Loading...
HomeMy WebLinkAboutPCM 04042024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332406265 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:04/05/2024 10:35 AM North Little Rock, AR 72118 Analysis Date:04/05/2024 Collected Date:04/04/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0404AS001A 04/04/2024 1095.8 <5.5 100 0.0025 <7.01 <0.0025 332406265-0001 TUCA0404AS002A 04/04/2024 1096.2 <5.5 100 0.0025 <7.01 <0.0025 332406265-0002 TUCA0404AS003A 04/04/2024 1097.6 <5.5 100 0.0025 <7.01 <0.0025 332406265-0003 TUCA0404AS004A 04/04/2024 897.9 <5.5 100 0.0030 <7.01 <0.0030 332406265-0004 TUCA0404AS005A 04/04/2024 986.1 <5.5 100 0.0027 <7.01 <0.0027 332406265-0005 TUCA0404AS006A 04/04/2024 1086.9 <5.5 100 0.0025 <7.01 <0.0025 332406265-0006 TUCA0404AS007A 04/04/2024 1087.9 <5.5 100 0.0025 <7.01 <0.0025 332406265-0007 TUCA0404AS008A 04/04/2024 1098 <5.5 100 0.0025 <7.01 <0.0025 332406265-0008 TUCA0404AS010A 04/04/2024 1018.2 <5.5 100 0.0026 <7.01 <0.0026 332406265-0009 TUCA0404AS013A 04/04/2024 1100.8 <5.5 100 0.0024 <7.01 <0.0024 332406265-0010 TUCA0404AS014A 04/04/2024 733.9 <5.5 100 0.0037 <7.01 <0.0037 332406265-0011 TUCA0404AS015A 04/04/2024 730.5 <5.5 100 0.0037 <7.01 <0.0037 332406265-0012 TUCA0404AS017A 04/04/2024 777.1 <5.5 100 0.0035 <7.01 <0.0035 332406265-0013 TUCA0404AS018A 04/04/2024 937.5 <5.5 100 0.0029 <7.01 <0.0029 332406265-0014 TUCA0404AS019A 04/04/2024 1107.3 <5.5 100 0.0024 <7.01 <0.0024 332406265-0015 TUCA0404AS021A 04/04/2024 1087.2 <5.5 100 0.0025 <7.01 <0.0025 332406265-0016 TUCA0404ASFB001A 04/04/2024 <5.5 100 <7.01 Field Blank LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 04/05/2024 04:26 PM Printed: 04/05/2024 04:26 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332406265 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:04/05/2024 10:35 AM North Little Rock, AR 72118 Analysis Date:04/05/2024 Collected Date:04/04/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332406265-0017 TUCA0404AS001B 04/04/2024 1000.6 <5.5 100 0.0027 <7.01 <0.0027 332406265-0018 TUCA0404AS002B 04/04/2024 1006.1 <5.5 100 0.0027 <7.01 <0.0027 332406265-0019 TUCA0404AS003B 04/04/2024 1083.3 <5.5 100 0.0025 <7.01 <0.0025 332406265-0020 TUCA0404AS004B 04/04/2024 1056.5 <5.5 100 0.0026 <7.01 <0.0026 332406265-0021 TUCA0404AS005B 04/04/2024 1033.8 <5.5 100 0.0026 <7.01 <0.0026 332406265-0022 TUCA0404AS006B 04/04/2024 1011.5 <5.5 100 0.0027 <7.01 <0.0027 332406265-0023 TUCA0404AS007B 04/04/2024 1033.6 <5.5 100 0.0026 <7.01 <0.0026 332406265-0024 TUCA0404AS008B 04/04/2024 1039.7 <5.5 100 0.0026 <7.01 <0.0026 332406265-0025 TUCA0404AS009B 04/04/2024 1088.2 <5.5 100 0.0025 <7.01 <0.0025 332406265-0026 TUCA0404AS010B 04/04/2024 1027.9 <5.5 100 0.0026 <7.01 <0.0026 332406265-0027 TUCA0404ASFB001B 04/04/2024 <5.5 100 <7.01 Field Blank 332406265-0028 The results reported have been blank corrected as applicable. Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Thanh Nguyen PCM 28 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 04/05/2024 04:26 PM Printed: 04/05/2024 04:26 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2