Loading...
HomeMy WebLinkAboutMYRTLE AVE S 180 09/17/2018BUILDING PERMIT NUMBER: ASSESSOR'S PARCEL NUMBER: DEVELOPMENT AREA:. CITY OF TUSTIN Community Development Department - Building Division 300 Centennial Way, Tustin CA 92780 Building Counter (714) 573-3131 - Inspection Recorder (714) 573-3141 COM -BR -2018-00234 401-541-06 NO COMMERCIAL DISTRIC PROPERTY OWNER: BRENDA NIMOTA 180 MYRTLE TUSTIN, CA 92780 CONTRACTOR SUNLIFE RESIDENTIAL CONTRACTING 1 INC 19800 MACARTHUR BLVD 300, IRVINE, CA 92612 .(949)514-8005:. JOB DESCRIPTION: PV SOLAR 26PANELS, 7.20KW ADDRESS: 180 MYRTLE AV ISSUED BY: KIMBOND DATE ISSUED: 09/17/2018 OCCUPANT LOAD: O.C.F.A Number CONSTRUCTION TYPE: RESIDENTIAL SQ.FT OCCUPANY GROUP: INDUSTRIAL SQFT: 0 GARAGE SQ FT: 0 COMMERCIAL SQ IT 0 WAREHOUSE SQ FT: 0 ROOF SQ FT: 0 OFFICE SQ FT: 0 CBC EDITION: 2013 NUMBER OF UNITS: TENANT IMPR SQ FT: 0 BUILDER VALUATION: NUMBER OF SEATS: NUMBER OF STORIES: VALUATION $17,000.00 FEE SUMMARY BUILDING PERMIT FEF, $222.59 BUILDING PLAN CHECK FEE $155.81 PERMIT ISSUANCE FEE - $35.00 BUILDING PLANNING INSPECTION FEE - $44.52 PLANNING PLAN CHECK FEE $31.16 SB 1473 CTPY FEE $0.10 BUILDING SEISMIC STRUCTURAL FEE - $2.21 STATE BUILDING 1473 FEE $0.90 WRRP APPI ICATION FEE $50.00 RESIDENTIAL TOTAL FEES: $492.29 LICENSED CONTRACTOR DECLARATION: I hereby affirm that I am a licensed Contractor under the provisions of chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code, and my license LICENSE NUMBER: 1016224 LICENSE CLASS: CIO - Electrical Contractor, B - General Building Contractor Expires Date: 07/31/2020 OWNER BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason (Section 7031.5, Business Professions Code: Any City of county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions code] or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500.00). _ I as owner of the property, or my employees with wages as their sole compensation, will do the work and the stmeture is not intended or offered for sale (Section 7044, Business & Professions Code: the Conhactor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for purposes of sale). I, as owner of the property, am exclusively contracting with licensed contractors to commuct the project (Section 7044, Business & Professions Code: The Contractor's License Taw does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) license pursuant to the Contractor's License Law). _ I am exempt under Section Business & Professions Code for the following reason(s): Owner Signature: Date: WORKER'S COMPENSATION DECLARATION: _ I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain Worker's Compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My Worker's Compensation insurance carrier and Policy Number are: POLICY NUMBER: 9164243 COMPANY: STATE FUND (This section need not be completed if the permit is for one hundred dollars ($100) or less). _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California, and I agree that if I should become subject to the Worker's Compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: Failure to secure Worker's Compensation coverage is