HomeMy WebLinkAboutPCM 04242024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332407807
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/25/2024 09:50 AM
North Little Rock, AR 72118 Analysis Date:04/25/2024
Collected Date:04/24/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0424AS001A 04/24/2024 1074.82 <5.5 100 0.0025 <7.01 <0.0025
332407807-0001
TUCA0424AS002A 04/24/2024 1068.81 <5.5 100 0.0025 <7.01 <0.0025
332407807-0002
TUCA0424AS003A 04/24/2024 1084.68 <5.5 100 0.0025 <7.01 <0.0025
332407807-0003
TUCA0424AS004A 04/24/2024 904.934 <5.5 100 0.0030 <7.01 <0.0030
332407807-0004
TUCA0424AS005A 04/24/2024 1063.04 <5.5 100 0.0025 <7.01 <0.0025
332407807-0005
TUCA0424AS006A 04/24/2024 1077.05 <5.5 100 0.0025 <7.01 <0.0025
332407807-0006
TUCA0424AS007A 04/24/2024 1070.78 <5.5 100 0.0025 <7.01 <0.0025
332407807-0007
TUCA0424AS008A 04/24/2024 1075.18 <5.5 100 0.0025 <7.01 <0.0025
332407807-0008
TUCA0424AS009A 04/24/2024 1077.23 <5.5 100 0.0025 <7.01 <0.0025
332407807-0009
TUCA0424AS010A 04/24/2024 1083.13 <5.5 100 0.0025 <7.01 <0.0025
332407807-0010
TUCA0424AS013A 04/24/2024 1097.96 <5.5 100 0.0025 <7.01 <0.0025
332407807-0011
TUCA0424AS014A 04/24/2024 770.706 <5.5 100 0.0035 <7.01 <0.0035
332407807-0012
TUCA0424AS017A 04/24/2024 685.216 <5.5 100 0.0039 <7.01 <0.0039
332407807-0013
TUCA0424AS018A 04/24/2024 1100.45 <5.5 100 0.0024 <7.01 <0.0024
332407807-0014
TUCA0424AS019A 04/24/2024 1093.64 <5.5 100 0.0025 <7.01 <0.0025
332407807-0015
TUCA0424AS021A 04/24/2024 1102.64 <5.5 100 0.0024 <7.01 <0.0024
332407807-0016
TUCA0424ASFB001A 04/24/2024 <5.5 100 <7.01 Field Blank
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/25/2024 01:10 PM
Printed: 04/25/2024 01:10 PM ASB_PCM_NoSig_0003_0001 Page 1 of 2
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332407807
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:04/25/2024 09:50 AM
North Little Rock, AR 72118 Analysis Date:04/25/2024
Collected Date:04/24/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332407807-0017
TUCA0424AS001B 04/24/2024 1049.04 <5.5 100 0.0026 <7.01 <0.0026
332407807-0018
TUCA0424AS002B 04/24/2024 1081.44 <5.5 100 0.0025 <7.01 <0.0025
332407807-0019
TUCA0424AS003B 04/24/2024 1083.13 <5.5 100 0.0025 <7.01 <0.0025
332407807-0020
TUCA0424AS004B 04/24/2024 1078.45 <5.5 100 0.0025 <7.01 <0.0025
332407807-0021
TUCA0424AS005B 04/24/2024 1077.3 <5.5 100 0.0025 <7.01 <0.0025
332407807-0022
TUCA0424AS006B 04/24/2024 1048.88 <5.5 100 0.0026 <7.01 <0.0026
332407807-0023
TUCA0424AS007B 04/24/2024 1064.37 <5.5 100 0.0025 <7.01 <0.0025
332407807-0024
TUCA0424AS008B 04/24/2024 1065.8 <5.5 100 0.0025 <7.01 <0.0025
332407807-0025
TUCA0424AS009B 04/24/2024 1068.04 <5.5 100 0.0025 <7.01 <0.0025
332407807-0026
TUCA0424AS010B 04/24/2024 1061.99 <5.5 100 0.0025 <7.01 <0.0025
332407807-0027
TUCA0424ASFB001B 04/24/2024 <5.5 100 <7.01 Field Blank
332407807-0028
The results reported have been blank corrected as applicable.
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Mindy Le PCM 28
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 04/25/2024 01:10 PM
Printed: 04/25/2024 01:10 PM ASB_PCM_NoSig_0003_0001 Page 2 of 2