HomeMy WebLinkAboutPCM 04022024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406054
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/03/2024 09:45 AM
North Little Rock, AR 72118 Analysis Date:04/03/2024
Collected Date:04/02/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0402AS001A 04/02/2024 1067.6 <5.5 100 0.0025 <7.01 <0.0025
332406054-0001
TUCA0402AS002A 04/02/2024 997 <5.5 100 0.0027 <7.01 <0.0027
332406054-0002
TUCA0402AS003A 04/02/2024 1084.3 <5.5 100 0.0025 <7.01 <0.0025
332406054-0003
TUCA0402AS004A 04/02/2024 913.8 <5.5 100 0.0029 <7.01 <0.0029
332406054-0004
TUCA0402AS005A 04/02/2024 1049.9 <5.5 100 0.0026 <7.01 <0.0026
332406054-0005
TUCA0402AS006A 04/02/2024 1079.6 <5.5 100 0.0025 <7.01 <0.0025
332406054-0006
TUCA0402AS007A 04/02/2024 1081 <5.5 100 0.0025 <7.01 <0.0025
332406054-0007
TUCA0402AS008A 04/02/2024 1084.6 <5.5 100 0.0025 <7.01 <0.0025
332406054-0008
TUCA0402AS009A 04/02/2024 1085 <5.5 100 0.0025 <7.01 <0.0025
332406054-0009
TUCA0402AS010A 04/02/2024 1012.5 <5.5 100 0.0027 <7.01 <0.0027
332406054-0010
TUCA0402AS013A 04/02/2024 1119.9 <5.5 100 0.0024 <7.01 <0.0024
332406054-0011
TUCA0402AS014A 04/02/2024 789.8 <5.5 100 0.0034 <7.01 <0.0034
332406054-0012
TUCA0402AS015A 04/02/2024 852 <5.5 100 0.0032 <7.01 <0.0032
332406054-0013
TUCA0402AS017A 04/02/2024 850 <5.5 100 0.0032 <7.01 <0.0032
332406054-0014
TUCA0402AS018A 04/02/2024 852.1 <5.5 100 0.0032 <7.01 <0.0032
332406054-0015
TUCA0402AS019A 04/02/2024 922.3 <5.5 100 0.0029 <7.01 <0.0029
332406054-0016
TUCA0402AS021A 04/02/2024 1090.8 <5.5 100 0.0025 <7.01 <0.0025
332406054-0017
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/03/2024 04:11 PM
Printed: 04/03/2024 04:11 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406054
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/03/2024 09:45 AM
North Little Rock, AR 72118 Analysis Date:04/03/2024
Collected Date:04/02/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0402ASFB001A 04/02/2024 <5.5 100 <7.01 Field Blank
332406054-0018
TUCA0402AS001B 04/02/2024 1014.8 <5.5 100 0.0027 <7.01 <0.0027
332406054-0019
TUCA0402AS002B 04/02/2024 1067 <5.5 100 0.0025 <7.01 <0.0025
332406054-0020
TUCA0402AS003B 04/02/2024 1063.9 <5.5 100 0.0025 <7.01 <0.0025
332406054-0021
TUCA0402AS004B 04/02/2024 1070.1 5.5 100 0.0025 7.01 0.0025
332406054-0022
TUCA0402AS005B 04/02/2024 1061.9 7.5 100 0.0025 9.55 0.0035
332406054-0023
TUCA0402AS006B 04/02/2024 991.8 <5.5 100 0.0027 <7.01 <0.0027
332406054-0024
TUCA0402AS007B 04/02/2024 1053.8 <5.5 100 0.0026 <7.01 <0.0026
332406054-0025
TUCA0402AS008B 04/02/2024 1039.7 <5.5 100 0.0026 <7.01 <0.0026
332406054-0026
TUCA0402AS009B 04/02/2024 1052.6 <5.5 100 0.0026 <7.01 <0.0026
332406054-0027
TUCA0402AS010B 04/02/2024 784.8 <5.5 100 0.0034 <7.01 <0.0034
332406054-0028
TUCA0402ASFB001B 04/02/2024 <5.5 100 <7.01 Field Blank
332406054-0029
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Christopher Miranda PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/03/2024 04:11 PM
Printed: 04/03/2024 04:11 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2