HomeMy WebLinkAboutPCM 05042024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408467
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/06/2024 09:25 AM
North Little Rock, AR 72118 Analysis Date:05/06/2024
Collected Date:05/04/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0504AS001A 05/04/2024 687.4 <5.5 100 0.0039 <7.01 <0.0039
332408467-0001
TUCA0504AS002A 05/04/2024 1080.4 <5.5 100 0.0025 <7.01 <0.0025
332408467-0002
TUCA0504AS003A 05/04/2024 1061.5 <5.5 100 0.0025 <7.01 <0.0025
332408467-0003
TUCA0504AS004A 05/04/2024 895.8 <5.5 100 0.0030 <7.01 <0.0030
332408467-0004
TUCA0504AS005A 05/04/2024 1005.1 <5.5 100 0.0027 <7.01 <0.0027
332408467-0005
TUCA0504AS006A 05/04/2024 1074.6 <5.5 100 0.0025 <7.01 <0.0025
332408467-0006
TUCA0504AS007A 05/04/2024 1077.1 <5.5 100 0.0025 <7.01 <0.0025
332408467-0007
TUCA0504AS008A 05/04/2024 1075 <5.5 100 0.0025 <7.01 <0.0025
332408467-0008
TUCA0504AS009A 05/04/2024 1078 <5.5 100 0.0025 <7.01 <0.0025
332408467-0009
TUCA0504AS010A 05/04/2024 1077.7 <5.5 100 0.0025 <7.01 <0.0025
332408467-0010
TUCA0504AS013A 05/04/2024 1089 <5.5 100 0.0025 <7.01 <0.0025
332408467-0011
TUCA0504AS014A 05/04/2024 1054.3 <5.5 100 0.0026 <7.01 <0.0026
332408467-0012
TUCA0504AS015A 05/04/2024 1088.6 <5.5 100 0.0025 <7.01 <0.0025
332408467-0013
TUCA0504AS017A 05/04/2024 1074.3 <5.5 100 0.0025 <7.01 <0.0025
332408467-0014
TUCA0504AS018A 05/04/2024 1083.3 <5.5 100 0.0025 <7.01 <0.0025
332408467-0015
TUCA0504AS019A 05/04/2024 1026.6 <5.5 100 0.0026 <7.01 <0.0026
332408467-0016
TUCA0504AS021A 05/04/2024 1075.3 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/06/2024 02:43 PM
Printed: 05/06/2024 02:44 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408467
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/06/2024 09:25 AM
North Little Rock, AR 72118 Analysis Date:05/06/2024
Collected Date:05/04/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332408467-0017
TUCA0504ASFB001A 05/04/2024 <5.5 100 <7.01 Field Blank
332408467-0018
TUCA0504AS001B 05/04/2024 1031.8 <5.5 100 0.0026 <7.01 <0.0026
332408467-0019
TUCA0504AS002B 05/04/2024 998.2 <5.5 100 0.0027 <7.01 <0.0027
332408467-0020
TUCA0504AS003B 05/04/2024 1075.2 <5.5 100 0.0025 <7.01 <0.0025
332408467-0021
TUCA0504AS004B 05/04/2024 1076.8 <5.5 100 0.0025 <7.01 <0.0025
332408467-0022
TUCA0504AS005B 05/04/2024 982.6 <5.5 100 0.0027 <7.01 <0.0027
332408467-0023
TUCA0504AS006B 05/04/2024 1057.2 <5.5 100 0.0025 <7.01 <0.0025
332408467-0024
TUCA0504AS007B 05/04/2024 838.6 <5.5 100 0.0032 <7.01 <0.0032
332408467-0025
TUCA0504AS008B 05/04/2024 1081.7 <5.5 100 0.0025 <7.01 <0.0025
332408467-0026
TUCA0504AS009B 05/04/2024 1075.3 <5.5 100 0.0025 <7.01 <0.0025
332408467-0027
TUCA0504AS010B 05/04/2024 1041.1 <5.5 100 0.0026 <7.01 <0.0026
332408467-0028
TUCA0504ASFB001B 05/04/2024 <5.5 100 <7.01 Field Blank
332408467-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/06/2024 02:43 PM
Printed: 05/06/2024 02:44 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408467
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/06/2024 09:25 AM
North Little Rock, AR 72118 Analysis Date:05/06/2024
Collected Date:05/04/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/06/2024 02:43 PM
Printed: 05/06/2024 02:44 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3