HomeMy WebLinkAboutPCM 05092024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408802
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/10/2024 09:05 AM
North Little Rock, AR 72118 Analysis Date:05/10/2024
Collected Date:05/09/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0509AS001A 05/09/2024 1045 <5.5 100 0.0026 <7.01 <0.0026
332408802-0001
TUCA0509AS002A 05/09/2024 1075 <5.5 100 0.0025 <7.01 <0.0025
332408802-0002
TUCA0509AS003A 05/09/2024 1064.2 <5.5 100 0.0025 <7.01 <0.0025
332408802-0003
TUCA0509AS004A 05/09/2024 834 <5.5 100 0.0032 <7.01 <0.0032
332408802-0004
TUCA0509AS005A 05/09/2024 1008.5 <5.5 100 0.0027 <7.01 <0.0027
332408802-0005
TUCA0509AS006A 05/09/2024 1066.2 <5.5 100 0.0025 <7.01 <0.0025
332408802-0006
TUCA0509AS007A 05/09/2024 1066.7 <5.5 100 0.0025 <7.01 <0.0025
332408802-0007
TUCA0509AS008A 05/09/2024 1065.2 <5.5 100 0.0025 <7.01 <0.0025
332408802-0008
TUCA0509AS009A 05/09/2024 1063.4 <5.5 100 0.0025 <7.01 <0.0025
332408802-0009
TUCA0509AS010A 05/09/2024 1059.3 <5.5 100 0.0025 <7.01 <0.0025
332408802-0010
TUCA0509AS013A 05/09/2024 1078.5 <5.5 100 0.0025 <7.01 <0.0025
332408802-0011
TUCA0509AS014A 05/09/2024 1046.6 <5.5 100 0.0026 <7.01 <0.0026
332408802-0012
TUCA0509AS015A 05/09/2024 1082.3 <5.5 100 0.0025 <7.01 <0.0025
332408802-0013
TUCA0509AS017A 05/09/2024 1081.9 <5.5 100 0.0025 <7.01 <0.0025
332408802-0014
TUCA0509AS018A 05/09/2024 1073.6 <5.5 100 0.0025 <7.01 <0.0025
332408802-0015
TUCA0509AS019A 05/09/2024 1068.2 <5.5 100 0.0025 <7.01 <0.0025
332408802-0016
TUCA0509AS021A 05/09/2024 1084.6 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/10/2024 04:36 PM
Printed: 05/10/2024 04:36 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408802
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/10/2024 09:05 AM
North Little Rock, AR 72118 Analysis Date:05/10/2024
Collected Date:05/09/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332408802-0017
TUCA0509ASFB001A 05/09/2024 <5.5 100 <7.01 Field Blank
332408802-0018
TUCA0509AS001B 05/09/2024 1031.1 <5.5 100 0.0026 <7.01 <0.0026
332408802-0019
TUCA0509AS002B 05/09/2024 828.1 <5.5 100 0.0033 <7.01 <0.0033
332408802-0020
TUCA0509AS003B 05/09/2024 1078.5 <5.5 100 0.0025 <7.01 <0.0025
332408802-0021
TUCA0509AS004B 05/09/2024 1078.1 <5.5 100 0.0025 <7.01 <0.0025
332408802-0022
TUCA0509AS005B 05/09/2024 1073 <5.5 100 0.0025 <7.01 <0.0025
332408802-0023
TUCA0509AS006B 05/09/2024 1075.3 <5.5 100 0.0025 <7.01 <0.0025
332408802-0024
TUCA0509AS007B 05/09/2024 1050.1 <5.5 100 0.0026 <7.01 <0.0026
332408802-0025
TUCA0509AS008B 05/09/2024 1080 <5.5 100 0.0025 <7.01 <0.0025
332408802-0026
TUCA0509AS009B 05/09/2024 1078.5 <5.5 100 0.0025 <7.01 <0.0025
332408802-0027
TUCA0509AS010B 05/09/2024 1036.1 <5.5 100 0.0026 <7.01 <0.0026
332408802-0028
TUCA0509ASFB001B 05/09/2024 <5.5 100 <7.01 Field Blank
332408802-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/10/2024 04:36 PM
Printed: 05/10/2024 04:36 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408802
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Noah Ambos Phone:(501) 454-1622
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/10/2024 09:05 AM
North Little Rock, AR 72118 Analysis Date:05/10/2024
Collected Date:05/09/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Tony Salgado PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/10/2024 04:36 PM
Printed: 05/10/2024 04:36 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3