HomeMy WebLinkAboutPCM 03272024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332405636 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/28/2024 10:00 AM North Little Rock, AR 72118 Analysis Date:03/28/2024 Collected Date:03/27/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0327AS001A 03/27/2024 1057.7 <5.5 100 0.0025 <7.01 <0.0025 332405636-0001 TUCA0327AS002A 03/27/2024 1064.5 <5.5 100 0.0025 <7.01 <0.0025 332405636-0002 TUCA0327AS003A 03/27/2024 1061.7 <5.5 100 0.0025 <7.01 <0.0025 332405636-0003 TUCA0327AS004A 03/27/2024 922.8 <5.5 100 0.0029 <7.01 <0.0029 332405636-0004 TUCA0327AS005A 03/27/2024 1037.2 <5.5 100 0.0026 <7.01 <0.0026 332405636-0005 TUCA0327AS006A 03/27/2024 1068.8 <5.5 100 0.0025 <7.01 <0.0025 332405636-0006 TUCA0327AS007A 03/27/2024 1068.6 <5.5 100 0.0025 <7.01 <0.0025 332405636-0007 TUCA0327AS008A 03/27/2024 1025.9 <5.5 100 0.0026 <7.01 <0.0026 332405636-0008 TUCA0327AS009A 03/27/2024 1074.8 <5.5 100 0.0025 <7.01 <0.0025 332405636-0009 TUCA0327AS010A 03/27/2024 985.5 <5.5 100 0.0027 <7.01 <0.0027 332405636-0010 TUCA0327AS013A 03/27/2024 734 <5.5 100 0.0037 <7.01 <0.0037 332405636-0011 TUCA0327AS014A 03/27/2024 731.2 <5.5 100 0.0037 <7.01 <0.0037 332405636-0012 TUCA0327AS015A 03/27/2024 1092.9 <5.5 100 0.0025 <7.01 <0.0025 332405636-0013 TUCA0327AS017A 03/27/2024 868.8 <5.5 100 0.0031 <7.01 <0.0031 332405636-0014 TUCA0327AS018A 03/27/2024 764 <5.5 100 0.0035 <7.01 <0.0035 332405636-0015 TUCA0327AS019A 03/27/2024 929.1 <5.5 100 0.0029 <7.01 <0.0029 332405636-0016 TUCA0327AS021A 03/27/2024 1094.7 <5.5 100 0.0025 <7.01 <0.0025 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/28/2024 03:08 PM Printed: 03/28/2024 03:08 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332405636 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/28/2024 10:00 AM North Little Rock, AR 72118 Analysis Date:03/28/2024 Collected Date:03/27/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332405636-0017 TUCA0327ASFB001A 03/27/2024 <5.5 100 <7.01 Field Blank 332405636-0018 TUCA0327AS001B 03/27/2024 608 <5.5 100 0.0044 <7.01 <0.0044 332405636-0019 TUCA0327AS002B 03/27/2024 1035.7 <5.5 100 0.0026 <7.01 <0.0026 332405636-0020 TUCA0327AS003B 03/27/2024 1081 <5.5 100 0.0025 <7.01 <0.0025 332405636-0021 TUCA0327AS004B 03/27/2024 1067.7 <5.5 100 0.0025 <7.01 <0.0025 332405636-0022 TUCA0327AS005B 03/27/2024 1070 <5.5 100 0.0025 <7.01 <0.0025 332405636-0023 TUCA0327AS006B 03/27/2024 1027.3 <5.5 100 0.0026 <7.01 <0.0026 332405636-0024 TUCA0327AS007B 03/27/2024 546.8 <5.5 100 0.0049 <7.01 <0.0049 332405636-0025 TUCA0327AS008B 03/27/2024 1046.9 <5.5 100 0.0026 <7.01 <0.0026 332405636-0026 TUCA0327AS009B 03/27/2024 1051.8 <5.5 100 0.0026 <7.01 <0.0026 332405636-0027 TUCA0327AS010B 03/27/2024 709.3 <5.5 100 0.0038 <7.01 <0.0038 332405636-0028 TUCA0327ASFB001B 03/27/2024 <5.5 100 <7.01 Field Blank 332405636-0029 The results reported have been blank corrected as applicable. LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/28/2024 03:08 PM Printed: 03/28/2024 03:08 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332405636 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:03/28/2024 10:00 AM North Little Rock, AR 72118 Analysis Date:03/28/2024 Collected Date:03/27/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Alexis Rodriguez PCM 29 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 03/28/2024 03:08 PM Printed: 03/28/2024 03:08 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3