HomeMy WebLinkAboutPCM 05122024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408906
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Charles Connolly Phone:(832) 917-9742
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/13/2024 08:40 AM
North Little Rock, AR 72118 Analysis Date:05/13/2024
Collected Date:05/12/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0512AS001A 05/12/2024 1059.7 <5.5 100 0.0025 <7.01 <0.0025
332408906-0001
TUCA0512AS002A 05/12/2024 1057.8 <5.5 100 0.0025 <7.01 <0.0025
332408906-0002
TUCA0512AS003A 05/12/2024 1088.5 <5.5 100 0.0025 <7.01 <0.0025
332408906-0003
TUCA0512AS004A 05/12/2024 929.1 <5.5 100 0.0029 <7.01 <0.0029
332408906-0004
TUCA0512AS005A 05/12/2024 1073.4 <5.5 100 0.0025 <7.01 <0.0025
332408906-0005
TUCA0512AS006A 05/12/2024 1064.1 <5.5 100 0.0025 <7.01 <0.0025
332408906-0006
TUCA0512AS007A 05/12/2024 1065 <5.5 100 0.0025 <7.01 <0.0025
332408906-0007
TUCA0512AS008A 05/12/2024 1060.4 <5.5 100 0.0025 <7.01 <0.0025
332408906-0008
TUCA0512AS009A 05/12/2024 1066.6 <5.5 100 0.0025 <7.01 <0.0025
332408906-0009
TUCA0512AS010A 05/12/2024 1064.3 <5.5 100 0.0025 <7.01 <0.0025
332408906-0010
TUCA0512AS013A 05/12/2024 1082 <5.5 100 0.0025 <7.01 <0.0025
332408906-0011
TUCA0512AS014A 05/12/2024 1087.9 <5.5 100 0.0025 <7.01 <0.0025
332408906-0012
TUCA0512AS015A 05/12/2024 1090.8 <5.5 100 0.0025 <7.01 <0.0025
332408906-0013
TUCA0512AS017A 05/12/2024 1065.7 <5.5 100 0.0025 <7.01 <0.0025
332408906-0014
TUCA0512AS018A 05/12/2024 1083.2 <5.5 100 0.0025 <7.01 <0.0025
332408906-0015
TUCA0512AS019A 05/12/2024 1087.3 <5.5 100 0.0025 <7.01 <0.0025
332408906-0016
TUCA0512AS021A 05/12/2024 1086.3 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/13/2024 03:26 PM
Printed: 05/13/2024 03:26 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408906
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Charles Connolly Phone:(832) 917-9742
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/13/2024 08:40 AM
North Little Rock, AR 72118 Analysis Date:05/13/2024
Collected Date:05/12/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332408906-0017
TUCA0512ASFB001A 05/12/2024 <5.5 100 <7.01 Field Blank
332408906-0018
TUCA0512AS001B 05/12/2024 1065.3 <5.5 100 0.0025 <7.01 <0.0025
332408906-0019
TUCA0512AS002B 05/12/2024 882.1 <5.5 100 0.0031 <7.01 <0.0031
332408906-0020
TUCA0512AS003B 05/12/2024 1072.4 <5.5 100 0.0025 <7.01 <0.0025
332408906-0021
TUCA0512AS004B 05/12/2024 1068.3 <5.5 100 0.0025 <7.01 <0.0025
332408906-0022
TUCA0512AS005B 05/12/2024 1085.3 <5.5 100 0.0025 <7.01 <0.0025
332408906-0023
TUCA0512AS006B 05/12/2024 1080.6 <5.5 100 0.0025 <7.01 <0.0025
332408906-0024
TUCA0512AS007B 05/12/2024 891.9 <5.5 100 0.0030 <7.01 <0.0030
332408906-0025
TUCA0512AS008B 05/12/2024 1085.7 <5.5 100 0.0025 <7.01 <0.0025
332408906-0026
TUCA0512AS009B 05/12/2024 1089.5 <5.5 100 0.0025 <7.01 <0.0025
332408906-0027
TUCA0512AS010B 05/12/2024 1061 <5.5 100 0.0025 <7.01 <0.0025
332408906-0028
TUCA0512ASFB001B 05/12/2024 <5.5 100 <7.01 Field Blank
332408906-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/13/2024 03:26 PM
Printed: 05/13/2024 03:26 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332408906
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Charles Connolly Phone:(832) 917-9742
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/13/2024 08:40 AM
North Little Rock, AR 72118 Analysis Date:05/13/2024
Collected Date:05/12/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Thanh Nguyen PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/13/2024 03:26 PM
Printed: 05/13/2024 03:26 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3