Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0413AS001A 04/13/2024 1072.3 <5.5 100 0.0025 <7.01 <0.0025
332406913-0001
TUCA0413AS002A 04/13/2024 1100.3 <5.5 100 0.0024 <7.01 <0.0024
332406913-0002
TUCA0413AS003A 04/13/2024 1097.9 <5.5 100 0.0025 <7.01 <0.0025
332406913-0003
TUCA0413AS004A 04/13/2024 920.2 <5.5 100 0.0029 <7.01 <0.0029
332406913-0004
TUCA0413AS005A 04/13/2024 1025.5 <5.5 100 0.0026 <7.01 <0.0026
332406913-0005
TUCA0413AS006A 04/13/2024 1075.4 <5.5 100 0.0025 <7.01 <0.0025
332406913-0006
TUCA0413AS007A 04/13/2024 1070 <5.5 100 0.0025 <7.01 <0.0025
332406913-0007
TUCA0413AS008A 04/13/2024 1069 <5.5 100 0.0025 <7.01 <0.0025
332406913-0008
TUCA0413AS009A 04/13/2024 1062 <5.5 100 0.0025 <7.01 <0.0025
332406913-0009
TUCA0413AS010A 04/13/2024 1062.5 <5.5 100 0.0025 <7.01 <0.0025
332406913-0010
TUCA0413AS013A 04/13/2024 1087.3 <5.5 100 0.0025 <7.01 <0.0025
332406913-0011
TUCA0413AS014A 04/13/2024 734 <5.5 100 0.0037 <7.01 <0.0037
332406913-0012
TUCA0413AS015A 04/13/2024 1028.3 <5.5 100 0.0026 <7.01 <0.0026
332406913-0013
TUCA0413AS017A 04/13/2024 774 <5.5 100 0.0035 <7.01 <0.0035
332406913-0014
TUCA0413AS018A 04/13/2024 1062.7 <5.5 100 0.0025 <7.01 <0.0025
332406913-0015
TUCA0413AS019A 04/13/2024 1061.6 <5.5 100 0.0025 <7.01 <0.0025
332406913-0016
TUCA0413AS021A 04/13/2024 1084.8 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/15/2024 03:37 PM
Printed: 04/15/2024 03:37 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406913
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/15/2024 10:30 AM
North Little Rock, AR 72118 Analysis Date:04/15/2024
Collected Date:04/13/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332406913-0017
TUCA0413ASFB001A 04/13/2024 <5.5 100 <7.01 Field Blank
332406913-0018
TUCA0413AS001B 04/13/2024 1080.2 <5.5 100 0.0025 <7.01 <0.0025
332406913-0019
TUCA0413AS002B 04/13/2024 1081.8 30 100 0.0025 38.2 0.0136
332406913-0020
TUCA0413AS003B 04/13/2024 1089.3 5.5 100 0.0025 7.01 0.0025
332406913-0021
TUCA0413AS004B 04/13/2024 1075.6 26.5 100 0.0025 33.8 0.0121
332406913-0022
TUCA0413AS005B 04/13/2024 1071.4 38.5 100 0.0025 49.0 0.0176
332406913-0023
TUCA0413AS006B 04/13/2024 632.8 <5.5 100 0.0043 <7.01 <0.0043
332406913-0024
TUCA0413AS007B 04/13/2024 1035.5 25.5 100 0.0026 32.5 0.0121
332406913-0025
TUCA0413AS008B 04/13/2024 460.7 <5.5 100 0.0058 <7.01 <0.0058
332406913-0026
TUCA0413AS009B 04/13/2024 1061.1 46 100 0.0025 58.6 0.0213
332406913-0027
TUCA0413AS010B 04/13/2024 1055.9 20.5 100 0.0026 26.1 0.0095
332406913-0028
TUCA0413ASFB001B 04/13/2024 <5.5 100 <7.01 Field Blank
332406913-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/15/2024 03:37 PM
Printed: 04/15/2024 03:37 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332406913
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/15/2024 10:30 AM
North Little Rock, AR 72118 Analysis Date:04/15/2024
Collected Date:04/13/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Thanh Nguyen PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/15/2024 03:37 PM
Printed: 04/15/2024 03:37 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3