3 <5.5 100 0.0028 <7.01 <0.0028 332405446-0023 TUCA0325AS006B 03/25/2024 925.9 <5.5 100 0.0029 <7.01 <0.0029 332405446-0024 TUCA0325AS007B 03/25/2024 551.8 <5.5 100 0.0049 <7.01 <0.0049 332405446-0025 TUCA0325AS008B 03/25/2024 980.5 <5.5 100 0.0027 <7.01 <0.0027 332405446-0026 TUCA0325AS009B 03/25/2024 1078.2 <5.5 100 0.0025 <7.01 <0.0025 332405446-0027 TUCA0325AS010B 03/25/2024 979.6 <5.5 100 0.0028 <7.01 <0.0028 332405446-0028 TUCA0325ASFB001B 03/25/2024 <5.5 100 <7.01 Field Blank 332405446-0029 The results reported have been blank corrected as applicable. LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/26/2024 04:39 PM Printed: 03/26/2024 04:39 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332405446 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/26/2024 11:05 AM North Little Rock, AR 72118 Analysis Date:03/26/2024 Collected Date:03/25/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Tony Salgado PCM 29 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/26/2024 04:39 PM Printed: 03/26/2024 04:39 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3