Loading...
HomeMy WebLinkAboutPCM 04132024LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332406913 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:04/15/2024 10:30 AM North Little Rock, AR 72118 Analysis Date:04/15/2024 Collected Date:04/13/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes TUCA0413AS001A 04/13/2024 1072.3 <5.5 100 0.0025 <7.01 <0.0025 332406913-0001 TUCA0413AS002A 04/13/2024 1100.3 <5.5 100 0.0024 <7.01 <0.0024 332406913-0002 TUCA0413AS003A 04/13/2024 1097.9 <5.5 100 0.0025 <7.01 <0.0025 332406913-0003 TUCA0413AS004A 04/13/2024 920.2 <5.5 100 0.0029 <7.01 <0.0029 332406913-0004 TUCA0413AS005A 04/13/2024 1025.5 <5.5 100 0.0026 <7.01 <0.0026 332406913-0005 TUCA0413AS006A 04/13/2024 1075.4 <5.5 100 0.0025 <7.01 <0.0025 332406913-0006 TUCA0413AS007A 04/13/2024 1070 <5.5 100 0.0025 <7.01 <0.0025 332406913-0007 TUCA0413AS008A 04/13/2024 1069 <5.5 100 0.0025 <7.01 <0.0025 332406913-0008 TUCA0413AS009A 04/13/2024 1062 <5.5 100 0.0025 <7.01 <0.0025 332406913-0009 TUCA0413AS010A 04/13/2024 1062.5 <5.5 100 0.0025 <7.01 <0.0025 332406913-0010 TUCA0413AS013A 04/13/2024 1087.3 <5.5 100 0.0025 <7.01 <0.0025 332406913-0011 TUCA0413AS014A 04/13/2024 734 <5.5 100 0.0037 <7.01 <0.0037 332406913-0012 TUCA0413AS015A 04/13/2024 1028.3 <5.5 100 0.0026 <7.01 <0.0026 332406913-0013 TUCA0413AS017A 04/13/2024 774 <5.5 100 0.0035 <7.01 <0.0035 332406913-0014 TUCA0413AS018A 04/13/2024 1062.7 <5.5 100 0.0025 <7.01 <0.0025 332406913-0015 TUCA0413AS019A 04/13/2024 1061.6 <5.5 100 0.0025 <7.01 <0.0025 332406913-0016 TUCA0413AS021A 04/13/2024 1084.8 <5.5 100 0.0025 <7.01 <0.0025 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 04/15/2024 03:37 PM Printed: 04/15/2024 03:37 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332406913 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:04/15/2024 10:30 AM North Little Rock, AR 72118 Analysis Date:04/15/2024 Collected Date:04/13/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes 332406913-0017 TUCA0413ASFB001A 04/13/2024 <5.5 100 <7.01 Field Blank 332406913-0018 TUCA0413AS001B 04/13/2024 1080.2 <5.5 100 0.0025 <7.01 <0.0025 332406913-0019 TUCA0413AS002B 04/13/2024 1081.8 30 100 0.0025 38.2 0.0136 332406913-0020 TUCA0413AS003B 04/13/2024 1089.3 5.5 100 0.0025 7.01 0.0025 332406913-0021 TUCA0413AS004B 04/13/2024 1075.6 26.5 100 0.0025 33.8 0.0121 332406913-0022 TUCA0413AS005B 04/13/2024 1071.4 38.5 100 0.0025 49.0 0.0176 332406913-0023 TUCA0413AS006B 04/13/2024 632.8 <5.5 100 0.0043 <7.01 <0.0043 332406913-0024 TUCA0413AS007B 04/13/2024 1035.5 25.5 100 0.0026 32.5 0.0121 332406913-0025 TUCA0413AS008B 04/13/2024 460.7 <5.5 100 0.0058 <7.01 <0.0058 332406913-0026 TUCA0413AS009B 04/13/2024 1061.1 46 100 0.0025 58.6 0.0213 332406913-0027 TUCA0413AS010B 04/13/2024 1055.9 20.5 100 0.0026 26.1 0.0095 332406913-0028 TUCA0413ASFB001B 04/13/2024 <5.5 100 <7.01 Field Blank 332406913-0029 The results reported have been blank corrected as applicable. LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 04/15/2024 03:37 PM Printed: 04/15/2024 03:37 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3 LA Testing 5431 Industrial Drive Huntington Beach, CA 92649 Tel/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com / hblab@latesting.com LA Testing Order:332406913 Customer ID:CTEH99 Customer PO: Project ID:PROJ-032229 Attention:Noah Ambos Phone:(501) 454-1622 CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835 5120 North Shore Drive Received Date:04/15/2024 10:30 AM North Little Rock, AR 72118 Analysis Date:04/15/2024 Collected Date:04/13/2024 Project:PROJ-032229 (PROJ-032229) Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules, Revision 3, Issue 3, 6/14/2019 Sample Location Sample Date Volume (L)Fibers Fields LOD (fib/cc)Fibers/mm²Fibers/cc Notes Michael Chapman, Laboratory Manager or other Approved Signatory Analyst(s): Thanh Nguyen PCM 29 LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) = 0.33. Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650 Initial report from: 04/15/2024 03:37 PM Printed: 04/15/2024 03:37 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3