unlawtid, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000) in addition to the cost of compensation, damages as provided for in Section (3700) ofthe Labor Code, interest and attorney fees. IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. Each person upon whose behalf this application is made and each person at whose request and for whose benefit work is performed under or pursuant to any permit issues as a result of this application agrees m, and shall, indemnify and hold harmless the City oftustin, its officers, agents and employees in accordance with the provisions of Chapter 2 of the Uniform Administrative Code. I agree not to occupy or allow occupancy of any building authorized by this permit until final inspection has been received. I certify that I have read this application and state that the above information is correct. I agree to comply with all City and State laws relating to the building construction, and hereby authorize representative of the City to enter upon the above mentioned property for inspection purposes. Sainum e of Owner. Contractor. or Authorized Anent Date ***BUILDING PERMITS ARE SUBJECT TO EXPIRATION IF WORK 1S NOT COMMENCED W111ILN 180 DAYS AFTER DATE OF ISSUANCE OR IF WORK IS SUSPENDED FOR 180 DAYS*** Elpr Microinverter � TJ oposed wwk omabtw Map uealca,. ant,aasabYalasya One d Thai M s, X aPP4ca I II SolatMpdule �l T^'�'°P°�dw«” ^a.a«aaMan.nriij. xwaa»aana,r �I y. Da°Ignated Cusutal cn rNalln nr dylrlcl, Condult y 'Rat ;n.,,aetl",Klanartvft, w*eKIWV °unou*,ja In Nrrma .PP'W dwarwaa a Janata, scab, MJ Wphl, p°oa ' W uaa of a mw bulltlinp or structure real'cmap b eal$ft bu**V and tbu°baea anal aM -`"-' Fire setback .urroundmp aaninp. Approved by N3 IJale; Note: This installation will provide verification at time of inspection that 2016 CRC sections 314/315 T�CRMCT ; (smoke and CO detectors) are in compliance. wr-.3R _2n IS -o6Z'4i " ARRAY SKIRT Skirt End Ca s Arra Ski 7 V 2 7�0 OUNDING MID CLUMP D CLAMP RAILOUND LUGG BETWEEN TWO SPLICES OF RAILS AT THE END OF THE RAIL TO GO TO THE J -BOX E COPPER EGCULES GROUNDING AND CLAMPING DETAIL UL 2703 AND UL467 CERTIFIED rGa Note: Arrhoy 1'panlsi have Ir C �0a C1 1 0 ❑a (aa ❑a ❑a ,ftJ/B f(❑--�b�ab]ab�b a;b abb"^? I ° � PHOTOVOLTAIC ARRAY 3' fire setback /133 3' fire setback _ 154 (26) Hyundai 300 tN Solar Modules (HiS=S300Ro) I❑c �j❑c Rl❑c L❑C 3' fire MPLIA� (26) Enphase Energy Microinverters (IQ6PLUS-72-x-US (240 [SI1]) Clc ❑`c Cqy o Justin ?_ "r as Jac - on Jun ry Development Deparpnenl UNIT INDEX edfZle of AWopnetensaa se back Addaae: l S. any violation laws or ordinances. One set must be kept on the j@ D tion. MSP (N) 200A Main Iweni PV S } ,,, _ N G PV (N) PV Sub Pa:T�usgn p,e���a Solar PV Arra 1 Maforlcal Rio lea to aM1uciwa(s) t NJ YMuded In bw C1lymuciurN°)1Qat�NJ YMua°a Iniw CMv yJ/B Ytrup se sl SyM Repo b OYES 4NO y(N) Junction Bo14- Hyundai 300W Modules fl0°n°' 4-IQ6 Plus Microinverters AC (N) AC Disconn�e th waa«ntwa woratn w,tupt,ywcan,,,,g„syo awP.roMmIXm Pitch: 34 Deg Elpr Microinverter � TJ oposed wwk omabtw Map uealca,. ant,aasabYalasya One d Thai M s, X aPP4ca I II SolatMpdule �l