Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0411AS001A 04/11/2024 1068 <5.5 100 0.0025 <7.01 <0.0025
332406792-0001
TUCA0411AS002A 04/11/2024 1080.7 <5.5 100 0.0025 <7.01 <0.0025
332406792-0002
TUCA0411AS003A 04/11/2024 1076.8 <5.5 100 0.0025 <7.01 <0.0025
332406792-0003
TUCA0411AS004A 04/11/2024 906.7 <5.5 100 0.0030 <7.01 <0.0030
332406792-0004
TUCA0411AS005A 04/11/2024 1062 <5.5 100 0.0025 <7.01 <0.0025
332406792-0005
TUCA0411AS006A 04/11/2024 1068.1 <5.5 100 0.0025 <7.01 <0.0025
332406792-0006
TUCA0411AS007A 04/11/2024 1067.8 <5.5 100 0.0025 <7.01 <0.0025
332406792-0007
TUCA0411AS008A 04/11/2024 1062.8 <5.5 100 0.0025 <7.01 <0.0025
332406792-0008
TUCA0411AS009A 04/11/2024 1062.6 <5.5 100 0.0025 <7.01 <0.0025
332406792-0009
TUCA0411AS010A 04/11/2024 1050.7 <5.5 100 0.0026 <7.01 <0.0026
332406792-0010
TUCA0411AS013A 04/11/2024 1086.9 <5.5 100 0.0025 <7.01 <0.0025
332406792-0011
TUCA0411AS014A 04/11/2024 767.8 <5.5 100 0.0035 <7.01 <0.0035
332406792-0012
TUCA0411AS015A 04/11/2024 677.8 <5.5 100 0.0040 <7.01 <0.0040
332406792-0013
TUCA0411AS017A 04/11/2024 845.3 <5.5 100 0.0032 <7.01 <0.0032
332406792-0014
TUCA0411AS018A 04/11/2024 1087.5 <5.5 100 0.0025 <7.01 <0.0025
332406792-0015
TUCA0411AS019A 04/11/2024 1036 <5.5 100 0.0026 <7.01 <0.0026
332406792-0016
TUCA0411AS021A 04/11/2024 1090.3 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/12/2024 04:27 PM
Printed: 04/12/2024 04:27 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406792
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/12/2024 10:50 AM
North Little Rock, AR 72118 Analysis Date:04/12/2024
Collected Date:04/11/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332406792-0017
TUCA0411ASFB001A 04/11/2024 <5.5 100 <7.01 Field Blank
332406792-0018
TUCA0411AS001B 04/11/2024 1061 <5.5 100 0.0025 <7.01 <0.0025
332406792-0019
TUCA0411AS002B 04/11/2024 1065.2 <5.5 100 0.0025 <7.01 <0.0025
332406792-0020
TUCA0411AS003B 04/11/2024 1061.8 <5.5 100 0.0025 <7.01 <0.0025
332406792-0021
TUCA0411AS004B 04/11/2024 1063 <5.5 100 0.0025 <7.01 <0.0025
332406792-0022
TUCA0411AS005B 04/11/2024 1058.5 <5.5 100 0.0025 <7.01 <0.0025
332406792-0023
TUCA0411AS006B 04/11/2024 664.6 <5.5 100 0.0041 <7.01 <0.0041
332406792-0024
TUCA0411AS007B 04/11/2024 1057.2 <5.5 100 0.0025 <7.01 <0.0025
332406792-0025
TUCA0411AS008B 04/11/2024 752.1 <5.5 100 0.0036 <7.01 <0.0036
332406792-0026
TUCA0411AS009B 04/11/2024 1055.1 <5.5 100 0.0026 <7.01 <0.0026
332406792-0027
TUCA0411AS010B 04/11/2024 1052.1 <5.5 100 0.0026 <7.01 <0.0026
332406792-0028
TUCA0411ASFB001B 04/11/2024 <5.5 100 <7.01 Field Blank
332406792-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/12/2024 04:27 PM
Printed: 04/12/2024 04:27 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406792
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/12/2024 10:50 AM
North Little Rock, AR 72118 Analysis Date:04/12/2024
Collected Date:04/11/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/12/2024 04:27 PM
Printed: 04/12/2024 04:27 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3