Loading...
HomeMy WebLinkAboutPCM 04052024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332406342 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:04/06/2024 10:05 AM North Little Rock, AR 72118 Analysis Date:04/06/2024 Collected Date:04/05/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0405AS002A 04/05/2024 991 <5.5 100 0.0027 <7.01 <0.0027 332406342-0001 TUCA0405AS003A 04/05/2024 1088.2 <5.5 100 0.0025 <7.01 <0.0025 332406342-0002 TUCA0405AS004A 04/05/2024 879.6 <5.5 100 0.0031 <7.01 <0.0031 332406342-0003 TUCA0405AS005A 04/05/2024 1002.4 <5.5 100 0.0027 <7.01 <0.0027 332406342-0004 TUCA0405AS006A 04/05/2024 1086.4 <5.5 100 0.0025 <7.01 <0.0025 332406342-0005 TUCA0405AS007A 04/05/2024 1086.8 <5.5 100 0.0025 <7.01 <0.0025 332406342-0006 TUCA0405AS008A 04/05/2024 1084.6 <5.5 100 0.0025 <7.01 <0.0025 332406342-0007 TUCA0405AS009A 04/05/2024 1052 <5.5 100 0.0026 <7.01 <0.0026 332406342-0008 TUCA0405AS010A 04/05/2024 1008.4 <5.5 100 0.0027 <7.01 <0.0027 332406342-0009 TUCA0405AS013A 04/05/2024 1098.7 <5.5 100 0.0025 <7.01 <0.0025 332406342-0010 TUCA0405AS014A 04/05/2024 754.4 <5.5 100 0.0036 <7.01 <0.0036 332406342-0011 TUCA0405AS015A 04/05/2024 787.1 <5.5 100 0.0034 <7.01 <0.0034 332406342-0012 TUCA0405AS017A 04/05/2024 816.9 <5.5 100 0.0033 <7.01 <0.0033 332406342-0013 TUCA0405AS018A 04/05/2024 953.3 <5.5 100 0.0028 <7.01 <0.0028 332406342-0014 TUCA0405AS019A 04/05/2024 1092.6 <5.5 100 0.0025 <7.01 <0.0025 332406342-0015 TUCA0405AS021A 04/05/2024 1097.3 <5.5 100 0.0025 <7.01 <0.0025 332406342-0016 TUCA0405ASFB001A 04/05/2024 <5.5 100 <7.01 Field Blank LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 04/06/2024 01:02 PM Printed: 04/06/2024 01:02 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332406342 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:04/06/2024 10:05 AM North Little Rock, AR 72118 Analysis Date:04/06/2024 Collected Date:04/05/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332406342-0017 TUCA0405AS001B 04/05/2024 1002.2 <5.5 100 0.0027 <7.01 <0.0027 332406342-0018 TUCA0405AS002B 04/05/2024 1036.6 <5.5 100 0.0026 <7.01 <0.0026 332406342-0019 TUCA0405AS003B 04/05/2024 1073.9 <5.5 100 0.0025 <7.01 <0.0025 332406342-0020 TUCA0405AS004B 04/05/2024 1047 <5.5 100 0.0026 <7.01 <0.0026 332406342-0021 TUCA0405AS005B 04/05/2024 1032 <5.5 100 0.0026 <7.01 <0.0026 332406342-0022 TUCA0405AS006B 04/05/2024 998.7 <5.5 100 0.0027 <7.01 <0.0027 332406342-0023 TUCA0405AS007B 04/05/2024 1036.1 <5.5 100 0.0026 <7.01 <0.0026 332406342-0024 TUCA0405AS008B 04/05/2024 1041.2 <5.5 100 0.0026 <7.01 <0.0026 332406342-0025 TUCA0405AS009B 04/05/2024 1051.9 <5.5 100 0.0026 <7.01 <0.0026 332406342-0026 TUCA0405AS010B 04/05/2024 1016.6 <5.5 100 0.0027 <7.01 <0.0027 332406342-0027 TUCA0405ASFB001B 04/05/2024 <5.5 100 <7.01 Field Blank 332406342-0028 The results reported have been blank corrected as applicable. Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Mindy Le PCM 28 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 04/06/2024 01:02 PM Printed: 04/06/2024 01:02 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2