T^'�'°P°�dw«” ^a.a«aaMan.nriij. xwaa»aana,r �I y. Da°Ignated Cusutal cn rNalln nr dylrlcl, Condult y 'Rat ;n.,,aetl",Klanartvft, w*eKIWV °unou*,ja In Nrrma .PP'W dwarwaa a Janata, scab, MJ Wphl, p°oa ' W uaa of a mw bulltlinp or structure real'cmap b eal$ft bu**V and tbu°baea anal aM -`"-' Fire setback .urroundmp aaninp. Approved by N3 IJale; Note: This installation will provide verification at time of inspection that 2016 CRC sections 314/315 T�CRMCT ; (smoke and CO detectors) are in compliance. wr-.3R _2n IS -o6Z'4i " ARRAY SKIRT Skirt End Ca s Arra Ski 7 V 2 7�0 OUNDING MID CLUMP D CLAMP RAILOUND LUGG BETWEEN TWO SPLICES OF RAILS AT THE END OF THE RAIL TO GO TO THE J -BOX E COPPER EGCULES GROUNDING AND CLAMPING DETAIL UL 2703 AND UL467 CERTIFIED rGa Note: Arrhoy 1'panlsi have Ir C �0a C1 1 0 ❑a (aa ❑a ❑a ,ftJ/B f(❑--�b�ab]ab�b a;b abb"^? I ° Solar PV Array 2 4- Hyundai 30OW Modules 4-IQ6 Plus Microinverters Pitch: 34 Deg Solar PV Array 3 4- Hyundai 30OW Modules 4-IQ6 Plus Microinverters Pitch: 34 Dea FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 3 1/2" HEIGHT, THEN UNDER THE EAVE TO MAIN SERVICE PANEL - c I `a I c e ccc� Arra Skirt I x T fire setback Arra Skirt � T fire setback /132 3' fire setback /133 3' fire setback _ 154 c❑ I c ❑ I� c ❑ !F C ❑.._I 3' fir setback - I❑c �j❑c Rl❑c L❑C 3' fire MPLIA� o Clc ❑`c do ❑C as Jac 3 se back Solar PV Array 2 4- Hyundai 30OW Modules 4-IQ6 Plus Microinverters Pitch: 34 Deg Solar PV Array 3 4- Hyundai 30OW Modules 4-IQ6 Plus Microinverters Pitch: 34 Dea FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 3 1/2" HEIGHT, THEN UNDER THE EAVE TO MAIN SERVICE PANEL - c I `a I c e ccc� Arra Skirt I x T fire setback Arra Skirt � Solar PV Array 4 4- Hyundai 30OW Modules Q REVIEWED FOR N DEC MPLIA� 4-IQ6 Plus Microinverters Pitch: 5 Deg Approval of these plat Speci tion Shall n approv< Orientation 90 Dep be construed to be a er of any Federal, it for, St t owed �� any violation laws or ordinances. One set must be kept on the j@ D tion. N G W 2nd St WILLDAN E SCALE E- ROOF PLAN Drawn By: David D. N°. RaHa /Issue IDula CONTRACTOR I.... 425 West La Cadena or,, Ste 9, Riverside; CA 92501 (951)662-8769 Brenda Nimote, S Myrtly Ave, TI CA 927&0 w ]/26/18 P51NJiCAT.EC PV SYSTEM GENERAL NOTES 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER, 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO, AND CITY INSPECTORS AS NEEDED. 6. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS VOER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WHITSANDING THE EXTRA WEIGHT. 9, IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE SIRE SIZE. FINAL DRAWINGS WILL BE RED -LINED AND UPDATED AS APPRPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. 