HomeMy WebLinkAboutPCM 05182024LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332409387
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Charles Connolly Phone:(832) 917-9742
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/20/2024 09:10 AM
North Little Rock, AR 72118 Analysis Date:05/20/2024
Collected Date:05/18/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
TUCA0518AS001A 05/18/2024 1064.9 <5.5 100 0.0025 <7.01 <0.0025
332409387-0001
TUCA0518AS002A 05/18/2024 1065 <5.5 100 0.0025 <7.01 <0.0025
332409387-0002
TUCA0518AS003A 05/18/2024 1053.7 <5.5 100 0.0026 <7.01 <0.0026
332409387-0003
TUCA0518AS004A 05/18/2024 964.6 <5.5 100 0.0028 <7.01 <0.0028
332409387-0004
TUCA0518AS005A 05/18/2024 1067.8 <5.5 100 0.0025 <7.01 <0.0025
332409387-0005
TUCA0518AS006A 05/18/2024 1062.4 <5.5 100 0.0025 <7.01 <0.0025
332409387-0006
TUCA0518AS007A 05/18/2024 1061.8 <5.5 100 0.0025 <7.01 <0.0025
332409387-0007
TUCA0518AS008A 05/18/2024 1068.9 <5.5 100 0.0025 <7.01 <0.0025
332409387-0008
TUCA0518AS009A 05/18/2024 1066.1 <5.5 100 0.0025 <7.01 <0.0025
332409387-0009
TUCA0518AS010A 05/18/2024 1064.3 <5.5 100 0.0025 <7.01 <0.0025
332409387-0010
TUCA0518AS013A 05/18/2024 1085.7 <5.5 100 0.0025 <7.01 <0.0025
332409387-0011
TUCA0518AS014A 05/18/2024 1091.4 <5.5 100 0.0025 <7.01 <0.0025
332409387-0012
TUCA0518AS015A 05/18/2024 1085.6 <5.5 100 0.0025 <7.01 <0.0025
332409387-0013
TUCA0518AS017A 05/18/2024 1083.8 <5.5 100 0.0025 <7.01 <0.0025
332409387-0014
TUCA0518AS018A 05/18/2024 1076.6 <5.5 100 0.0025 <7.01 <0.0025
332409387-0015
TUCA0518AS019A 05/18/2024 1087.7 <5.5 100 0.0025 <7.01 <0.0025
332409387-0016
TUCA0518AS021A 05/18/2024 1078 <5.5 100 0.0025 <7.01 <0.0025
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/20/2024 01:38 PM
Printed: 05/20/2024 01:38 PM ASB_PCM_NoSig_0003_0001 Page 1 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332409387
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Charles Connolly Phone:(832) 917-9742
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/20/2024 09:10 AM
North Little Rock, AR 72118 Analysis Date:05/20/2024
Collected Date:05/18/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
332409387-0017
TUCA0518ASFB001A 05/18/2024 <5.5 100 <7.01 Field Blank
332409387-0018
TUCA0518AS001B 05/18/2024 1082.7 <5.5 100 0.0025 <7.01 <0.0025
332409387-0019
TUCA0518AS002B 05/18/2024 632.1 <5.5 100 0.0043 <7.01 <0.0043
332409387-0020
TUCA0518AS003B 05/18/2024 790.1 <5.5 100 0.0034 <7.01 <0.0034
332409387-0021
TUCA0518AS004B 05/18/2024 1076.4 <5.5 100 0.0025 <7.01 <0.0025
332409387-0022
TUCA0518AS005B 05/18/2024 1078.9 <5.5 100 0.0025 <7.01 <0.0025
332409387-0023
TUCA0518AS006B 05/18/2024 1084.1 <5.5 100 0.0025 <7.01 <0.0025
332409387-0024
TUCA0518AS007B 05/18/2024 839 <5.5 100 0.0032 <7.01 <0.0032
332409387-0025
TUCA0518AS008B 05/18/2024 1083.2 <5.5 100 0.0025 <7.01 <0.0025
332409387-0026
TUCA0518AS009B 05/18/2024 1081.8 <5.5 100 0.0025 <7.01 <0.0025
332409387-0027
TUCA0518AS010B 05/18/2024 1072.8 <5.5 100 0.0025 <7.01 <0.0025
332409387-0028
TUCA0518ASFB001B 05/18/2024 <5.5 100 <7.01 Field Blank
332409387-0029
The results reported have been blank corrected as applicable.
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/20/2024 01:38 PM
Printed: 05/20/2024 01:38 PM ASB_PCM_NoSig_0003_0001 Page 2 of 3
LA Testing
5431 Industrial Drive Huntington Beach, CA 92649
Tel/Fax: (714) 828-4999 / (714) 828-4944
http://www.LATesting.com / hblab@latesting.com
LA Testing Order:332409387
Customer ID:CTEH99
Customer PO:
Project ID:PROJ-032229
Attention:Charles Connolly Phone:(832) 917-9742
CTEH Center for Toxicology & Env. Health Fax:(501) 614-2835
5120 North Shore Drive Received Date:05/20/2024 09:10 AM
North Little Rock, AR 72118 Analysis Date:05/20/2024
Collected Date:05/18/2024
Project:PROJ-032229 (PROJ-032229)
Test Report: Fiber Count by Phase Contrast Microscopy (PCM), NIOSH 7400 Method - A Rules,
Revision 3, Issue 3, 6/14/2019
Sample Location Sample Date Volume (L)Fibers Fields
LOD
(fib/cc)Fibers/mm²Fibers/cc Notes
Michael Chapman, Laboratory Manager
or other Approved Signatory
Analyst(s):
Kaylin Luciani PCM 29
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except
in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the
field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Limit of
detection is 7 fibers/mm². Fiber counts outside the recommended fiber density range of the method (100-1300 f/mm²) have greater than optimal variability and are probably biased. Field blank results, when available, are
used to blank correct results. NIOSH 7400 requires field blanks be submitted at a rate of 10%, with a minimum of 2 per set. Measurement of uncertainty available upon request. The results in this report meet all
requirements of the NELAC standards unless otherwise noted. Intra-laboratory Sr values: 5-20 fibers = 0.25, 21-50 fibers = 0.22, 51-100 fibers = 0.18. Inter-laboratory Sr values (Average of EMSL round robin data) =
0.33.
Samples analyzed by LA Testing Huntington Beach, CA AIHA LAP, LLC-IHLAP Accredited #101650
Initial report from: 05/20/2024 01:38 PM
Printed: 05/20/2024 01:38 PM ASB_PCM_NoSig_0003_0001 Page 3 of 3