HomeMy WebLinkAboutPCM 03272024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332405636
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/28/2024 10:00 AM
North Little Rock, AR 72118 Analysis Date:03/28/2024
Collected Date:03/27/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0327AS001A 03/27/2024 1057.7 <5.5 100 0.0025 <7.01 <0.0025
332405636-0001
TUCA0327AS002A 03/27/2024 1064.5 <5.5 100 0.0025 <7.01 <0.0025
332405636-0002
TUCA0327AS003A 03/27/2024 1061.7 <5.5 100 0.0025 <7.01 <0.0025
332405636-0003
TUCA0327AS004A 03/27/2024 922.8 <5.5 100 0.0029 <7.01 <0.0029
332405636-0004
TUCA0327AS005A 03/27/2024 1037.2 <5.5 100 0.0026 <7.01 <0.0026
332405636-0005
TUCA0327AS006A 03/27/2024 1068.8 <5.5 100 0.0025 <7.01 <0.0025
332405636-0006
TUCA0327AS007A 03/27/2024 1068.6 <5.5 100 0.0025 <7.01 <0.0025
332405636-0007
TUCA0327AS008A 03/27/2024 1025.9 <5.5 100 0.0026 <7.01 <0.0026
332405636-0008
TUCA0327AS009A 03/27/2024 1074.8 <5.5 100 0.0025 <7.01 <0.0025
332405636-0009
TUCA0327AS010A 03/27/2024 985.5 <5.5 100 0.0027 <7.01 <0.0027
332405636-0010
TUCA0327AS013A 03/27/2024 734 <5.5 100 0.0037 <7.01 <0.0037
332405636-0011
TUCA0327AS014A 03/27/2024 731.2 <5.5 100 0.0037 <7.01 <0.0037
332405636-0012
TUCA0327AS015A 03/27/2024 1092.9 <5.5 100 0.0025 <7.01 <0.0025
332405636-0013
TUCA0327AS017A 03/27/2024 868.8 <5.5 100 0.0031 <7.01 <0.0031
332405636-0014
TUCA0327AS018A 03/27/2024 764 <5.5 100 0.0035 <7.01 <0.0035
332405636-0015
TUCA0327AS019A 03/27/2024 929.1 <5.5 100 0.0029 <7.01 <0.0029
332405636-0016
TUCA0327AS021A 03/27/2024 1094.7 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/28/2024 03:08 PM
Printed: 03/28/2024 03:08 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332405636
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/28/2024 10:00 AM
North Little Rock, AR 72118 Analysis Date:03/28/2024
Collected Date:03/27/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332405636-0017
TUCA0327ASFB001A 03/27/2024 <5.5 100 <7.01 Field Blank
332405636-0018
TUCA0327AS001B 03/27/2024 608 <5.5 100 0.0044 <7.01 <0.0044
332405636-0019
TUCA0327AS002B 03/27/2024 1035.7 <5.5 100 0.0026 <7.01 <0.0026
332405636-0020
TUCA0327AS003B 03/27/2024 1081 <5.5 100 0.0025 <7.01 <0.0025
332405636-0021
TUCA0327AS004B 03/27/2024 1067.7 <5.5 100 0.0025 <7.01 <0.0025
332405636-0022
TUCA0327AS005B 03/27/2024 1070 <5.5 100 0.0025 <7.01 <0.0025
332405636-0023
TUCA0327AS006B 03/27/2024 1027.3 <5.5 100 0.0026 <7.01 <0.0026
332405636-0024
TUCA0327AS007B 03/27/2024 546.8 <5.5 100 0.0049 <7.01 <0.0049
332405636-0025
TUCA0327AS008B 03/27/2024 1046.9 <5.5 100 0.0026 <7.01 <0.0026
332405636-0026
TUCA0327AS009B 03/27/2024 1051.8 <5.5 100 0.0026 <7.01 <0.0026
332405636-0027
TUCA0327AS010B 03/27/2024 709.3 <5.5 100 0.0038 <7.01 <0.0038
332405636-0028
TUCA0327ASFB001B 03/27/2024 <5.5 100 <7.01 Field Blank
332405636-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/28/2024 03:08 PM
Printed: 03/28/2024 03:08 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332405636
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:03/28/2024 10:00 AM
North Little Rock, AR 72118 Analysis Date:03/28/2024
Collected Date:03/27/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Alexis Rodriguez PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 03/28/2024 03:08 PM
Printed: 03/28/2024 03:08 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3