11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK PHOTOVOLTAIC NOTES 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED, 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5, REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSIC 11 DAMAGE. Cl 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV O JTPUT - BU CIRCUITS OVER 150V TO GROUND SHALL NOT BE�Th� AC GROUNDING ACCESSIBLE TO OTHER THAN QUALIFIED PERSON a WHTL ` ENERGIZED. tn( SYSTEM SIZE: DC STC: 7.80 KW 15, EQUIPMENT GROUND CONDUCTOR REQUIRED IN 6. INVERTER IS EQUIPED W1 INTEGRATED GFDI, TH SaIt.EY il+ i15 PROVIDING GROUND FAULT PROTECTION ne,,rl sioYl f', 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEP�En i MOUNTING SYSTEM: UNIRAC 13LQ SING DIV' Residential buildings (Group R occupant es) undergoir BOND BOTH ENDS OF RACEWAYS 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED Yp%,rmit or be RECOGNIZED ELECTRICAL TESTING LABORATORY Racy prgvIsi, APPROVED BY THE DEPARTMENT. state or FE 11, CONDUITS SHOULD BE PAINTED TO MATCH ROOF AND WALL COLORS 12. ALL WORK SHALL BE IN ACCORD WITH THE 2016 [BC 201 CEG AND 2016 NEC WITH SPECIAL EMPHASIS ON AR ISG 69 13. THE OUTPUT OF A UTILITY INTERACTIVE -INVERT BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING t !!e _ SHEET INDEX =1 ROdF PLAN 2 SINGLE LIN . ikAGIkAM - S f it 5,e 8ICATTI AtN14 T LAYOUT Tt i 1W1,4059 , ATA SHEET SHEET COMMUNITY IFICATION RACKING W TA SHEET RACK CERTIFICATION VftACHMENr DATA INSTALLER MYERS ELECTRIC COMPANY 425 West La Cadena Dr., Ste 9, Riverside, CA 92501 (951)662-8769 www.rnyerselectr[caIrepar.com License #972274 2018 S VERNAME: DAVID D. DATE: 7126118 MEANS AS PER 230.82(6) THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL BE IN ACCORDANCE WITH THE MOST RECENT CPC, CMC, 14. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED 2016 CEC, 2016 CRC, 2016 CBC AND 2016 NEC. AS AMMENDED BY THE TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, LOCAL AHJ, STRUCTUAL CONNECTIONS SHALL BE TO 2016 IBC. AC GROUNDING PHOTOVOLTAIC SYSTEM SUMMARY RECEIVED AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC 690.47(0) AND SIZED AS PER SEC 250.166 SYSTEM SIZE: DC STC: 7.80 KW 15, EQUIPMENT GROUND CONDUCTOR REQUIRED IN SYSTEM SIZE: AC CEC: 6.88 KW SMOKE & CARBON MO OXID T" 201 RACEWAYS SIZED PER CEC 260 SOLAR MODULES: (26) HYUNDAI, HIS-S300RG TO BE INSTALLED AND INS ED MICRO INVERTERS: (26) IQ6PLUS-72-x-US (240V) [SI1] 16, PER ART 250.92, NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. MOUNTING SYSTEM: UNIRAC 13LQ SING DIV' Residential buildings (Group R occupant es) undergoir BOND BOTH ENDS OF RACEWAYS ELECTRICAL INFORMATION: additions or improvements, shall replace non-compliar NEW UPGRADED plumbing fixtures with water -conserving fixtures as follow MAIN SERVICE PANEL BUS SIZE: 200A > Water Closets 1.6 GPF (gallons per flush) MAIN SERVICE BREAKER SIZE: 200A > Faucets (ail interior) 2.2 GPM (gallons per minute) > Urinals 1.0 GPF PROJECT NAME: BRENDA NIMOTA CGBSC see.301.1.1 & referenced Civil Code See.1101.1 ADDRESS. 180 S MYRTLE AVE, TUSTIN, CA 92780 BUILDING INFORMATION: TWO STORY HOUSE wNE.t Al C(�' CONSTRUCTION TYPE: V B APN: 401-541-t OCCUPANCY: R - ROOF: COMP SITIONINGLE EV1 0? 71 E COMPLIANC °:-evlewed kl by: w�a _ :=- ate: 74 f ;t Y Approval of these plans & specifications shall nc ig be construed to be a permit for, or an approval c j any violation of any Federal, State, County or CH laws or ordinances. One set of approved plans VICINITY MAP SATELLITE VIEW must be �t on the job urpil completion: __. SCALE:NTS