HomeMy WebLinkAboutPCM 04042024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406265
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/05/2024 10:35 AM
North Little Rock, AR 72118 Analysis Date:04/05/2024
Collected Date:04/04/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0404AS001A 04/04/2024 1095.8 <5.5 100 0.0025 <7.01 <0.0025
332406265-0001
TUCA0404AS002A 04/04/2024 1096.2 <5.5 100 0.0025 <7.01 <0.0025
332406265-0002
TUCA0404AS003A 04/04/2024 1097.6 <5.5 100 0.0025 <7.01 <0.0025
332406265-0003
TUCA0404AS004A 04/04/2024 897.9 <5.5 100 0.0030 <7.01 <0.0030
332406265-0004
TUCA0404AS005A 04/04/2024 986.1 <5.5 100 0.0027 <7.01 <0.0027
332406265-0005
TUCA0404AS006A 04/04/2024 1086.9 <5.5 100 0.0025 <7.01 <0.0025
332406265-0006
TUCA0404AS007A 04/04/2024 1087.9 <5.5 100 0.0025 <7.01 <0.0025
332406265-0007
TUCA0404AS008A 04/04/2024 1098 <5.5 100 0.0025 <7.01 <0.0025
332406265-0008
TUCA0404AS010A 04/04/2024 1018.2 <5.5 100 0.0026 <7.01 <0.0026
332406265-0009
TUCA0404AS013A 04/04/2024 1100.8 <5.5 100 0.0024 <7.01 <0.0024
332406265-0010
TUCA0404AS014A 04/04/2024 733.9 <5.5 100 0.0037 <7.01 <0.0037
332406265-0011
TUCA0404AS015A 04/04/2024 730.5 <5.5 100 0.0037 <7.01 <0.0037
332406265-0012
TUCA0404AS017A 04/04/2024 777.1 <5.5 100 0.0035 <7.01 <0.0035
332406265-0013
TUCA0404AS018A 04/04/2024 937.5 <5.5 100 0.0029 <7.01 <0.0029
332406265-0014
TUCA0404AS019A 04/04/2024 1107.3 <5.5 100 0.0024 <7.01 <0.0024
332406265-0015
TUCA0404AS021A 04/04/2024 1087.2 <5.5 100 0.0025 <7.01 <0.0025
332406265-0016
TUCA0404ASFB001A 04/04/2024 <5.5 100 <7.01 Field Blank
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/05/2024 04:26 PM
Printed: 04/05/2024 04:26 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406265
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/05/2024 10:35 AM
North Little Rock, AR 72118 Analysis Date:04/05/2024
Collected Date:04/04/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332406265-0017
TUCA0404AS001B 04/04/2024 1000.6 <5.5 100 0.0027 <7.01 <0.0027
332406265-0018
TUCA0404AS002B 04/04/2024 1006.1 <5.5 100 0.0027 <7.01 <0.0027
332406265-0019
TUCA0404AS003B 04/04/2024 1083.3 <5.5 100 0.0025 <7.01 <0.0025
332406265-0020
TUCA0404AS004B 04/04/2024 1056.5 <5.5 100 0.0026 <7.01 <0.0026
332406265-0021
TUCA0404AS005B 04/04/2024 1033.8 <5.5 100 0.0026 <7.01 <0.0026
332406265-0022
TUCA0404AS006B 04/04/2024 1011.5 <5.5 100 0.0027 <7.01 <0.0027
332406265-0023
TUCA0404AS007B 04/04/2024 1033.6 <5.5 100 0.0026 <7.01 <0.0026
332406265-0024
TUCA0404AS008B 04/04/2024 1039.7 <5.5 100 0.0026 <7.01 <0.0026
332406265-0025
TUCA0404AS009B 04/04/2024 1088.2 <5.5 100 0.0025 <7.01 <0.0025
332406265-0026
TUCA0404AS010B 04/04/2024 1027.9 <5.5 100 0.0026 <7.01 <0.0026
332406265-0027
TUCA0404ASFB001B 04/04/2024 <5.5 100 <7.01 Field Blank
332406265-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Thanh Nguyen PCM 28
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/05/2024 04:26 PM
Printed: 04/05/2024 04:26 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2