HomeMy WebLinkAboutPCM 04052024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406342
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/06/2024 10:05 AM
North Little Rock, AR 72118 Analysis Date:04/06/2024
Collected Date:04/05/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0405AS002A 04/05/2024 991 <5.5 100 0.0027 <7.01 <0.0027
332406342-0001
TUCA0405AS003A 04/05/2024 1088.2 <5.5 100 0.0025 <7.01 <0.0025
332406342-0002
TUCA0405AS004A 04/05/2024 879.6 <5.5 100 0.0031 <7.01 <0.0031
332406342-0003
TUCA0405AS005A 04/05/2024 1002.4 <5.5 100 0.0027 <7.01 <0.0027
332406342-0004
TUCA0405AS006A 04/05/2024 1086.4 <5.5 100 0.0025 <7.01 <0.0025
332406342-0005
TUCA0405AS007A 04/05/2024 1086.8 <5.5 100 0.0025 <7.01 <0.0025
332406342-0006
TUCA0405AS008A 04/05/2024 1084.6 <5.5 100 0.0025 <7.01 <0.0025
332406342-0007
TUCA0405AS009A 04/05/2024 1052 <5.5 100 0.0026 <7.01 <0.0026
332406342-0008
TUCA0405AS010A 04/05/2024 1008.4 <5.5 100 0.0027 <7.01 <0.0027
332406342-0009
TUCA0405AS013A 04/05/2024 1098.7 <5.5 100 0.0025 <7.01 <0.0025
332406342-0010
TUCA0405AS014A 04/05/2024 754.4 <5.5 100 0.0036 <7.01 <0.0036
332406342-0011
TUCA0405AS015A 04/05/2024 787.1 <5.5 100 0.0034 <7.01 <0.0034
332406342-0012
TUCA0405AS017A 04/05/2024 816.9 <5.5 100 0.0033 <7.01 <0.0033
332406342-0013
TUCA0405AS018A 04/05/2024 953.3 <5.5 100 0.0028 <7.01 <0.0028
332406342-0014
TUCA0405AS019A 04/05/2024 1092.6 <5.5 100 0.0025 <7.01 <0.0025
332406342-0015
TUCA0405AS021A 04/05/2024 1097.3 <5.5 100 0.0025 <7.01 <0.0025
332406342-0016
TUCA0405ASFB001A 04/05/2024 <5.5 100 <7.01 Field Blank
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/06/2024 01:02 PM
Printed: 04/06/2024 01:02 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406342
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/06/2024 10:05 AM
North Little Rock, AR 72118 Analysis Date:04/06/2024
Collected Date:04/05/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332406342-0017
TUCA0405AS001B 04/05/2024 1002.2 <5.5 100 0.0027 <7.01 <0.0027
332406342-0018
TUCA0405AS002B 04/05/2024 1036.6 <5.5 100 0.0026 <7.01 <0.0026
332406342-0019
TUCA0405AS003B 04/05/2024 1073.9 <5.5 100 0.0025 <7.01 <0.0025
332406342-0020
TUCA0405AS004B 04/05/2024 1047 <5.5 100 0.0026 <7.01 <0.0026
332406342-0021
TUCA0405AS005B 04/05/2024 1032 <5.5 100 0.0026 <7.01 <0.0026
332406342-0022
TUCA0405AS006B 04/05/2024 998.7 <5.5 100 0.0027 <7.01 <0.0027
332406342-0023
TUCA0405AS007B 04/05/2024 1036.1 <5.5 100 0.0026 <7.01 <0.0026
332406342-0024
TUCA0405AS008B 04/05/2024 1041.2 <5.5 100 0.0026 <7.01 <0.0026
332406342-0025
TUCA0405AS009B 04/05/2024 1051.9 <5.5 100 0.0026 <7.01 <0.0026
332406342-0026
TUCA0405AS010B 04/05/2024 1016.6 <5.5 100 0.0027 <7.01 <0.0027
332406342-0027
TUCA0405ASFB001B 04/05/2024 <5.5 100 <7.01 Field Blank
332406342-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Mindy Le PCM 28
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/06/2024 01:02 PM
Printed: 04/06/2024 01:02 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2